• 제목/요약/키워드: knee angle

검색결과 596건 처리시간 0.026초

스텝 에어로빅에서 박스 높이 변화에 따른 하지관절의 운동학적 분석 (The Kinematic Analysis of the Lower Extremity Joint According to the Changes in Height of Box during Step Aerobics)

  • 김규수;소재무;김윤지;여홍철
    • 한국운동역학회지
    • /
    • 제24권1호
    • /
    • pp.67-74
    • /
    • 2014
  • This study researched into the left-right inclination of the rear foot at the lower limb joints, knee joint angle, angular velocity of the knee joint, angular acceleration and the max. Based on the analysis of kinematics according to the changes in the height of step box (6, 8, 10 inches) during step aerobics of female college students majoring in physical education. The findings of this study are as follows: Then angle of the knee joint decreased as the height of the step box increased the min. Angle was measured right before the right foot was on the step box, and the angle tended to decrease as the step box get heightened. The left-right inclination of the rearfoot angle according to the height of step box increased as the height increased. In the 'pull-up' stage during which the weight was loaded on the right foot the angle increased, while in the right foot stepping stage during which the right foot was on the ground, the left-right inclination of the rearfoot angle increased as the height of the step box increased. The angular velocity of the knee joint according to the height of step box started increasing when the right foot initially stepped on the step box and during the initial stepping section, the angular velocity decreased as the height of step box increased. The changes in angular acceleration of the knee joint according to the height of step box increased as the height of step box increased.

Does Coronal Knee and Ankle Alignment Affect Recurrence of the Varus Deformity after High Tibial Osteotomy?

  • Lee, O-Sung;Lee, Seung Hoon;Lee, Yong Seuk
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.311-318
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate changes in the coronal alignment of the knee and ankle joints after open wedge high tibial osteotomy (OWHTO) to determine factors related to the recurrence (R) of the varus deformity by serial analysis. Materials and Methods: Sixty-four OWHTOs were enrolled in this study. The weight bearing line (WBL) ratio, joint line convergence angle (JLCA), knee joint inclination, mechanical axis-tibial plateau angle, talar inclination (TI), and distal tibia articular angle (DTAA) were serially assessed. Serial correlation analysis between all parameters was performed. Patients were divided into R group and no recurrence (NR) group according to the WBL ratio (55%) at postoperative one year. Results: The preoperative WBL ratio showed significantly negative correlation with serial changes of JLCA, TI, and DTAA (p<0.05). The JLCA, TI, and DTAA as well as WBL ratio showed a significantly larger degree of varus alignment in the R group than in NR group at postoperative 6 weeks and 1 year after OWHTO (p<0.05). Conclusions: Sufficient correction of the WBL and restoration of the JLCA during OWHTO are essential to prevention of the R of varus deformity after the surgery because they are the only modifiable factors during surgery. Level of Evidence: IV, Case series.

수중운동이 무릎퇴행성관절염 여성 환자에 미치는 영향 (The Effect of Aqua Exercise on Female Patients with Knee Degenerative Arthritis)

  • 박진식;유왕근;정현숙;한종만;양경한
    • 대한예방한의학회지
    • /
    • 제12권3호
    • /
    • pp.129-139
    • /
    • 2008
  • The purpose of this study was to investigate the effect of aqua exercise on women 50 years of age or older with knee degenerative arthritis, and then examining the therapeutic value of aqua exercise in degenerative arthritis of the knee. The subjects of the study were 115 residents 50 years of age or older who had been diagnosed as degenerative arthritis of the knee by doctors from medical institutions and applied for the aqua exercise program in the Public Health Care Center in Suseong-gu in 2006 and 2007. Experiments were conducted to all the subjects with the application of the 8-week aqua exercise program (2 times a week, 50 minutes a time), designed in the study, and the differences before and after the aqua exercise were compared through questionnaires for measuring the state of the body such as the knee extension angles, weight, body fat, and abdominal obesity. The data was analyzed by t-test and the Wilcoxon method through SPSS 14.0 and the statistical significance level ${\alpha}$ was set at 0.05 and 0.01. The results of the study are as the following. First, In comparison of before and after the aqua exercise, there was improvement in the extension angle of the right knee(p<0.01), while there was some improvement in the extension angle of the left knee, it was not significant. Second, In comparison of before and after the aqua exercise there were statistically significant differences in weight(p<0.05), body fat ratio, and abdominal obesity(p<0.01). The results of this study showed that the aqua exercise program to female patients with knee degenerative arthritis significantly increased the extension angle of the knee. Therefore it is thought that aqua exercise is an effective meditating method to improve their symptoms of female patients 50 years of age or older

  • PDF

Effects of the Patellar Tendon Strap on Kinematics, Kinetic Data and Muscle Activity During Gait in Patients With Chronic Knee Osteoarthritis

