• Title/Summary/Keyword: lamp installation

Search Result 353, Processing Time 0.028 seconds

Ozone Processing Storage Characteristic of Main Herb Medicines (주요 한약재의 오존처리저장 특성)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • Recently, many storing methods were applied to keep quality of herb medicines during storage. Among of thent we tried to research a method to store after dissolving remaining harmful bacillus and agricultural chemicals of herb medicines. We confirmed that ozone processing is superior at the sterilization of bacteria and virus from the leading research about ozone generator, and then we made research method to apply with the sterilization and storing processing of herb medicines using ozone (OPS). In this study we chose herb medicines of 4 kinds which have been sold much in the market, evaluated the characteristics. Namely, we used ozone lamp in a storage system and investigated the sterilization characteristic of herb medicines. We executed a quantitative analysis of the general ingredient and the physiological activity ingredient to investigate whether the original ingredient and the quality of herb medicines is preserved, after doing an ozone md storing processing for a long term.

A Study on Improvement of Lighting Environment of Night-Scape in Anyang-si (안양시 야간경관 조명환경 개선방향에 관한 연구)

  • Park, Joo-Young;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.27-35
    • /
    • 2009
  • This study aimed to find problems of nightscape of Anyang-si through examination of behavioral pattern at night and measurement of illumination and luminance in accordance with regional classification following 6 regional classifications on the basis of ur1xm characteristic of Anyang-si. Basic concept of nightscape creation was application of improvement plan with analysis of regional problems and creation of artistic value to enhance image of Anyang-si as a city of art. To obtain balance and unity of night illumination, concept of light zoning was applied to smooth-transform method by regions. Especially, right to view harmonized with surrounding scenery was secured through creating gradual skyline compatible with neighbor buildings using division of each buildings according to their heights. In addition, way to improvement of night lighting environment was proposed as to illumination, height, type of lamp and arrangement of street lights and furniture in accordance with regional characteristics.

Supplemental Lighting by HPS and PLS Lamps Affects Growth and Yield of Cucumber during Low Radiation Period (약광기 HPS와 PLS lamp를 이용한 오이의 보광재배효과)

  • Kwon, Joon-Kook;Yu, In-Ho;Park, Kyoung-Sub;Lee, Jae-Han;Kim, Jin-Hyun;Lee, Jung-Sup;Lee, Dong-Soo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.400-406
    • /
    • 2018
  • In this experiment the effect of supplemental lighting on the growth and yield of cucumber (Cucumis sativus L. 'Fresh') plants during low radiation period of winter season were investigated in glasshouses using common high-pressure sodium (HPS) lamps and newly developed plasma lighting system (PLS) lamps. Plants grown without supplemental lighting were considered as a control. Supplemental lighting was provided from November 20th, 2015 to March 15th, 2016 to ensure 14-hour photoperiod (natural+supplemental light), also lamps were operated automatically when the outside sun radiation levels were less than $100W{\cdot}m^{-2}$. Spectral analysis showed that HPS lamp had a discrete spectrum, lacked of the radiation in the 400-550 nm wave band (blue-green light), but had a high output in the orange-red region (550-650 nm). A higher red light output resulted in an increased red to far-red (R/FR) ratio in HPS lamp. PLS had a continuous spectrum and had a peak radiation in green region (490-550 nm). HPS has 12.6% lower output in photosynthetically active radiation (PAR) but 12.6% higher output in near infra-red (NIR) spectral regions compared to PLS. Both HPS and PLS lamps emitted very low levels of ultra-violet radiation (300-400 nm). Supplemental lighting both from HPS and PLS lamps increased plant height, leaf number, internode number and dry weight of cucumber plants compared to control. Photosynthetic activity of cucumber plants grown under two supplemental lighting systems was comparable. Number of fruits per cucumber plant (fruit weight per plant) in control, PLS, and HPS plots were 21.2 (2.9 kg), 38.7 (5.5 kg), and 40.4 (5.6 kg), respectively, thereby increasing yield by 1.8-1.9 times in comparison with control. An analysis of the economic feasibility of supplemental lighting in cucumber cultivation showed that considering lamp installation and electricity costs the income from supplemental lighting increased by 37% and 62% for PLS and HPS lamps, respectively.

