• Title/Summary/Keyword: l-methamphetamine

Search Result 11, Processing Time 0.024 seconds

Gas Chromatographic Analysis of Optical Isomers of Methamphetamine and Amphetamine After Administration of I-Deprenyl(Selegiline) to Rats (I-디프레닐 투여 후 흰쥐 뇨중 메스암페타민 및 암페타민의 거울상이성질체의 가스크로마토그래피에 의한 분석)

  • Kim, Eun-Mi;Kim, Sun-Cheun;Chung, Hee-Sun;Yoo, Young-Chan
    • YAKHAK HOEJI
    • /
    • v.41 no.6
    • /
    • pp.698-703
    • /
    • 1997
  • Recently, l-deprenyl (selegiline), a relative new antiparkinson`s drug, has been marketed in Korea. As its metabolites, l-methamphetamine and l-amphetamine, are the enantiomers of illicit drugs,d-methamphetamine and d-amphetamine, a method for analysis of enantiomers of methamphetamine and amphetamine in rat urine was investigated. The optical isomers of methamphetamine and amphetamine were analyzed with the chiral derivatizing reagent (S)-(-)-N-(trifluoroacetyl)-prolyl chloride (l-TFP), which was used to form the diastereomers of methamphetamine and amphetamine. And all diastereomers (l-TFP -l-AM, lTFP-d-AM, l-TFP-l-MA & l-TFP-d-MA) were well resolved by capillary gas chromatography. After administration of 10mg/kg l-deprenyl to rat, l-methamphetamine and l-amphetamine were detected without autoracemization to the d form in all urine samples collected during 24hrs, and the ratios of l-amphetamine/l-methamphetamine were 1.1~3.3. l-Amphetamine was detected in only 3 out of 8 urine samples collected during 24~48hrs where as no l-methamphetamine was detected in all cases.

  • PDF

Enantiomeric Separation of Methamphetamine Abused in Korea (우리나라에서 남용되는 메스암페타민의 거울상 이성질체분리)

  • Yoo, Young-Chan;Chung, Hee-Sun;Choi, Hwa-Kyung;Kim, Eun-Mi;Kim, Mi-Kyung;Kim, Sun-Choon
    • YAKHAK HOEJI
    • /
    • v.41 no.3
    • /
    • pp.277-282
    • /
    • 1997
  • Methamphetamine, which is the most commonly abused drug in Korea, exists in terms of d-, l- isomers and a racemate(dl). d-Methamphetamine is a potent central nervous system stimulant, whereas l-Methamphetamine is sold freely as a nasal decongestant. In addition, methamphetamine appears in different ratios of optical isomers by the clandestine synthesis applied. In this study, enetiomeric separation of methamphetamines was estabilished to distinguish the chirality of methamphetamines trafficked and abused in Korea. A gas chromatograph/mass spectrometer(GC/MS) system equipped with an achiral capillary column is used to isolate the isomers of methamphetamine after (S)-N-(trifluoroacetyl)-l-prolyl(TFP) deravatization.After analyzing 10 illicit methamphetamine powders and 10 positive urine samples, following findings were found: d-Methamphetamine was well resolved from l-Methamphetamine by chromatographic separation of TFP derivatibes on DB-5 with retention time of 11.80 and 11.35 min respectively. The detection of d-Methamphetamine in all 10 powders and 10 urine samples proves that all methamphetamines abused in Korea are illegally manyfactured and administred.

  • PDF

Abuse Liability Assessment of l-Deprenyl by Testing Methamphetamine-like Discriminative Effects (메탐페타민 유사 분별능 시험을 통한 l-디프레닐의 약물남용가능성 평가)