  • Eun-Ji Lee;Ki-Song Kim;Young-In Hwang
    • 한국전문물리치료학회지
    • /
    • 제30권2호
    • /
    • pp.110-119
    • /
    • 2023
  • Background: Osteoarthritis is a common condition with an increasing prevalence and is a common cause of disability. Osteoarthritic pain decreases the quality of life, and simple gait training is used to alleviate it. Knee osteoarthritis limits joint motion in the sagittal and lateral directions. Although many recent studies have activated orthotic research to increase knee joint stabilization, no study has used patellar tendon straps to treat knee osteoarthritis. Objects: This study aimed to determine the effects of patellar tendon straps on kinematic, mechanical, and electromyographic activation in patients with knee osteoarthritis. Methods: Patients with knee osteoarthritis were selected. After creating the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), leg length difference, Q-angle, and thumb side flexion angle of the foot were measured. Kinematic, kinetic, and muscle activation data during walking before and after wearing the orthosis were viewed. Results: After wearing the patellar tendon straps, hip adduction from the terminal stance phase, knee flexion from the terminal swing phase, and ankle plantar flexion angle increased during the pre-swing and initial swing phases. The cadence of spatiotemporal parameters and velocity increased, and step time, stride time, and foot force duration decreased. Conclusion: Based on the results of this study, the increase in plantar flexion after strap wearing is inferred by an increase due to neurological mechanisms, and adduction at the hip joint is inferred by an increase in adduction due to increased velocity. The increase in cadence and velocity and the decrease in gait speed and foot pressure duration may be due to joint stabilization. It can be inferred that joint stabilization is increased by wearing knee straps. Thus, wearing a patellar tendon strap during gait in patients with knee osteoarthritis influences kinematic changes in the sagittal plane of the joint.

절대위치 엔코더의 위치제어 알고리즘을 이용한 의지 장치의 보행 상태 추론 (Estimate of walking state of the knee disarticulation prosthesis using position control algorithm of absolute encoder)

  • 송해중;박재열;심재홍
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.1-5
    • /
    • 2013
  • 본 논문에서는 슬관절 의지 장치의 무릎 각도 제어를 통해 보행 상태를 추론하는 방법을 제안한다. 슬관절 의지의 제어에서 절대위치 엔코더를 이용해 무릎의 각도를 측정하고, 스트레인 게이지를 통해 발바닥의 부하를 측정하여 현재 보행 상태를 추론할 수 있다. 본 논문에서는 2개의 센서를 사용하여 현재 보행 상태를 4가지 상태로 추론하는 방법을 제안하였으며, 실험을 통하여 제안된 방법의 유효성을 보였다.

  • PDF

MVC 상태에서의 무릎관절 모멘트 추정을 위한 모델 개발 (Development of a Model for the Estimation of Knee Joint Moment at MVC)

  • 남윤수;이우은
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.222-230
    • /
    • 2008
  • This paper introduces a method of estimating the knee joint moment developed during MVC. By combining the Hill-type muscle model and analytic results on moment arm and musculotendon length change as a function of hip and knee joint angle, the knee joint moment at a specific knee joint angle during MVC is determined. Many differences between the estimated results and the experimental data are noted. It is believed that these differences originate from inaccurate information on the muscle-tendon parameters. The establishment of exact values for the subject's muscle parameters is almost impossible task. However, sensitivity analysis shows that the tendon slack length is the most critical parameter when applying the Hill-type muscle model. The effect of a change of this parameter on the muscle length force relationship is analyzed in detail.

닫힌 역학적 사슬운동에서 무릎관절 각도에 따른 넙다리네갈래근의 근활성도 변화 비교 (Comparison of Changes in the Muscle Activity of the Quadriceps Femoris Muscle in Relation to the Angles of the Knee Joint on Closed Kinetic Chain)

  • 안성자
    • PNF and Movement
    • /
    • 제10권3호
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose : This study was intended to compare muscle activity in relation to knee joint angles on closed kinetic chain. Methods : A total of 13 subjects consisting of 5 adult males and 8 adult females were made to make movements maintaining knee joint angles at $30^{\circ}$, $45^{\circ}$ and $90^{\circ}$ on closed kinetic chain and the muscle activity occurring in their vastus medialis, rectus femoris and vastus lateralis was measured. Statistical data were analyzed using oneway ANOVA. Results : On closed kinetic chain, the muscle activity of the vastus medialis, rectus femoris and vastus lateralis increased the most at $90^{\circ}$ among the knee joint angles with statistically significant differences(p<0.05). Conclusion : On closed kinetic chain, it could be seen that as the angle of the knee joint increased, the muscle activity increased.

