• Title/Summary/Keyword: kVCT

Search Result 22, Processing Time 0.03 seconds

New Multi-Function Sizing Centre (MFC)

  • Rundel, Albert;Rauch, Peter
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.745-746
    • /
    • 2006
  • This lecture introduces new press, adapter and control concepts to size multi-level sintered components. The essential thing here is that the advantages of the multi-plate technology have been applied to the sizing adapter concept. Thus, the new concept meets the demands for a modern P/M manufacture and offers sufficient potential to size any future, complex sintered components such as synchronizer hubs, oil pump wheels and VCT parts with highest precision. Furthermore, it outlines a new flexible concept for the parts transfer, including feeding, orientation and lubrication while responding to the high demands on process stability and short change-over times.

  • PDF

Pharyngeal airway analysis of different craniofacial morphology using cone-beam computed tomography (CBCT) (Cone beam CT를 이용한 안면골격형태에 따른 상기도 공간 분석)

  • Kim, Yong-Il;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.136-145
    • /
    • 2009
  • Objective: CBCT has become popular for orthodontic diagnosis and treatment planning in recent times. The 3D pharyngeal airway space needs to be analysed using a 3D diagnostic tool. The aim of this study was to analyse the pharyngeal airway of different craniofacial morphology using CBCT. Methods: The sample compromised 102 subjects divided into 3 groups (Class I, II, III) and 6 subgroups according to normal or vertical craniofacial patterns. All samples had CBCT (VCT, Vatech, Seoul, Korea) taken for orthodontic treatment. The pharyngeal airway was assessed according to the reference planes: aa plane (the most anterior point on the anterior arch of atlas), $CV_2$ plane, and $CV_3$ plane (most infero-anterior point on the body of the second & third cervical vertebra). The intergroup comparison was performed with one-way ANOVA and duncan test as a second step. Results: The results showed the pharyngeal airway and anteroposterior width of group 2 (Class II) in aa plane, $CV_2$ plane, $CV_3$ plane were significant narrower than in group 3 (Class III). There was no significant difference between vertical and normal craniofacial patterns except for the anteroposterior pharyngeal width of Group 1 (Class I) in aa plane. Conclusions: Subjects with Class II patterns have a significantly narrower pharyngeal airway than those with Class III. However there was no difference in pharyngeal airway between vertical and normal craniofacial morphology.

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA (심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jong-Seon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT (MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성)

  • Park, Soo Ho;Shim, Jeong Su;Lee, Sang Kon;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

A Study on Interior Flooring Materials for Safe Elderly Nursing Home Environment (안전한 노인요양시설 환경을 위한 실내 바닥마감재에 관한 연구)

  • Chung, Miryum
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.19-26
    • /
    • 2014
  • The number of elderly who wants to access to Nursing Homes (NH) will increase due to the rapid aging society and domestic changes. Those who move into NH expect 24/7 care service in safe environment. Providing space free from danger, especially from fall, for the frail elderly is essential. The purpose of this study is to categorize performance needs of flooring materials in the aspect of safety, and analyze materials so that adequate ones for each space in NH can be suggested. Performance needs are as follows; slip resistance (dry/wet), fire resistance, resilience, water resistance, soil retardant, anti-bacterial, gloss, sound absorbtion. maintenance, durability, ease replacement, color and pattern variety, visual and tactual texture, tactile warmth, IAQ, sustainable material (before use), impact to nature (after use). They are categorized under function, economy, sensibility and sustainability. It was found that there are better materials than common ones that has been used repeatedly in NHs, such as vinyl sheets and VCT. In overall, Cork flooring and nylon carpet met all four categories, followed by wool carpet, rubber and linoleum. For bedroom, wood flooring, Cork, rubber, wool carpet, nylon carpets were suggested. In bathroom with shower, rubber, vinyl sheet and porcelain tiles were safe materials. As living/dining room and corridor floors, wool carpet, nylon carpet, cork flooring would be excellent as they are resilient and durable. The result of this paper can be used by both NH managers and material companies, resulting better quality of life of the elderly by providing safe environment.

Ultrastructural Studies of Oogenesis and Oocyte Degeneration in Female Ruditapes philippinarum (Bivalvia: Veneridae) from Gomso Bay, Korea (곰소만에 서식하는 암컷 바지락 Ruditapes philippinarum의 난형성과정 및 난모세포 퇴화의 미세구조적 연구)

  • Lee, Ki-Young;Chung, Ee-Yung
    • Development and Reproduction
    • /
    • v.12 no.1
    • /
    • pp.41-49
    • /
    • 2008
  • Ultrastructural changes occurring during the course of development and degeneration of oocytes in female Ruditapes philippinarum (Adams & Reeve, 1850) are described for clams collected from Gomso Bay, Korea. During the early stages of oogenesis, desomosome-like gap junctions localized between the early vitellogenic oocyte and the follicle cells. Vitellogenesis occurs through a process of autosynthesis, involving the combined activity of the Golgi complex, mitochondria and rough endoplasmic reticulum, and heterosynthesis in which extraovarian precursors are incorporated into oocytes by endocytotic activity, involving the basal region of the early vitellogenic oocytes prior to the formation of the vitelline envelope. The follicle cells appear to play an integral role in vitellogenesis and oocyte degeneration: phagocytosis and intracellular digestion of products originating from oocyte degeneration. These functions can permit a transfer of yolk precursors necessary to vitellogenesis, and they can accumulate nutrients in the cytoplasm, as glycogen and lipids, which can be employed by the vitellogenic oocyte. During the period of oocyte degeneration, follicle cells may have lysosomal system for breakdown, and resorb various phagosomes in the cytoplasm for nutrient storage. But follicle cells probably are not the major source of yolk precursors in vitellogenesis.

  • PDF

Analysis of Automatic Rigid Image-Registration on Tomotherapy (토모테라피의 자동영상정합 분석)

  • Kim, Young-Lock;Cho, Kwang Hwan;Jung, Jae-Hong;Jung, Joo-Young;Lim, Kwang Chae;Kim, Yong Ho;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Suh, Tae Suk;Choe, Bo-Young;Min, Jung-Whan;Ahn, Jae Ouk
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2014
  • The purpose of this study was to analyze translational and rotational adjustments during automatic rigid image-registration by using different control parameters for a total of five groups on TomoTherapy (Accuray Inc, Sunnyvale, CA, USA). We selected a total of 50 patients and classified them in five groups (brain, head-and-neck, lung, abdomen and pelvic) and used a total of 500 megavoltage computed tomography (MVCT) image sets for the analysis. From this we calculated the overall mean value(M) for systematic and random errors after applying the different control parameters. After randomization of the patients into the five groups, we found that the overall mean value varied according to three techniques and resolutions. The deviation for the lung, abdomen and pelvic groups was approximately greater than the deviation for the brain and head-and-neck groups in all adjustments. Overall, using a "full-image" produces smaller deviations in the rotational adjustments. We found that rotational adjustment has deviations with distinctly different control parameters. We concluded that using a combination of the "full-image" technique and "standard" resolution will be helpful in assisting with patients' repositioning and in correcting for set-up errors prior to radiotherapy on TomoTherapy.

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF