• Title/Summary/Keyword: korean image

Search Result 29,667, Processing Time 0.064 seconds

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

MR Images of Bowel Wall Thickening in Patients with Minimal to Moderate Cirrhosis: Comparison with Clinical Findings (경증과 중등도 간경화 환자에서 장관 비후의 MR 영상: 임상소견과의 비교)

  • Mitchell Donald G.;Hann Hie-Won L.;Parker Laurence;Kim, Mi-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.81-88
    • /
    • 2006
  • Purpose : To evaluate the MR imaging findings of bowel wall thickening in patients with minimal to moderate cirrhosis, and analyze their clinical significances comparing with laboratory findings. Materials and Methods : We assessed retrospectively the MRI findings of 123 patients with minimal to moderate cirrhosis, and compared these with the clinical laboratory findings. We evaluated the involved sites and MR image findings of thickened bowel wall, as well as the presence of collateral vessels, ascites, and splenic size. These were compared with serum albumin and bilirubin levels, and prothrombin time. Results : Gastrointestinal wall thickening was detected at 37 sites in 25 patients (20%), and more frequently detected in moderate cirrhosis (29%) than in minimal cirrhosis (17%). Jejunum and ascending colon were the most common sites of bowel wall thickening; each was involved at 22 and 9 sites, respectively. Ascending colonic wall thickening was more commonly detected in moderate cirrhosis than in minimal cirrhosis. The thickened bowel wall showed symmetric contour, high signal intensity on T2-weighted images, mixed iso- and low signal intensity on T1-weighted images, and homogeneous or target-like enhancement. Serum albumin level was significantly lower in patients with bowel wall thickening ($3.3{\pm}0.9$ g/dl vs. $3.9{\pm}0.7$ g/dl; p=0.0024). Serum bilirubin level was significantly higher in patients with bowel wall thickening ($1.7{\pm}1.0$ mg/dl vs. $1.4{\pm}1.2$ mg/dl; p=0.0160). Bowel wall thickening did not significantly correlate with the presence of collateral vessels, ascites, splenic size, and prolongation of prothrombin time. Conclusion : In minimal to moderate cirrhosis, the MR imaging evaluation of bowel wall thickening was useful for estimating the severity of cirrhosis and laboratory findings.

  • PDF

Changes in Total Cerebral Blood Flow with Aging, Parenchymal Volume Changes, and Vascular Abnormalities: a Two-dimensional Phase-Contrast MRI Study (나이와 뇌실질부피 변화 및 혈관이상에 따른 총뇌혈류량 변화: 이차원 위상대조 자기공명영상을 이용한 연구)

  • Liu Haiying;Shin Tae-Beom;Youn Seong-Kuk;Oh Jong-Yong;Lee Young-Il;Choi Sun-Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • Purpose : To evaluate changes in total cerebral blood flow (tCBF) with aging, parenchymal volume changes and vascular abnormalities, using 2 dimensional (D) phase-contrast magnetic resonance imaging (PC MRI). Materials and Methods : Routine brain MRI including T2 weighted image, time-of-flight (TOF) MR Angiography (MRA) and 2D PC MRI were performed in 73 individuals, including 12 volunteers. Normal subjects (12 volunteers, and 21 individuals with normal MRI and normal MRA) were classified into groups according to age (18-29, 30-49 and 50-66 years). For the group with abnormalities in brain MRIs, cerebral parenchymal volume changes were scored according to the T2 weighted images, and atherosclerotic changes were scored according to the MRA findings. Abnormal groups were classified into 4 groups: (i) mild reduction in volume, (ii) marked reduction in volume by parenchymal volume and atherosclerotic changes, and (iii) increased volume and (iv) Moya-moya disease. Volumetric flow was measured at the internal carotid artery (ICA) and vertebral artery bilaterally using the velocity-flow diagrams from PC MRI, and combined 4 vessel flows and tCBF were compared among all the groups. Results : The age-specific distribution of tCBFs in normal subjects were as follows: $12.0{\pm}2.1ml/sec$ in 18-29 years group, $11.8{\pm}1.9ml/sec$ in 30-49 years group, $10.9{\pm}2.2ml/sec$ in 50-66 years group. The distribution of tCBFs in the different subsets of the abnormal population were as follows: $9.5{\pm}2.5ml/sec$ in the group with mild reduction in volume, $7.6{\pm}2.0ml/sec$ in the group with marked reduction in volume, and $7.3{\pm}1.2ml/sec$ and $7.0{\pm}1.1ml/sec$ in the increased parenchymal volume and Moya-moya disease groups respectively. Conclusion : Total cerebral blood flow decreases with increasing age with a concomitant reduction in parenchymal volumes and increasing atherosclerotic changes. It is also reduced in the presence of increased parenchymal volume and Moya-moya disease.2D PC MRI can be used as a tool to evaluate tCBF with aging and in the presence of various conditions that can affect parenchymal volume and cerebral vasculature.