운동화의 생체역학적 평가시 하지 회내운동의 운동학적 평가변인에 대한 상해 기준치 연구 (The Study on critical Value of Kinematical Evaluation Variables of Lower Extremity Pronation in Biomechanical Evaluation of Running Shoes)

  • 곽창수;전민주;권오복
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.175-187
    • /
    • 2006
  • The purpose of this study was to find the relationship between Achilles tendon angle, angular velocity from 2D cinematography utilized to easily analyze the functions of shoes, ankle joint moment, knee joint moment, and hip joint moment from 3D cinematography utilized to predict the injury. Also, this study was to provide the optimal standard to analyze the injury related to the shoes. Subjects in this study were 30 university male students and 18 conditions (2 types of running speed, 3 of midsole hardness, 3 of midsole height) were measured using cinematography and force platform. The results were as following. 1) Hip joint abduction moment was effected by many variables such as running speed, midsole height, maximum achilles tendon angle, ground reaction force. 2) Knee joint rotational moment in running was approximately 1/10 - 1/4 times of the injury critical value and eversion moment was approximately 1/4 - 1/2 times of the injury critical value. 3) Ankle joint pronation moment in running was 1/3 - 1/2 times of the injury critical value. 4) Knee joint rotational moment was found to be irrelevant with maximum achilles tendon angle or angular velocity. 5) Pronation from running was thought to be relevant to rather eversion moment activity than rotational moment activity of knee joint. 6) Plantar flexion abductor of ankle showed significant relationship with the ground reaction force variable. 7) When the loading rate for ground reaction force in passive region increased, extensor tended to be exposed to the injury. Main variables in biomechanical analysis of shoes were impact absorption and pronation. Among these variables, pronation factor was reported to be relevant with knee injury from long duration exercise. Achilles tendon angle factor was utilized frequently to evaluate this. However, as the results of this study showed, the relationship between these variables and injury relating variable of knee moment was so important. Studies without consideration on this finding should be reconsidered and reconfirmed.

Change in Kinetics and Kinematics during 1-Footed Drop Landing with an Increase in Upper Body Weight

  • Lee, Jin-Taek;David, O'Sullivan
    • 한국운동역학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2011
  • The purpose of this study was to investigate changes in kinetic and kinematic variables associated with an increase in upper body weight. Eighteen healthy male university students($175.96{\pm}4.19\;cm$, $70.79{\pm}8.26\;kg$) participated. Eight motion analysis cameras(Qualysis Oqus 500) and 2 force AMTI platforms(Advanced Mechanical Technologies Inc. OR6-7, US) were used to record motion and forces during the drop landing at a frequency of 120 Hz and 1200 Hz, respectively. QTM software(Qualisys Track Manager) was used to record the data, and the variables were analyzed with Visual 3D and Matlab 2009. For the drop landing, a box of $4{\times}2{\times}0.46\;m$ was constructed from wood. Knee and ankle maximum flexion angle, knee flexion angle, knee and ankle angle at landing, time for maximum ankle flexion after landing, and time for maximum knee flexion after landing were calculated. There was a significant change in the time for maximum and minimum ground force reaction and the time for maximum dorsal flexion after landing(p<.05) with increasing weight. There was no significant change for the hip, knee, and ankle ROM, whereas there was an increase in the angle ROM as the weight increased, in the order of ankle, knee, and hip ROM. This result shows that the ankle joint ROM increased with increasing weight for shock attenuation during the drop landing. There was a trend for greater ankle ROM than knee ROM, but there was no clear change in the ROM of the hip joint with increasing weight. In conclusion, this study shows the importance of ankle joint flexibility and strength for safe drop landing.

외측웨지인솔이 대퇴절단자의 무릎내전모멘트에 미치는 영향 (Biomechanical Effect on Knee Adduction Moment by Lateral Wedge Insole in Transfemoral Amputee)

  • 장윤희;이완희
    • 한국정밀공학회지
    • /
    • 제29권2호
    • /
    • pp.239-244
    • /
    • 2012
  • The prevalence of knee osteoarthritis was higher people with lower limb amputation. This was identified that transfemoral amputees have a greater external knee adduction moment than ablebodied subjects by biomechanical studies. Therefore, they need rehabilitative intervention for prevention and reduction of knee osteoarthritis. The purpose of this study was to determine the effect of lateral wedge insole used in the treatment of knee osteoarthritis. This study was participated in fourteen unilateral transfemoral amputees and we were analyzed the difference gait variables between without lateral wedge insole and with $5^{\circ}$ and $10^{\circ}$ lateral wedge insole during gait. Our results showed that step length ratio was more symmetrical and, hip adduction and ankle inversion angle were more close to normal value, and knee adduction moment was decreased as the wedge angle increases. We proposed that these data would be utilized conservative treatment of knee osteoarthritis in lower limb amputees.