• 제목/요약/키워드: lap-spliced

검색결과 87건 처리시간 0.022초

하이브리드 섬유를 사용한 고인성 섬유보강 시멘트 복합체내의 철근이음에 관한 실험적 연구 (An Experimental Study on the Splice of Reinforcement Embedded in High Performance Hybrid Fiber Reinforced Cementitious Composites)

  • 전에스더;양일승;한병찬;서수연;윤승조;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.319-322
    • /
    • 2005
  • Experimental results on splice strength of concrete and hybrid fiber reinforced cementitious composite are reported. Two series of tests, with six specimens each, were carried out. The research parameters were: bar diameter(D16, D22), lap splice length(50, 75, 100$\%$). The current experimental results demonstrated clearly that the use of hybrid fibers in cementitious matrixes increases significantly the splice strength of reinforcing bars in tension. Also, the presence of fibers increased the number of cracks formed around the spliced bars, delayed the growth of the splitting cracks, and consequently, improved the ductility of bond failure.

  • PDF

Seismic performances of RC columns reinforced with screw ribbed reinforcements connected by mechanical splice

  • Lee, Se-Jung;Lee, Deuck Hang;Kim, Kang Su;Oh, Jae-Yuel;Park, Min-Kook;Yang, Il-Seung
    • Computers and Concrete
    • /
    • 제12권2호
    • /
    • pp.131-149
    • /
    • 2013
  • Various types of reinforcement splicing methods have been developed and implemented in reinforced concrete construction projects for achieving the continuity of reinforcements. Due to the complicated reinforcement arrangements and the difficulties in securing bar spacing, the traditional lap splicing method, which has been widely used in reinforced concrete constructions, often shows low constructability and difficulties in quality control. Also, lap spliced regions are likely to be over-reinforced, which may not be desirable in seismic design. On the other hand, mechanical splicing methods can offer simple and clear arrangements of reinforcement. In order to utilize the couplers for the ribbed-deformed bars, however, additional screw processing at the ends of reinforcing bars is typically required, which often lead to performance degradations of reinforced concrete members due to the lack of workmanship in screw processing or in adjusting the length of reinforcing bars. On the contrary, the use of screw-ribbed reinforcements can easily solve these issues on the mechanical splicing methods, because it does not require the screw process on the bar. In this study, the mechanical coupler suitable for the screw-ribbed reinforcements has been developed, in which any gap between the reinforcements and sleeve device can be removed by grouting high-flow inorganic mortar. This study presents the uniaxial tension tests on the screw-ribbed reinforcement with the mechanical sleeve devices and the cyclic loading tests on RC columns with the developed coupler. The test results show that the mechanical sleeve connection developed in this study has an excellent splicing performance, and that it is applicable to reinforced concrete columns with a proper confinement by hoop reinforcement.

비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과 (Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice)

  • 하상수;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.119-128
    • /
    • 2008
  • 본 연구는 중진지역에서의 PC(precast conctete) 보-기둥 접합부의 새로운 모멘트-저항 시스템을 제안하는 것이다. 철근 이음형 접합부에서 연결재는 접합부를 관통하고, U형 하프 PC 보의 하부철근과 비접촉 겹칩이음으로 연결되어 있다. 비접촉 겹침이음에 대한 성능을 파악하기 위하여 실험적 연구와 해석적 연구가 수행되었다. 실험의 주요변수는 겹침길이, 연결재의 크기, 그리고 겹침이음된 연결재의 거리 등이다. 또한, 균열양상, 하중-변위 곡선, 내력 비교, 그리고 연결재의 변형 등에 초점을 맞추어 해석적 연구를 수행하여 실험결과와 비교하였다. 해석과 실험 결과 주요변수인 겹침길이, 연결재의 크기, 연결재의 비접촉 수직 거리등에 따라 강도, 연성, 그리고 접합부 거동에 큰 영향을 주는 것으로 나타났다.

Seismic behaviour of RC columns with welded rebars or mechanical splices of reinforcement

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.;Konstantinidis, Dimitrios
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.297-306
    • /
    • 2019
  • The extension of existing RC buildings is a challenging process, which requires efficient connection between existing and new materials to guarantee load transferring between the lap-spliced longitudinal columns' reinforcement. Therefore, the length of the columns' starter bars is a crucial factor, which decisively affects the seismic response of the new columns. In particular, when the length of the starter bars is short, then the length of the lap splices of reinforcement is inadequate to ensure load transfer between steel bars and concrete, with an indisputable detrimental impact on the seismic behaviour of the columns. Moreover, in most of the existing RC buildings the column starter bars are of particularly short length, while they have probably been bent, cut or corroded. In the present study, the effectiveness of both welded rebar and mechanical splices of reinforcement in ensuring load transferring between the starter bars and the longitudinal reinforcement of the new column was experimentally evaluated. Four cantilever column subassemblages were constructed and subjected to earthquake-type loading. Three of the specimens were used to examine different types of shielded metal arc welding (SMAW), while in the fourth subassemblage mechanical splices were tested. The hysteretic response of the columns was evaluated and compared to the behaviour of a fifth specimen with continuous reinforcement, tested by Kalogeropoulos and Tsonos (2019). Test results clearly demonstrated that the examined types of SMAW were equally satisfactory in ensuring the ductile seismic performance of the columns, while the mechanical splices found to be more susceptible to exhibit slipping of the bars.

