• Title/Summary/Keyword: kVA rating

Search Result 28, Processing Time 0.017 seconds

Effect of Winding Configuration on the kVA Rating of Wye-connected Autotransformer Applied to 12- pulse Rectifier

  • Meng, Fangang;Du, Qingxiao;Gao, Lei;Li, Quanhui;Man, Zhongcheng
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.463-474
    • /
    • 2019
  • This paper presents the effect of winding configuration on the kVA rating of a wye-connected autotransformer applied to a 12-pulse rectifier. To describe the winding configuration of the wye-connected autotransformer, position and proportional parameters are defined and their quantitative relation is calculated. The voltages across and currents through the windings are measured under different winding connections. Consequently, a relation between the kVA rating and position parameter is established in accordance with the analysis, and the optimal winding configuration is obtained on the basis of this relation. A wye-connected autotransformer with the least equivalent kVA rating and simplest winding configuration is designed and applied to the 12-pulse rectifier. Simulations and experiments are conducted to validate the theoretical analysis.

Empirical Bayes Estimation and Comparison of Credit Migration Matrices (신용등급전이행렬의 경험적 베이지안 추정과 비교)

  • Kim, Sung-Chul;Park, Ji-Yeon
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.443-461
    • /
    • 2009
  • In order to overcome the lack of Korean credit rating migration data, we consider an empirical Bayes procedure to estimate credit rating migration matrices. We derive the posterior probabilities of Korean credit rating transitions by utilizing the Moody's rating migration data and the credit rating assignments from Korean rating agency as prior information and likelihood, respectively. Metrics based upon the average transition probability are developed to characterize the migration matrices and compare our Bayesian migration matrices with some given matrices. Time series data for the metrics show that our Bayesian matrices are stable, while the matrices based on Korean data have large variation in time. The bootstrap tests demonstrate that the results from the three estimation methods are significantly different and the Bayesian matrices are more affected by Korean data than the Moody's data. Finally, Monte Carlo simulations for computing the values of a portfolio and its credit VaRs are performed to compare these migration matrices.

Series Hybrid Active Filter

  • Kim, Won-Ho;Kim, Jong-Soo;Kang, Iou-Ri;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.271-273
    • /
    • 1995
  • Hybrid active filters utilize passive filters to reduce the voltage rating and hence the VA rating of the active filter converter. A novel hybrid active filter topoloty to minimize utility current harmonics at high power levels is presented in this paper. The proposed topology combines both passive and active filters to obtain the lowest converter VA rating as compared to the converter rating in the active filter and the series-active hybrid filter configurations. This is demonstrated with experimental results from a laboratory model. Simulation results showing the effect of passive filter impedance are presented.

  • PDF

Operation and Performance Analysis of New Bidirectional Intelligent Semiconductor Transformer (새로운 양방향 지능형 반도체 변압기의 동작과 성능 분석)

  • Kim, Do-Hyun;Lee, Byung-Kwon;Han, Byung-Moon;Lee, Jun-Young;Choi, Nam-Sup
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.169-177
    • /
    • 2013
  • This paper proposes a new configuration of bidirectional intelligent semiconductor transformer with rating of 1.9kV/127V, 2kVA. The proposed transformer consists of high-voltage high-frequency AC-DC rectifier, and low-voltage DC-DC and DC-AC converters. The operational feasibility of proposed transformer was verified by computer simulation with PSCAD/EMTDC software. Based on the simulation results, a hardware prototype with rating of 1.9kV/127V, 2kVA was built and tested in the lab to confirm the feasibility of hardware implementation. Using three units of this transformer, a 3-phase transformer with rating of 3.3kV/220V, 6kVA can be built.

A Study of Output Filter Design for Current/Voltage Source Converter in High-Power Hybrid System (전류형/전압형 컨버터를 이용한 대전력 하이브리드시스템용 출력필터 구조 연구)

  • Kim, Tae-Sik;Kwak, Sang-Shin;Kwon, Woo-Hyen
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.228-230
    • /
    • 2009
  • 본 논문에서는 전류형 인버터(CSI)와 전압형 인버터(VSI)를 조합하여 유도성 부하에 정현파 전류를 공급하는 시스템에서, LC 소자를 추가함으로써 전압형 인버터의 VA rating을 줄일 수 있는 방법을 제안하였다. 전력제어용 스위칭 소자인 SCR은 대용량인 장점이 있는 반면에 턴오프 제어가 되지 않고, 비선형 특성으로 인해 고조파가 발생한다. 이러한 단점을 개선하기 위해 전압형 인버터를 사용하여, SCR를 OFF하고 부하에 정현파 전압/전류를 제공한다. 또한, 출력단에 수동 LC 필터를 추가하여 전압원 인버터의 VA rating을 저감시키는 구조를 연구하고 이를 Psim을 이용한 시뮬레이션을 통해 검증하였다.