  • PDF

The Usefulness of Scintigraphy for the Detection of Gastroesophageal Reflux and Pulmonary Aspiration (위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성)

  • Kang, Sung-Kil;Hyun, In-Young;Lim, Dae-Hyun;Kim, Jeong-Hee;Son, Byong-Kwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.12-20
    • /
    • 2008
  • Purpose: Chronic pulmonary disease may be caused by aspiration of gastric contents secondary to gastroesophageal reflux. At present, there is no gold standard for documenting pulmonary aspiration. The purpose of this study was to investigate the usefulness of radionuclide scintigraphy in the detection of gastroesophageal reflux and pulmonary aspiration. Methods: Thirty-five patients with suspected aspiration pneumonia, and five normal control subjects, were included in the study. All subjects underwent gastroesophageal reflux scintigraphy after the ingestion of a $^{99m}Tc$-tin colloid mixture. Dynamic images to detect gastroesophageal reflux were obtained for 1 hour. Additional static images of the chest, to detect lung aspiration, were obtained at 6 and 24 hours after oral ingestion of the tin colloid. In addition to visual analysis, pulmonary aspiration was quantitated by counting the number of pixels labeled with radioactive isotope in the region of interest (ROI) of both lung fields. Aspiration index (AI) was obtained by subtracting the pixel counts of the background from the pixel counts of the ROI. Results: Among 35 patients with suspected aspiration pneumonia, 23 proved to have gastroesophageal reflux by scintigraphy. One patient showed definite pulmonary accumulation of activity by visual analysis of the 6-hour image. Thirty of 35 (85.7%) patients showed higher AI beyond the upper limit of AI in the healthy controls. When we compared the reflux group with the non-reflux group, there was a significantly higher AI at 6 hours in the reflux group (p<0.05). Conclusion: The results suggest that radionuclide scintigraphy is useful in detecting small pulmonary aspiration in patients with suspected aspiration pneumonia secondary to reflux.

  • PDF

The Relationship between Thymic Size and Vesicoureteral Reflux in Infants with Febrile Urinary Tract Infection (발열성 요로감염 영아에서 방광요관역류와 연관된 흉선의 크기)

  • Jung, Seong-Kwan;Park, Kyu-Hee;Yim, Hyung-Eun;Yoo, Kee-Hwan;Hong, Young-Sook;Lee, Joo-Won
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • Purpose : Thymus is a lymphoproliferative organ that changes size in various physiological states in addition to some pathological conditions. Thymus is susceptible to involution, and shows a dramatic response to severe stress. Thymic measurements may be helpful in various diseases. UTI (urinary tract infection) is most common bacterial infection in infants and VUR (vesicoureteral reflux) is a common abnormality associated with UTI. In our study, the size of thymus was compared on the premise that a greater stress is exerted on the body when UTI is accompanied by VUR, than when occurs on its own. Methods : Thymic size was measured on standard chest anteroposterior radiographs and expressed as the ratio between the transverse diameter of the cardiothymic image at the level of the carina and that of the thorax (CT/T). The medical records of 99 febrile urinary tract infection infants without other genitourinary anomalies except VUR were reviewed retrospectively. Results : Among 99 patients with febrile UTIs, 25 were febrile UTI without VUR and 74 with VUR. For the UTI with VUR group, there was a significant decrease in the thymic size compared to the those without VUR group ($0.382{\pm}0.048$ vs $0.439{\pm}0.079$, P<0.05). However, there were no differences in the duration of fever and WBC, CRP between the UTI with VUR and UTI without VUR. In addition, there were no differences in the cardiothymic/thoracic ratios between renal defects and renal scars in febrile UTI patients. Conclusion : The results of this study show that the shirinkage of thymus was more frequently found in the UTI patients with VUR. Therefore, awareness of the risks associated with thymic size is important for the appropriate work up and management of UTI patients.

Is Skeletonized Internal Mammary Artery Harvesting better than Pedicled Harvesting in Respect of the Sternal Blood Flow\ulcorner: An Estimation Using Bone Scan (내유동맥의 골격화 채취는 흉골로의 혈류 감소 측면에서 과연 유리한가 \ulcorner: 골주사를 이용한 평가)

  • 손국희;김영삼;김정택;윤용한;김광호;최원식;백완기
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.511-516
    • /
    • 2004
  • Background: One of the theoretical advantages of skeletonized internal mammary artery harvesting in coronary artery bypass surgery is to minimize the interruption of the sternal blood flow inevitably accompanied by internal mammary harvesting. A study using bone scan is designed to determine the effects of internal mammary artery harvesting technique on the sternal blood flow. Material and Method: From April 2002 to March 2003, 27 patients out of 48 patients who underwent the isolated coronary bypass surgery were enrolled into the study. The enrolled patients underwent bone scan in the preoperative period and postoperative period respectively. Bilateral internal mammary artery was used in 8 patients (BIMA group) and single left internal mammary artery in 19 patients (LIMA group). The patients in LIMA group were divided into two groups: LlMA_skel group, in whom left internal mammary artery was harvested in skeletonized fashion (n=12), and LlMA_ped group, in whom left internal mammary artery was harvested in pedicled fashion (n=7). After the bone scan, the region of interest (ROI) was created on the left of the sternum and the mirror image with the same pixel numbers was placed on the right half of the sternum. The mean counts per pixel on the left side of the sternum was compared with those on the right side and expressed as left to right ratio (L/R ratio). Result: In LIMA group, the L/R ratio decreased from 94.6$\pm$4.1% to 87.9$\pm$6.9% (p=0.003) after the operation as compared to BIMA group, in which no change of the L/R ratio was observed. The changed of the L/R ratio in LlMA_skel group and LlMA_ped group were from 95.3$\pm$4.2% to 88.3$\pm$7.7% and from 93.4$\pm$3.9% to 87.4$\pm$5.8% respectively. The % changes in L/R ratio were -7.44 $\pm$7.08 in LIMA_skel group and -6.17$\pm$9.08 in LiMA_ped group, which did not reach the statistical difference. Conclusion: Ipsilateral sternal blood flow is interrupted by internal mammary artery harvesting as evidenced by the decrease in L/R ratio after left internal mammary artery harvesting irrespective of the harvesting techniques. Skeletonized harvesting did not show superiority in respect to sternal blood flow as compared to pedicled harvesting.