• 제목/요약/키워드: keratoplasty

검색결과 6건 처리시간 0.018초

Autologous Lamellar Keratoplasty for the Treatment of Feline Acute Bullous Keratopathy: A Case Report

  • Manbok Jeong
    • 한국임상수의학회지
    • /
    • 제40권4호
    • /
    • pp.303-307
    • /
    • 2023
  • A 4-year-old female Munchkin cat presented with a 2-day history of a large mass in the left eye. On the first presentation, slit lamp biomicroscopy revealed a large corneal bulla occupying around 40% of the corneal surface along the visual axis. Based on the results, a diagnosis of feline acute bullous keratopathy was made. Due to the location of the extensive corneal bulla, autologous lamellar keratoplasty was performed based on prior studies, to both minimize postoperative complications that may affect axial vision and address any cosmetic concerns the owner had. The autologous lamellar keratoplasty successfully resolved the corneal bulla with no signs of corneal opacities postoperatively. Therefore, autologous lamellar keratoplasty may be a useful surgical treatment for feline acute bullous keratopathy from both the tectonic and optical points of view.

각막 압평을 이용한 로봇 바늘 삽입법: 심부표층각막이식수술에의 적용 (Robotic Needle Insertion Using Corneal Applanation for Deep Anterior Lamellar Keratoplasty)

  • 박익종;신형곤;김기훈;김홍균;정완균
    • 로봇학회논문지
    • /
    • 제16권1호
    • /
    • pp.64-71
    • /
    • 2021
  • This paper describes a robotic teleoperation system to perform an accurate needle insertion into a cornea for a separation between the stromal layer and Descemet's membrane during deep anterior lamellar Keratoplasty (DALK). The system can reduce the hand tremor of a surgeon by scaling the input motion, which is the control input of the slave robot. Moreover, we utilize corneal applanation to estimate the insertion depth. The proposed system was validated by performing the layer separation using 25 porcine eyes. The average depth of needle insertion was 742 ± 39.8 ㎛ while the target insertion depth was 750 ㎛. Tremor error was reduced from 402 ± 248 ㎛ in the master device to 28.5 ± 21.0 ㎛ in the slave robot. The rate of complete success, partial success, and failure were 60, 28, and 12%, respectively. The experimental results showed that the proposed system was able to reduce the hand tremor of surgeons and perform precise needle insertion during DALK.

개의 건성각결막염에 의한 각막천공을 안구내용물적출술과 실리콘볼 삽입 후 각막이식을 적용하여 치료한 증례 (Evisceration and Intrascleral Silicone Ball Prosthesis with Penetrating Keratoplasty on Perforated Corneal Ulcer Secondary to KCS in a Shih Tzu Dog)

  • 김종민;김종열;김황민;장세웅;정인성;최석화
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.356-358
    • /
    • 2015
  • 큰 크기의 각막천공에 안내용물 손상이 된 눈을 안구적출술을 시도하지 않고, 안구내용물적출술과 실리콘볼 삽입후 각막이식을 적용하여 치료하여 안구적출술보다 미용상 만족한 눈의 외관을 얻은 증례를 소개 하였다.

전층각막이식을 시행한 안에서 리바운드 안압계의 임상적 유용성 (Clinical Evaluation of a Rebound Tonometer in Patients Who Underwent Penetrating Keratoplasty)

  • 김종우;정지원
    • 대한안과학회지
    • /
    • 제59권12호
    • /
    • pp.1122-1128
    • /
    • 2018
  • 목적: 전층각막이식을 시행받은 환자에서 리바운드 안압계의 임상적 유용성을 골드만 안압계 및 비접촉 안압계와 비교하여 알아보고자 하였다. 대상과 방법: 전층각막이식을 시행한 19안, 정상 대상자의 28안을 대상으로 하였다. 전층각막이식을 시행한 안과 정상안 각각에서 리바운드 안압계로 측정한 안압 결과를 골드만 안압계와 비접촉 안압계로 측정한 결과와 Spearmann 상관분석을 시행하고 Wilcoxon signed rank test 검정을 사용하여 비교하였다. 또한 각 그룹에서 리바운드 안압계로 측정한 안압 결과를 급내상관계수를 이용하여 재현성을 평가하였다. 결과: 정상안에서는 리바운드 안압계로 측정한 결과가 골드만 및 비접촉 안압계로 측정한 결과값과 유의한 차이가 없었다(p>0.050). 전층각막이식을 시행한 안에서는 리바운드 안압계로 측정한 안압은 골드만 안압계로 측정한 안압과 유의한 차이를 보이지 않았으나(p=0.872), 비접촉 안압계로 측정한 안압에 비하여 유의하게 낮았다(p=0.011). 하지만 리바운드 안압계로 측정한 안압과 골드만 및 비접촉 안압계로 측정한 안압은 비교적 높은 상관성을 보였다(r=0.770, 0.879). 리바운드 안압계 측정치의 급내상관계수는 전층각막 이식을 시행한 안에서는 0.986, 정상안에서는 0.961로 두 군 모두 높은 재현성을 보였다. 결론: 전층각막이식을 시행한 안에서 리바운드 안압계 측정값은 골드만 및 비접촉 안압계 측정값과 비교적 높은 상관성을 보였으며 정상안과 유사하게 높은 재현성을 보여 이들 환자의 안압 측정에 있어서 유용한 방법 중 하나로 생각해 볼 수 있다.