고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가 (Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC)

  • 이한주;정철헌;신동호;박세진;김인규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.196-205
    • /
    • 2017
  • 프리캐스트 바닥판 공법은 바닥판간 이음부가 존재하며, 이음부의 연결성능에 따라 전체 교량 구조물의 성능이 좌우되므로 이음부의 연결성능 확보가 중요한 요소이다. 본 연구에서는 고강도 강섬유보강콘크리트(High Strength Fiber Reinforced Concrete, HSFRC)가 적용된 비대칭 요철형 이음단면을 갖는 연결형식을 제안하였으며, 이음부의 단면형태, 철근 겹침이음길이 및 겹침이음 형식에 따른 구조실험을 수행하여 제안된 연결형식의 휨 성능을 평가하였다. 실험결과, 이음부 상세에 관계없이 이음철근은 항복변형률 수준의 인장변형을 나타내었으며, 제안된 연결형식은 충분한 휨 저항성능을 확보하는 것으로 나타났다. 이러한 실험결과는, 현행 도로교설계기준의 최소 겹침이음길이에 대한 규정은 이음부 채움재로 HSFRC를 적용한 프리캐스트 바닥판 이음부에서는 보수적인 규정임을 알 수 있다. 따라서 이음부 채움재로 HSFRC를 사용함에 의해 철근 겹침이음 상세의 단순화 및 이음부 폭의 감소가 가능하며, 제안된 연결형식은 프리캐스트 바닥판 이음부에 효과적으로 적용 가능할 것으로 판단된다.

형상비 2.5의 RC 교각의 내진 곡률연성도 (Seismic Curvature Ductility of RC Bridge Piers with 2.5 Aspect Ratio)

  • 정영수;박창규;이은희
    • 한국지진공학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-12
    • /
    • 2004
  • 1989년 로마프리타지진 및 1995년 효고현 남부지진등 많은 교각에서 휨-전단 파괴에 의한 피해가 발생하였다. 그럼에도 불구하고 지금까지의 교각의 내진성능에 관한 연구는 대부분 휨파괴에 대한 연구가 지배적이었다. RC 교각의 내진성능은 교각의 소성힌지구간의 성능에 좌우되고 있으며, 소성힌지의 연성은 곡률에 의해 평가하는 것이 바람직하다. 실험연구는 지진하중의 손상을 입은 RC교각의 휨전단거동에 관한 소성힌지구간 내의 곡률변화를 평가하였다. 실험에 사용된 7기의 실험체는 형상비 2.5에 횡방향 구속력, 주철근의 겹침이음 그리고 섬유보강을 변수로 가지고 있다. 이 실험체는 유사동적실험 수행을 통해 손상을 주었으며, 유사동적실험 후에는 일정한 축력,$P=0.1f_{ck}A_g$을 유지하면서 변위제어방식으로 유사정적실험을 실시하여 잔류내진성능을 평가하였다. 실험 결과 기초에서 15cm 구간에 가장 큰 곡률이 발생하였으며 파괴도 이 단면에 집중되었다. 또한, 연성도 분석결과 주철근이 겹침이음 된 RC 교각이 낮은 곡률연성도를 보였으며, 이를 섬유보강한 실험체의 휨강성과 곡률연성도는 현저히 개선되었다. 그리고, 교각의 곡률변화를 분석하여 횡구속력을 고려한 등가소성힌지길이 산정식을 제안하였으며, 이 제안된 식을 적용하여 변위연성도와 곡률연성도 관계를 분석하였다.

진동대 실험에 의한 RC교각의 주철근 변형률 분석 (Strain Analysis of Longitudinal Reinforcing Steels of RC Bridge Piers Under Shaking Test)

  • 홍현기;양동욱;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.93-96
    • /
    • 2008
  • 근단층지반운동(NFGM)은 장주기 성분의 펄스 형태를 갖는 지반운동이다. 이들 근단층지반운동은 1994년 미국 Northridge 지진, 1995년 일본 Kobe 지진, 1999년 터키 Izmit 지진 등과 같은 강진 지역에서 관측되었으며 이들 지진의 진앙이 도시 주변에 위치하여 큰 피해를 초래한 바 있다. 강진 지역에서는 원역단층지반운동(FFGM)에 대해 폭넓은 연구가 수행되었으나 비내진 또는 중저진 지역에서는 NFGM에 대한 연구가 미흡한 실정이다. 이 연구는 주철근 겹침이음이 없는 RC 교각을 근단층지반운동에 대해서 해석 연구하는 것이다. 2기의 RC교각은 진동대 실험으로 근단층지반운동을 가력하였다. 추가로 2기의 RC교각은 준정적 실험으로 나머지 2개의 RC교각은 유사동적 실험으로 수행하였다. 이 논문은 횡방향 철근비가 증가 할수록 더 큰 PGA에서 철근이 파괴된다는 것을 보여준다.

  • PDF