수술용 로봇 햅틱 시스템 구성을 위한 저관성 마스터 장치 핸들부 개발 (Development of Low-inertia Master device for Haptic system configuration of surgical robot)

  • 강병호;윤성민;이민철;김지언
    • 로봇학회논문지
    • /
    • 제7권4호
    • /
    • pp.267-275
    • /
    • 2012
  • When using commercialized robot assisted laparoscopic, surgeon has met some problems to depend only on image of the surgical field. To solve it, there were various researches. The previous study showed that it is possible to estimate the operation force on the commercialized instrument inside patient without sensors. To apply the estimated force to a haptic master console for the laparoscopy surgical robot system, the light haptic master console should be designed. This paper suggests the design of lighter master console handle to reduce a weight of the console whose structure can match with the joint and DOF of an instrument. A cable-conduit mechanism is designed to make light structure to perform a delicate manipulation. The cable-conduit mechanism removes the weight and inertia of link caused by haptic actuator and encoder which is separated from handle link of a manipulator.

로봇 수술을 위한 3차원 구조계산의 필요성 조사 (Research of 3D Information processing for Robot Surgery)

  • 정재은;최석윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.43-50
    • /
    • 2009
  • Geometry calculation Using Abdominal internal organ image from traditional laparoscopy or robotic surgery system we can make depth informations through measured 3D structure informations is very helpful to doctors, depth information is mare useful then others that use traditional laparoscopy or robotic surgery system to many doctors. however, traditional method are incomplete. less experienced doctors make much mare prohability of mistake. Hence, 3D information of organ is very helpful to the less experienced doctors. it will be greate role of reducing medical accidents and surgical time. We can get 3D informations using geometrical calculation method in robotic surgical system. also suggested method is needed in traditional surgical method without the need to create a new system, finally, We can get 3D information from traditional system without any new system, it take advantage in cost and create high efficiency. mare information will provided to many doctors.

  • PDF

복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구 (Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument)

  • 김지언;이민철;이태경;최승욱;박민규
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

복강경 수술 로봇의 힘 반향을 위한 임피던스 모델 기반의 양방향 제어 (Impedance Model based Bilateral Control for Force reflection of a Laparoscopic Surgery Robot)

  • 윤성민;김원재;이민철
    • 제어로봇시스템학회논문지
    • /
    • 제20권8호
    • /
    • pp.801-806
    • /
    • 2014
  • LAS (Laparoscopy Assisted Surgery) has been substituted alternatively for traditional open surgery. However, when using a commercialized robot assisted laparoscopic such as Da Vinci, surgeons have encountered some problems due to having to depend only on information by visual feedback. To solve this problem, a haptic function is required. In order to realize the haptic teleoperation system, a force feedback and bilateral control system are needed. Previous research showed that the perturbation value estimated by a SPO (Sliding Perturbation Observer) followed a reaction force that loaded on the surgical robot instrument. Thus, in this paper, the force feedback problem of surgical robots is solved through the reaction force estimation method. This paper then introduces the possibility of the haptic function realization of a laparoscopic surgery robot using a bilateral control system. For bilateral control, the master uses an impedance control and the slave uses a SMC (Sliding Mode Control). The experiment results show that a torque and force sensorless teleoperation system can be implemented using a bilateral control structure.

Current Issues in Minimally Invasive Esophagectomy

  • Na, Kwon Joong;Kang, Chang Hyun
    • Journal of Chest Surgery
    • /
    • 제53권4호
    • /
    • pp.152-159
    • /
    • 2020
  • Minimally invasive esophagectomy (MIE) was first introduced in the 1990s. Currently, it is a widely accepted surgical approach for the treatment of esophageal cancer, as it is an oncologically sound procedure; its advantages when compared to open procedures, including reduction in postoperative complications, reduction in the length of hospital stay, and improvement in quality of life, are well documented. However, debates are still ongoing about the safety and efficacy of MIE. The present review focuses on some of the current issues related to conventional MIE and robot-assisted MIE based on evidence from the current literature.

Design of a Compact Laparoscopic Assistant Robot;KaLAR

  • Lee, Yun-Ju;Kim, Jona-Than;Ko, Seong-Young;Lee, Woo-Jung;Kwon, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2648-2653
    • /
    • 2003
  • This paper describes the development of a 3-DOF laparoscopic assistant robot system with motor-controlled bending and zooming mechanisms using the voice command motion control and auto-tracking control. The system is designed with two major criteria: safety and adaptability. To satisfy the safety criteria we designed the robot with optimized range of motion. For adaptability, the robot is designed with compact size to minimize interference with the staffs in the operating room. The required external motions were replaced by the bending mechanism within the abdomen using flexible laparoscope. The zooming of the robot is achieved through in and out motion at the port where the laparoscope is inserted. The robot is attachable to the bedside using a conventional laparoscope holder with multiple DOF joints and is compact enough for hand-carry. The voice-controlled command input and auto-tracking control is expected to enhance the overall performance of the system while reducing the control load imposed on the surgeon during a laparoscopic surgery. The proposed system is expected to have sufficient safety features and an easy-to-use interface to enhance the overall performance of current laparoscopy.