  • Lee, Sun-Hee;Kim, Pu-Young
    • YAKHAK HOEJI
    • /
    • v.42 no.1
    • /
    • pp.101-107
    • /
    • 1998
  • The antiparkinsonian agent l-deprenyl, a selective monoamine oxidase (MAO)-B inhibitor, is metabolized in part to l-methamphetamine and l-amphetamine. l< /I>-Deprenyl was evaluated for amphetamine and methamphetamine-like discriminative stimulus effects in rats and its mechanism of action was investigated. Rats were trained under a 5-response, fixed ratio schedule of stimulus-shock termination or a 10-response. Fixed-ratio schedule of food-presentation which discriminate between d-amphetamine (1mg/kg, i.p.) and saline or d-methamphetamine (1mg/kg, i.p.) and saline in a two-lever, operant conditioning procedure. Full generalization was obtained to d-amphetamine (1~3mg/kg). d-methamphetamine (1~3mg/kg) and l-deprenyl (17~30mg/kg) under both the food presentation and stimulus shock termination schedule. l-Deprenyl has dose-dependent amphetamine-and methamphetamine-like discriminative stimulus properties in rats only at doses of 17 and 30mg/kg. Reversible MAO-B inhibitor, RO 16-6491 didn`t show any amphetamine-like discriminative properties. Aromatic amino acid decarboxylase inhibitor, NSD 1015 decreased % responding of l-deprenyl in the methamphetamine-trained rats under the stimulus-shock termination schedule. SKF-525A produced partial inhibition of methamphetamine-like discriminative effects of l-deprenyl under the food presentation schedule. These results suggest that l-deprenyl has no abuse liability at the therapeutic range but there needs some caution at high doses and furthermore, drug discrimination studies under the food presentation and shock termination schedule are useful for the assessment of abuse liability of psychostimulants.

  • PDF

Survival after Cardiac Arrest due to Acute Methamphetamine Poisoning: A Case Report (메스암페타민(필로폰) 급성 중독으로 유발된 심정지 후 생존한 1례)

  • Mun, You Ho;Kim, Jung Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.176-180
    • /
    • 2018
  • Drug abuse and its related problems are increasing continuously in Korea. One of the most frequently abused drugs is methamphetamine, but there are few medical report in Korea. This is the first report of the identification of methamphetamine in the blood of a patient who had a return of spontaneous circulation after cardiac arrest and survived discharge. A 33-year-old male arrived at the emergency department presenting with chest pain and dyspnea. He had ingested methamphetamine and alcohol approximately 7 hours before arrival. One hour after arrival, he had seizure followed by cardiac arrest. Spontaneous circulation was recovered after 4 minutes of CPR. An analysis of the National Forensic Service identified plasma methamphetamine with an estimated average concentration of plasma methamphetamine at the time of arrival of 0.6 mg/L, a lethal dose. He had rhabdomyolysis and acute kidney injury but survived after continuous renal replacement therapy. Since then, he has suffered chronic kidney disease, and he is being followed up at the out-patient department. In Korea, although drug abuse is still uncommon, it is on the increase. Therefore, emergency physicians should be aware of the clinical characteristics of methamphetamine poisoning.

Screening method for amines by derivatization reaction on TLC (TLC 상 유도체화 반응을 이용한 아민 계 화합물의 Screening 방법)

  • Choi, Sung-Woon;Lee, Hye-In;Sung, Nack-Do
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.228-234
    • /
    • 2013
  • Methamphetamine is an amine-containing illegal drug and is distributed unlawfully in South Korea. Finding a rapid, convenient and semi-quantitative determination method for methamphetamine is a very important issue in the area of forensic drug testing. As an effort to develop new screening method, the reactions between three organic compounds which are structurally similar to methamphetamine and N-(9-fluorenylmethoxycarbonyloxy) succinimide (FMOC-NHS) were performed on silica gel ($SiO_2$) TLC plates. Three reference compounds were synthesized and used for the identification, comparison and study of the limit of detection (LOD) of the products obtained from a direct reaction on a TLC plate. As a result, FMOC-NHS as a derivatization reagent generated compounds containing highly UV-active functional groups on the TLC plate after reacting with primary- and secondary amines. In the experiment 2D the LOD of amines was in the range of 0.045 and 0.01 mg/mL ($2{\mu}L/spot$), and in 1D the LOD was in the range of 0.002 and 0.007 mg/mL ($2{\mu}L/spot$). The LODs of the compounds tested were dependent on the concentration of the derivatizing reagent.

