• 제목/요약/키워드: large current conductor

검색결과 74건 처리시간 0.019초

Ti Mesh 처리 촉매전극을 이용한 고체고분자 전해질 전기분해 특성연구 (A Study on the PEM Electrolysis Characteristics Using Ti Mesh Coated with Electrocatalysts)

  • 심규성;김연순;김종원;한상도
    • 한국수소및신에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.29-37
    • /
    • 1996
  • Alkaline water electrolysis has been commercialized as the only large-scale method for a long time to produce hydrogen and the technology is superior to other methods such as photochemical, thermochemical water splitting, and thermal decomposition method in view of efficiency and related technical problem. However, such conventional electrolyzer do not have high electric efficiency and productivity to apply to large scale hydrogen production for energy or chemical feedstocks. Solid polymer electrolyte water electrolysis using a perfluorocation exchange membrane as an $H^+$ ion conductor is considered to be a promising method, because of capability for operating at high current densities and low cell voltages. So, this is a good technology for the storage of electricity generated by photovoltaic power plants, wind generators and other energy conversion systems. One of the most important R&D topics in electrolyser is how to minimize cell voltage and maximize current density in order to increase the productivity of the electrolyzer. A commercialized technology is the hot press method which the film type electrocatalyst is hot-pressed to soild polymer membrane in order to eliminate the contact resistance. Various technologies, electrocatalyst formed over Nafion membrane surface by means of nonelectrolytic plating process, porous sintered metal(titanium powder) or titanium mesh coated with electrocatalyst, have been studied for preparation of membrane-electrocatalyst composites. In this study some experiments have been conducted at a solid polymer electrolyte water electrolyzer, which consisted of single cell stack with an electrode area of $25cm^2$ in a unipolar arrangement using titanium mesh coated with electrocatalyst.

  • PDF

발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석 (Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.213-218
    • /
    • 2017
  • 발전소에서 전기를 생산 및 공급하기 위하여 고전압 전력 시스템이 동작하고 있다. 고전압 시스템은 저전압 시스템과 비교하여 구조가 복잡하고, 규모가 크고, 가격이 비쌀 뿐만 아니라. 사고 발생시 저압 시스템을 포함하는 대부분의 설비들에 정전사고가 발생하여 막대한 경제적 손실을 초래한다. 설계부터 시공 및 관리를 더욱 철저히 해야 한다. 설치환경 및 사용 조건 부하량 등에 따라 차이가 있겠지만, 증설과정, 부적절한 설계 등으로 인하여 케이블의 단면적이 부족할 경우가 발생하며, 운전 전류에 의하여 초과된 허용온도는 케이블의 열화 상태를 초래한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korean Western Power Co. Ltd.)에 설치하여 활선 케이블을 진단하였다. 이 논문에서 우리는 케이블의 부하전류를 측정하고, 측정된 부하전류에 의한 온도 특성을 예측 연구한 결과를 제시한다. 이 온도 값을 해석하여 케이블의 열화에 미치는 영향을 예측할 수 있다.

Transparent Conductors for Photoelectric Devices

  • Kim, Joondong;Patel, Malkeshkumar;Kim, Hong-Sik;Yun, Ju-Hyung;Kim, Hyunki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.87.2-87.2
    • /
    • 2015
  • Transparent conductors are commonly used in photoelectric devices, where the electric energy converts to light energy or vice versa. Energy consumption devices, such as LEDs, Displays, Lighting devices use the electrical energy to generate light by carrier recombination. Meanwhile, solar cell is the only device to generate electric energy from the incident photon. Most photoelectric devices require a transparent electrode to pass the light in or out from a device. Beyond the passive role, transparent conductors can be employed to form Schottky junction or heterojunction to establish a rectifying current flow. Transparent conductor-embedded heterojunction device provides significant advantages of transparent electrode formation, no need for intentional doping process, and enhanced light-reactive surface area. Herein, we present versatile applications of transparent conductors, such as NiO, ZnO, ITO in photoelectric devices of solar cells and photodetectors for high-performing UV or IR detection. Moreover, we also introduce the growth of transparent ITO nanowires by sputtering methods for large scale application.

  • PDF

전력회사 계통에 22kV급 초전도 케이블 도입을 위한 적용 개소 고찰 (A Study on the Application of 22kV class Superconducting Cable in Utility Network)

  • 김종율;윤재영;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.20-29
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the need of underground transmission system is increasing gradually. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable can carry very high current densities with strongly reduced conductor loss and allow high power transmission at reduced voltage. Therefore HTS cable can transfer more power to be moved in existing ducts, which means very large economical and environmental benefits. A development project for a 22kV class HTS cable is ongoing at a research centers, and the cable manufacturer in Korea. In this paper, we carried out investigation for application of 22kV class HTS cable in Korean utility networks. The results show that the HTS cable is applicable to replace IPB in pumping-up power plant, withdrawal line in distributed generation, withdrawal line in complex power plant, and conventional under ground cable. Finally, as the cost of HTS wire and refrigeration drops, the technical and economical potential of HTS cable is evaluated positively.