Estimation of GHG emission and potential reduction on the campus by LEAP Model (LEAP 모델을 이용한 대학의 온실가스 배출량 및 감축잠재량 분석)

  • Woo, Jeong-Ho;Choi, Kyoung-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.409-415
    • /
    • 2012
  • Post-kyoto regime has been discussing with the GHG reduction commitment. GHG energy target management system also has been applied for the domestic measures in the country. Universities are major emission sources for GHG. It is very important for campus to built the GHG inventory system and estimate the potential GHG emission reduction. In general, GHG inventory on the campus was taken by the IPCC guidance with the classification of scope 1, 2, and 3. Electricity was the highest portion of GHG emission on the campus as 5,053.90 $tonsCO_2eq/yr$ in 2009. Manufacturing sector was the second high emission and meant GHG in laboratory. Potential GHG reduction was planned by several assumptions such as installation of occupancy sensor, exchanging LED lamp and photovoltaic power generation. These reduction scenarios was simulated by LEAP model. In 2020, outlook of GHG emission was estimated by 17,435.98 tons of $CO_2$ without any plans of reduction. If the reduction scenarios was applied in 2020, GHG emission would be 16,507.60 tons of $CO_2$ as 5.3% potential reduction.

A study on the design and performance of a stand-alone photovoltaic lighting system (독립형 태양광 조명 시스템의 설계 및 성능 평가 연구)

  • Kwon, Oh-Sang;Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

Practical Design of an Artificial Light-Used Plant Factory for Common Ice Plant (Mesembryanthemum crystallinum L.) (인공광 이용형 Common Ice Plant 식물공장의 실용적 설계)

  • Cha, Mi-Kyung;Kim, Ju-Sung;Shin, Jong Hwa;Son, Jung Eek;Cho, Young Yeol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.371-375
    • /
    • 2014
  • This study was carried out to get the basic data to practically design an artificial light-used plant factory system for common ice plant (Mesembryanthemum crystallinum L.) cultivation. The adequate range of light intensity was $120-200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the carbon fixed rates was $0.84nmolCO_2{\cdot}cm^{-2}{\cdot}s^{-1}$. When the planting density, light intensity, and yield were $0.0225m^2$ ($15{\times}15cm$), $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and 1,000 plants per day, the total number of the plants, cultivated area, and total light intensities were estimated as 25,000 plants, $563m^2$, and $140,625{\mu}mol{\cdot}s^{-1}$, respectively. About 153.2kW with 2,785 fluorescent lights (FL) needed for the electric power and the electricity charges was 2.46 million won for one month. At a harvest rate of 1,000 plants per day in closed-type plant factory, the light installation cost, total installation cost, and total production cost were 27.85, 83.56, and 100.27 million won, respectively. The production cost per plant including labor cost was calculated as 370 won, providing that the cultivation period was 25 days and marketable ratio was 80%. Considering the annual total expenses, incomes, and depreciation cost, the sales cost per plant could be estimated around 970 won or higher.

Resolution Method of Hazard Factor for Life Safety in Rental Housing Complex (임대주택단지의 생활안전 위해요인 해소방안)

