Antioxidant Activity and Quality Characteristics of Yogurt Added Green Olive Powder during Storage

  • Cho, Won-Young;Yeon, Su-Jung;Hong, Go-Eun;Kim, Ji-Han;Tsend-Ayush, Chuluunbat;Lee, Chi-Ho
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.865-872
    • /
    • 2017
  • The objective of this study was to determine the antioxidant and quality characteristics of yogurt added green olive powder stored at $4^{\circ}C$ for 15 d. The following four groups were used in this study: Control group (GY0), Yogurt added with 1% green olive (GY1), with 3% green olive (GY3), and with 5% green olive (GY5). The more time of titratable acidity went by, the more it increased. Except GY0, viscosity tended to decrease in other groups (p>0.05), and the more time of syneresis went by, the more it increased, but GY3 of them showed the lowest syneresis. Lactic acid bacteria showed no significant with GY0 until 5 d, but after that, GY1, GY3 and GY5 showed lower than GY0. Yogurt added green olive showed darker color than GY0 (low $L^*$ and high $a^*$). The antioxidant activity of GY5 was found to be the highest among the four groups at day 1 of storage. Total phenolic content, 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity, and reducing power of GY5 was found to be the highest among the four groups at day 1 of storage which were 6.96 mg GAE/kg, 47.53%, and 0.57, respectively. In the sensory evaluation sweet and overall of GY3 indicated the highest score among the four groups. Results of this study demonstrated that green olive powder might be used to improve the antioxidant capacity and sensory characteristics of yogurt.

Serum enzymes as indicators of radiation exposure in rat (흰쥐의 방사선 피폭후 생물학적 지표로서의 혈액효소)

  • Kim, In-Gyu;Kim, Sang-Bok;Kim, Jin-Gyu;Kim, Kug-Chan;Chun, Ki-Chung;Park, Hyo-Kook;Lee, Kang-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.37-45
    • /
    • 1993
  • Enzyme activity changes in rat blood as biochemical indicator useful for evaluating exposure dose were experimentally studied. The experimental results obtained are as follows: 1) Alkaline phosphatase activities increased in the blood serum until 24 hours after 0.1, 0.25, 0.5, 2 and 4Gy irradiation and its activities returned normal condition after 72 hours of post-irradiation. Creatine kinase activities increased in the blood serum until 72 hours after 2 and 4Gy irradiation but any significant activity changes were not detected after 0.1, 0.25Gy irradiation. 2) Malate dehydrogenase activities did not reveal available changes after 0.1, 0.25, 0.5 Gy irradiation and lactate dehynrogenase activities decreased in the blood serum after 0.1, 0.25, 0.5 Gy irradiation.3) Glutamate oxaloacetate transaminase activity changes were detected in the blood serum after 0.1, 0.25, 0.5, 2, 4Gy(0.1Gy/min.) and GOT activities increased after 0.5, 1, 1.5, 2, 3, 5, 7Gy(0.5Gy/sec.). Any acid phosphatase activities were detected in the blood serum after 0.1, 0.25, 0.5, 2, 4Gy(0.1Gy/min.) and 0.5, 1, 1.5, 2, 3, 5, 7Gy(0.5 Gy/sec.) irradiation. Potentially some of these enzymes can be used as indicator protein for radiation injury. Futher investigation is needed to find better biochemical indicators utilizing recent know-ledge and techniques of biochemistry.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

Control of Insects on Stored Rice Grain by Gamma Irradiation (곡류의 해충 구제를 위한 감마선의 이용)

  • Byun, Myung-Woo;Kwon, Joong-Ho;Cha, Bo-Sook;Chung, Kyu-Hoi;Cho, Han-Ok
    • Applied Biological Chemistry
    • /
    • v.31 no.2
    • /
    • pp.143-146
    • /
    • 1988
  • The effect of gamma irradiation on controlling infestation of insects on rice grain were investigated. The egg and larva stages of rice weevil (Sitophilus oryzae) were more radiosensitive than the pupal and adult stages. The complete mortal dose of the first two stages was 0.05kGy, while it was 0.5kGy in the second two stages. In indian-meal moth (plodia interpuctella Hubner), sterile doses of egg, larva, pupa and adult were 0.04 to 0.05, 0.05 to 0.06 and 0.2 to 0.25kGy, respectively. Therefore, the irradiation dose within 1.0kGy was considered to be effective for rice storage so far as reinfestation was prevented. Attractiveness of indian-meal moth toward the rice irradiated at 1.0 to 5.0kGy was non-significant in F-test.