  • PDF

A Study on the Thermal distribution of the 30kVA Pole Transformer Due to the Rated load (30kVA 주상 변압기의 정격부하에 의한 열분포에 관한 연구)

  • Kim, M.K.;Kim, J.T.;Koo, J.Y.;Song, K.D.;Cho, Y.O.;Ha, B.N.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.292-295
    • /
    • 1991
  • The life of the transformers is significantly dependent upon the rate of thermal deterioration in the employed insulating materials. Therefore, the study should be based on hot-spot temperature considerations for the life expectancy and possible overload of transformer. We have measured directly temperature of the winding using thermocouples and these test results are compared with those obtained from computer simulation. In this work, our fundamental investigations are well described for the analysis in the thermal distribution of the oil-immersed transformer with the rating of 30kVA.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • ;Prasad N.Enjeti
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

A New 24-Pulse Diode Rectifier for High Voltage and High Power Application (새로운 고전압 대전력용 24펄스 다이오드 정류기 시스템)

  • 최세완;김기용
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.304-309
    • /
    • 1999
  • In this paper, a new 24longleftarrowpulse diode rectifier system based upon the conventional series-connected 12-pulse rectifier is p proposed with the least number of switching devices and low VA rating of the additional passive components. The p proposed approach does not employ any active switching devices. Therefore, the system is rugged and simple to i implement. Detailed analysis with VA rating calculation of the components is presented and experimental results from a a 220V, 3kV A rectifier system verify the proposed concept.

  • PDF

Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems

  • Kim, Sangsoon;Jahng, Seungmin;Yu, Kyung-Ho;Lee, Byung-Chul;Kang, Yeonwook
    • Dementia and Neurocognitive Disorders
    • /
    • v.17 no.3
    • /
    • pp.100-109
    • /
    • 2018
  • Background and Purpose: Although the clock drawing test (CDT) is a widely used cognitive screening instrument, there have been inconsistent findings regarding its utility with various scoring systems in patients with mild cognitive impairment (MCI) or dementia. The present study aimed to identify whether patients with MCI or dementia exhibited impairment on the CDT using three different scoring systems, and to determine which scoring system is more useful for detecting MCI and mild dementia. Methods: Patients with amnestic mild cognitive impairment (aMCI), vascular mild cognitive impairment (VaMCI), mild Alzheimer's disease (AD), mild vascular dementia (VaD), and cognitively normal older adults (CN) were included. All participants were administered the CDT, the Korean-Mini Mental State Examination (K-MMSE), and the Clinical Dementia Rating scale. The CDT was scored using the 3-, 5-, and 15-point scoring systems. Results: On all three scoring systems, all patient groups demonstrated significantly lower scores than the CN. However, while there were no significant differences among patients with aMCI, VaMCI, and AD, those with VaD exhibited the lowest scores. Area under the Receiver Operating Characteristic curves revealed that the three CDT scoring systems were comparable with the K-MMSE in differentiating aMCI, VaMCI, and VaD from CN. In differentiating AD from CN, however, the CDT using the 15-point scoring system demonstrated the most comparable discriminability with K-MMSE. Conclusions: The results demonstrated that the CDT is a useful cognitive screening tool that is comparable with the Mini-Mental State Examination, and that simple CDT scoring systems are sufficient for differentiating patients with MCI and mild dementia from CN.

Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer (50[kVA] 몰드변압기 권선부의 열전달 특성 해석)

  • 이현진;정중일;허창수;조한구
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.47-54
    • /
    • 2002
  • This paper presented the charcteristic of the thermal transfer in a 50[kVA] cast-resin dry type transformer. The conductivity of the primary winding composed were a Plenty of epoxy-resin ard a little of Cu was determined by that rating. Otherwise the conductivity of the secondary winding composed of a plenty of Cu and a little of epoxy-resin was determined by comparing the data of analysis using FEM method with those of temperature tests of the prototype cast-resin transformer. Based on the reults of the physical characteristics and the simulation by commercial using FEM method we established the prototype Model for this test. According to that Model, an analysis on variation of the temperature was discussed as a function of ambient temperature and velocities in the 50[kVA] cast-resin dry type transformer.