  • Sohn, Jeong-Rak;Cho, Gun-Hee;Kim, Jin-Won;Song, Sang-Hoon
    • Land and Housing Review
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • The government has been constructing and supplying public rental housing to ordinary people in order to stabilize housing since 1989. However, the public rental houses initially supplied to ordinary people are at high risk for safety accidents due to the deterioration of the facilities. Therefore, this study is aimed to propose a solution to solve the life safety hazards of the old rental housing complex as a follow-up study of Analysis of Accident Patterns and Hazard Factor for Life Safety in Rental Housing Complex. Types of life safety accidents that occur in public rental housing complexes are sliding, falling, crash, falling objects, breakage, fire accidents, traffic accidents and criminal accidents. The types of safety accidents that occur in rental housing complexes analyzed in this study are sliding, crashes, falling objects, and fire accidents. Although the incidence of safety accidents such as falling, breakage, traffic accidents and crime accidents in public rental housing complexes is low, these types are likely to cause safety accidents. The method of this study utilized interviews and seminar results, and it suggested ways to solve the life safety hazards in rental housing complexes. Interviews were conducted with residents and managers of rental housing complexes. Seminars were conducted twice with experts in construction, maintenance, asset management, housing welfare and safety. Through interviews and seminars, this study categorizes the life safety hazards that occur in rental housing complexes by types of accidents and suggests ways to resolve them as follows. (1) sliding ; use of flooring materials with high friction coefficient, installation of safety devices such as safety handles, implementation of maintenance, safety inspections and safety education, etc. (2) falling ; supplementation of safety facilities, Improvement of the design method of the falling parts, Safety education, etc. (3) crash ; increase the effective width of the elevator door, increase the effective width of the lamp, improve the lamp type (U type ${\rightarrow}$ I type), etc. (4) falling objects and breakage ; design of furniture considering the usability of residents, replacement of old facilities, enhancement of safety consciousness of residents, safety education, etc. (5) fire accidents ; installation of fire safety equipment, improvement by emergency evacuation, safety inspection and safety education, etc. (6) traffic accidents ; securing parking spaces, installing safety facilities, conducting safety education, etc. (7) criminal accidents; improvement of CCTV pixels, installation of street lights, removal of blind spots in the complex, securing of security, etc. The roles of suppliers, administrators and users of public rental housing proposed in this study are summarized as follows. Suppliers of rental housing should take into consideration the risk factors that may arise not only in the design and construction but also in the maintenance phase and should consider the possibility of easily repairing old facilities considering the life cycle of rental housing. Next, Administrators of rental housing should consider the safety of the users of the rental housing, conduct safety checks from time to time, and immediately remove any hazardous elements within the apartment complex. Finally, the users of the rental housing needs to form a sense of ownership of all the facilities in the rental housing complex, and efforts should be made not to cause safety accidents caused by the user's carelessness. The results of this study can provide the necessary information to enable residents of rental housing complexes to live a safe and comfortable residential life. It is also expected that this information will be used to reduce the incidence of safety accidents in rental housing complexes.

Sensibility Evaluation on the Correlated Color Temperature in White LED Lighting (백색 LED 조명의 색온도에 관한 감성평가)

  • Jee, Soon-Duk;Lee, Sang-Hyuk;Choi, Kyoung-Jae;Park, Joung-Kyu;Kim, Chang-Hae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2008
  • The aim of this study is to investigate the sensitivity evaluation of human beings in reacting to the correlated color temperature of the optical properties of white LED lighting. For the sake of this study, white light-emitting diode modules have been fabricated their correlated color temperature have been measured, test cabinets for the sensitivity evaluation have been constructed with the white LED modules, and their sensitivity reactions on the test cabinets have been evaluated and analyzed. The sensitivity reaction has been evaluated by the semantic differential method with 15 selected questions, and the reliability and the content validity of their lighting have been analyzed to 3 factors which foe the activity as the first factor, the stability as the second one, the potency as the third one, respectively. For the data analysis on the sensitivity reaction, the dependent variable is the score of the sensitivity evaluation and the independent one is the correlated color temperature of the test module. The results of this study is as follows: In the case of the sensitive evaluation on the activity and the potency in the white LED lighting compared with the fluorescent lamp, the subjects have made higher mark on $MA_3$ with 8,300[K], and in the factor of the stability, they have made higher mark on $MA_1$ with 3,800[K].

A Study on Characteristic Analysis of Single-Stage High Frequency Resonant Inverter Link Type DC-DC Converter (단일 전력단 고주파 공진 인버터 링크형 DC-DC 컨버터의 특성해석에 관한 연구)

  • Won, Jae-Sun;Park, Jae-Wook;Seo, Cheol-Sik;Cho, Gyu-Pan;Jung, Do-Young;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.16-23
    • /
    • 2006
  • This paper presents a novel single-stage high frequency resonant inverter link type DC-DC converter using zero voltage switching with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant converter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant converter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

Design of Emergency Light - Focusing on Public Facilities (피난유도등 디자인 연구 -다중이용시설을 중심으로)

  • Yoo, Ga-Hee;Yang, Sung-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.301-308
    • /
    • 2020
  • Based on the analysis of fire escape situations in public facility, this study was intended to propose a design of emergency light suitable for fire in public facility. A video analysis was conducted to understand the evacuation situation of public facility because the fire could not be randomized due to the disaster. Through video analysis, we were able to identify inconvenience and necessary needs in avoiding fire in public facility and reflected them in the design of emergency light, etc. As a result of the design of emergency light, the wall type induction lamp had different LED layout structures to minimize the thickness of the product. Ceiling induction lamps have been supplemented for additional installation in corridors of complex structures. The results of this study are designed based on the criteria used in the manufacture of actual emergency light and we intend to explore ways to be practical through further experiment measurements and complementary steps through expert advice.