Determination of methamphetamine and amphetamine enantiomers in human urine by chiral stationary phase liquid chromatography-tandem mass spectrometry

  • Sim, Yeong Eun;Ko, Beom Jun;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.163-172
    • /
    • 2019
  • Methamphetamine (MA) is currently the most abused illicit drug in Korea and its major metabolite is amphetamine (AP). As MA exist as two enantiomers with the different pharmacological properties, it is necessary to determine their respective amounts in a sample. Thus a chiral stationary phase liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of d-MA, l-MA, d-AP, and l-AP in human urine. Urine sample ($200{\mu}L$) was diluted with pure water and purified using solid-phase extraction (SPE) cartridge. A $5-{\mu}L$ aliquot of SPE treated sample solution was injected into LC-MS/MS system. Chiral separation was carried out on the Astec Chirobiotic V2 column with an isocratic elution for each enantiomer. Identification and quantification of enantiomeric MA and AP was performed using multiple reaction monitoring (MRM) detection mode. Linear regression with a $1/x^2$ as the weighting factor was applied to generate a calibration curve. The linear ranges were 25-1000 ng/mL for all compounds. The intra- and inter-day precisions were within 3.6 %, while the intra- and inter-day accuracies ranged from -5.4 % to 11.8 %. The limits of detection were 2.5 ng/mL (d-MA), 3.5 ng/mL (l-MA), 7.5 ng/mL (d-AP), and 7.5 ng/mL (l-AP). Method validation parameters such as selectivity, matrix effect, and stability were evaluated and met acceptance criteria. The applicability of the method was tested by the analysis of genuine forensic urine samples from drug abusers. d-MA is the most common compound found in urine and mainly used by abusers.

Bioluminescence Single-Site Immunometric Assay for Methamphetamine Using the Photoprotein Aequorin as a Label

  • Kim, Hyun-Sook;Paeng, Insook-Rhee
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.407-412
    • /
    • 2006
  • Bioluminescence single-site immunometric assay for methamphetamine (MA) using the native aequorin, a photoprotein, as a signal generator was developed for the first time. MA is a potent sympathomimetic amine with stimulant effects on the central nervous system. MA abuse induces hallucinations and, thus, may cause a serious social problem. The single-site immunometric MA assay was optimized and its dose-response behavior was examined. The dose-response curve shows that the detection limit is 1.1 ${\times}$ $10^{-10}$ M and a dynamic range is four orders of magnitude with 15 $\mu$g/mL BSA-MA conjugate and 1.0 ${\times}$ $10^{-8}$ M anti-MA antibody-biotin conjugate. In order to evaluate this assay, the structurally similar compounds, amphetamine, ephedrine, norephedrine, benzphetamine and N-4-(aminobutyl)methamphetamine were examined for their crossreactivity. None of these five compounds showed any cross-reactivity. Additionally, an artificial urine solution spiked with MA was analyzed by the MA assay, and the result of the analysis demonstrated the usefulness of the present assay for the determination of MA in urine.

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.

Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS (고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Although liquid-liquid extraction (LLE) method has been used routinely for the analysis of amphetamine-like drugs (amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA), a solid-phase extraction (SPE) method, which can be automated, was applied for the simultaneous determination by GC/MS in human urine. Urine samples (3 mL) and 0.1 M phosphate buffer (1 mL, pH 7.0) were extracted by an automated SPE system. The eluent was evaporated, derivatized with trifluoroacetic anhydride (TFAA), and analyzed by GC/MS. The calibration curves was linear with correlation coefficient ($r^2$) above 0.994 in the ranges of 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL for AP, MDA, and 50.0~2000.0 ng/mL for MA, MDMA, and MDEA. The limits of detection ranged from 4.0 to 10.0 ng/mL, and the limits of quantitation ranged from 12.0 to 34.0 ng/mL. The relative recoveries were 93.5~107.7 %. The precisions and accuracies were 1.9~14.8 % and -8.7~14.8 %, respectively. The present method was successfully applied to identify the MA or Ecstasy (MDMA) abusers in exact as well as rapid.

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.