  • PDF

고령의 식도암 환자에서 다빈치 S 로봇을 이용한 식도 절제술 ($DaVinci^{TM}$ S robot-assisted esophagectomy in a 83-year-old patient with esophageal cancer)

  • 함석진;박성용;백효채
    • 대한기관식도과학회지
    • /
    • 제14권2호
    • /
    • pp.53-56
    • /
    • 2008
  • The postoperative respiratory complications such as pneumonia and ARDS, are poor prognostic factors after esophagectomy in patients with esophageal cancer. To avoid these complications, there have been attempts to use minimally invasive approach. Recently introduced daVinciTM S surgical system is used in esophagectomy because of its advantages of minimal invasiveness, clear 3-dimensional imaging and precise handling of robotic arms. We report a 83-year-old esophageal cancer patient who underwent daVinciTMS robot-assisted esophagectomy, laparoscopic stomach mobilization followed by cervical esophagogastrostomy.

  • PDF

Emerging Role of Robot-assisted Gastrectomy: Analysis of Consecutive 200 Cases

  • Park, Ji Yeon;Kim, Young-Woo;Ryu, Keun Won;Eom, Bang Wool;Yoon, Hong Man;Reim, Daniel
    • Journal of Gastric Cancer
    • /
    • 제13권4호
    • /
    • pp.255-262
    • /
    • 2013
  • Purpose: Robotic surgery for gastric cancer is a promising alternative to laparoscopic surgery, but the data are limited. We aimed to evaluate whether gaining experience in robotic gastrectomy could improve surgical outcomes in the treatment of gastric cancer. Materials and Methods: Two hundred and seven consecutive cases of patients with clinical stage I gastric cancer who underwent robotic surgery at the National Cancer Center of Korea between February 2009 and February 2012 were retrospectively reviewed. Surgical outcomes were analyzed and compared between the initial 100 and later 100 cases. Results: Seven patients required conversion to open surgery and were excluded from further analysis. The mean operating time for all patients was 248.8 minutes, and mean length of hospitalization was 8.0 days. Twenty patients developed postoperative complications. Thirteen were managed conservatively, while 6 had major complications requiring invasive procedures. One mortality occurred owing to myocardial infarction. Operating time was significantly shorter in the latter 100 cases than in the initial 100 cases (269.9 versus 233.5 minutes, P<0.001). The number of retrieved lymph nodes was significantly greater in the latter cases (35.9 versus 39.9, P=0.032). The hospital stay of patients with complications was significantly longer in the initial cases than in the latter cases (16 versus 7 days, P=0.005). Conclusions: Increased experience with the robotic procedure for gastric cancer was associated with improved outcomes, especially in operating time, lymph node retrieval, and shortened hospital stay of complicated patients. Further development of surgical techniques and technology might enhance the role of robotic surgery for gastric cancer.

Similar Operative Outcomes between the da Vinci Xi® and da Vinci Si® Systems in Robotic Gastrectomy for Gastric Cancer

  • Alhossaini, Rana M.;Altamran, Abdulaziz A.;Choi, Seohee;Roh, Chul-Kyu;Seo, Won Jun;Cho, Minah;Son, Taeil;Kim, Hyung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • 제19권2호
    • /
    • pp.165-172
    • /
    • 2019
  • Purpose: The robotic system for surgery was introduced to gastric cancer surgery in the early 2000s to overcome the shortcomings of laparoscopic surgery. The more recently introduced da Vinci $Xi^{(R)}$ system offers benefits allowing four-quadrant access, greater range of motion, and easier docking through an overhead boom rotation with laser targeting. We aimed to identify whether the $Xi^{(R)}$ system provides actual advantages over the $Si^{(R)}$ system in gastrectomy for gastric cancer by comparing the operative outcomes. Materials and Methods: We retrospectively reviewed all patients who underwent robotic gastrectomy as treatment for gastric cancer from March 2016 to March 2017. Patients' demographic data, perioperative information, and operative and pathological outcomes were collected and analyzed. Results: A total of 109 patients were included in the $Xi^{(R)}$ group and 179 in the $Si^{(R)}$ group. Demographic characteristics were similar in both groups. The mean operative time was 229.9 minutes in the $Xi^{(R)}$ group and 223.7 minutes in the $Si^{(R)}$ group. The mean estimated blood loss was 72.7 mL in the $Xi^{(R)}$ group and 62.1 mL in the $Si^{(R)}$ group. No patient in the $Xi^{(R)}$ group was converted to open or laparoscopy, while 3 patients in the $Si^{(R)}$ group were converted, 2 to open surgery and 1 to laparoscopy, this difference was not statistically significant. Bowel function was resumed 3 days after surgery, while soft diet was initiated 4 days after surgery. Conclusions: We found no difference in surgical outcomes after robotic gastrectomy for gastric cancer between the da Vinci $Xi^{(R)}$ and da Vinci $Si^{(R)}$ procedures.