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

진상각 제어에 따른 AC 서보 모터의 토오크 특성에 관한 연구 (A study on the torque characteristic of AC servo system by phase advance control)

  • 임윤택;손명훈;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.393-400
    • /
    • 1992
  • The DC(Direct-Current) servo motor has widely used for many application areas, FA(Factory Automation), OA(Office Automation) and home applications. But DC servo motor needs periodical inspection because it has brush and commutator. Recently, AC servo motor has expanded it's application areas due to for the development of the power semi-conductor and control technology. But it has large torque ripple for it's small number of commutation. And it also has cogging torque due to permanent magenet rotor. Therefore it can't run balence rotarion. Many torque ripple reduction methods are published. In this paper, phase advanced method adopted for torque ripple reduction of AC servo motor. In this research, AC servo motor torque characteristic variation surveied under the phase advance control through the computer simulation. Under the simulation, the load inertia varied from 0.0001[Kg.m$^{2}$] to 0.0314[Kg.m$^{2}$]. The result os nonlinear simulation, torque and speed ripple of AC servo motor under the phase advance control reduced approximately 50[%] and 10[%]. And maximum torque of AC servo motor under phase advance control condition increased about 5[%] as compare with fixed switching time.

  • PDF

고온초전도 변압기 및 부싱의 절연설계 (The Insulation Design of HTS Transformer and Bushing)

  • 천현권;최재형;방만식;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.12-15
    • /
    • 2010
  • Important key technologies of high-$T_c$ superconducting (HTS) transformer may include the HTS wire technology, bushing technology, cooling technology, AC loss, reduction technology, large current technology, and cryogenic temperature insulation technology. From among others, the cryogenic temperature insulation technology may be specifically a core technology for ensuring reliability for the smaller size, stability, economic efficiency, and power supply of a transformer. Therefore, the electric insulation technology of a superconducting transformer should be prerequisite. Such relevant studies are ongoing, but still, they are very insufficient for establishing the cryogenic insulation technology as of yet. Therefore, this paper simulated HTS transformer applied with continuous transposed conductor (CTC), which has been studied as a way of reducing AC loss. Also, the paper analyzed the insulation configuration of HTS transformer and bushing, and, accordingly, reviewed various characteristics of insulation breakdown out of liquid nitrogen. Thus, the paper constituted insulation database, and it is going to design the insulation of a transmission class HTS transformer and bushing.

펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성 (Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils)

  • 추용;요네가와;김영옥;이현정;박갑래;오영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

KSTAR PF 초전도자석의 크기 및 재료에 따른 결합손실 특성 분석 (Analysis of Coupling Loss with Size and Material in the KSTAR PF Superconducting Coils)

  • 이현정;추용;이상일;박영민;박현택;오영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.1-5
    • /
    • 2009
  • It is important to predict AC loss in $Nb_3Sn$ and NbTi cable-in-conduit-conductor (CICC) reliably for the design and operation of large superconducting coils. The hysteresis loss in the superconducting filaments and coupling loss within strands and among strands in a cable or composite are dominant ac losses in superconducting magnets. The coupling loss in a superconductor can be characterized by identifying the coupling constant time $n{\tau}$. To reduce the coupling loss, all the strands (superconductor and Cu) in KSTAR (Korea Superconducting Tokamak Advance Research) are chromium plated with thickness of $l{\pm}0.5{\mu}m$. The ac losses of PF1, PF5 and PF6 coils has been measured by calorimetric method while applying trapezoidal current pulses with various ramp rate from 0.5 kA/s to 2 kA/s. The coupling time constants for $Nb_3Sn$ coils are $25{\sim}55$ ms and the values are not co-related with the coil size, the time constants for NbTi coil is 30 ms.

Evaluation of electromechanical properties in REBCO CC tapes under transverse compression using anvil test method

  • Diaz, Mark Angelo;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.57-61
    • /
    • 2022
  • One of the major applications of REBCO coated conductor (CC) tapes is in superconducting magnets or coils that are designed for high magnet fields. For such applications, the CC tapes were exposed to a high level of stresses which includes uniaxial tensile or transverse compressive stresses resulting from a large magnetic field. Thus, CC tapes should endure such mechanical load or deformation that can influence their electromechanical performance during manufacturing, cool-down, and operation. It has been reported that the main cause of critical current (Ic) degradation in CC tapes utilized in coil windings for superconducting magnets was the delamination due to transversely applied stresses. In most high-magnetic-field applications, the operating limits of the CC tapes will likely be imposed by the electromechanical properties together with its Ic dependence on temperature and magnetic field. In this study, we examined the influence of the transverse compressive stress on the Ic degradation behaviors in various commercially available CC tapes which is important for magnet design Four differently processed REBCO CC tapes were adopted to examine their Ic degradation behaviors under transverse compression using an anvil test method and a newly developed instantaneous Ic measurement system. As a result, all REBCO CC tapes adopted showed robustness against transverse compressive stresses for REBCO coils, notably at transverse compressive stresses until 250 MPa. When the applied stress further increased, different Ic degradation behaviors were observed depending on the sample. Among them, the one that was fabricated by the IBAD/MOCVD process showed the highest compressive stress tolerance.