  • PDF

Elimination of Microorganisms Contaminated in Red Ginseng Powder by Irradiation Processing (감마선 조사를 이용한 홍삼분말의 오염미생물 제거)

  • Yook, Hong-Sun;Kim, Seong-Ai;Byun, Myung-Woo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.366-370
    • /
    • 1996
  • Gamma irradiation was applied to red ginseng powder for improving its hygienic quality 7.5 kGy of gamma irradiation completely eliminated the microorganisms contaminated in red ginseng powder. And there was no growth of microorganisms after six months of storage at room temperature. The molds isolated from red ginseng powder were identified as Pen. commune, Asp. niger, Asp. versicolor and Asp. Unguis, the conidia of which showed the decimal reduction dose ($D_{10}$ value) of 0.37-0.50 kGy, 0.24-0.31 kGy, 0.25-0.36 kGy and 0.28-0.41 kGy and inactivation factor of 5.0-6.5, 7.4-9.3, 6.5-9.1 and 6.1-8.4, respectively The radiosensitivity of identified molds' conidia decreased in medium containing red ginseng extract.

  • PDF

Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients (유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가)

  • Jung, In Ho;Kim, Joon Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • Purpose : We investigated the safety of Intrabeam$^{TM}$ system, X-ray unit for Intraoperative Radiotheray (IORT) by measuring surface dose using Optically Stimulated Luminescent Dosimeter(OSLD). Materials and Methods : 30 patients were selected, who were in breast cancer patients and had an operation of breast conserving surgery (BCS). At the inner surface of tumor bed, 20 Gy were described, and 5 Gy at 1cm depth from the inner surface. Along the size of tumor bed which could be decided after resection of tumor, the size of applicator were determined. Usual treatment time were from 18 to 40 minutes. For the measurement of surface doses, OSLD were placed at superior(U1,2), inferior(D1,2), lateral(L1,2) and medial(M1,2) directions from the center of applicator. Each direction, two OSLD were placed at 0.5 cm and 1.5 cm from the center. Mean, maximum, and minimum doses were analyzed to be compared. Results : Mean values were U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, and M2 $1.51{\pm}0.58Gy$. Maximum values were 4.34 Gy at U1, and Minimum values were 0.45 Gy at M2. 13.3 % of patient (4pts out of 30) were reported that surface dose were over 4 Gy. Conclusion : The fact that skin dose of all patients were less than 5 Gy based on OSLD measurement showed the safety of Intrabeam$^{TM}$ system. In the relatively small breast volume, the tendency that surface dose was increased had been shown, which was analyzed by the data of patients who irradiated over 4Gy at skin surface. Therefore, for appropriate indication for IORT, it is suggested that breast volume as well as the size and position of tumor should be carfully considered.

  • PDF

Effect of Low-Dose Gamma Radiation to Enhance Germination Rate in Bottle Gourd and Pumpkin Seeds (참박과 호박 종자의 발아촉진을 위한 저선량 감마선의 효과)

  • Kim, Jae-Sung;Baek, Myung-Hwa;Lee, Young-Keun;Lee, Hae-Youn;Yoo, Jun-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.202-207
    • /
    • 2002
  • To establish the seed treatment method of the gamma radiation for germination enhancement of bottle gourd(Lagenaria siceraria Standl.) and pumpkin(Cucurbita ficifolia Bouche), seeds were irradiated with the dose of 1$\sim$20 Gy of the gamma radiation. The germination rate in irradiated group was higher than that of the control, depending on seed condition. In the case of bottle gourd, the germination rate of 70$\sim$80% germinative seed was increased at 4$\sim$20 Gy irradiated groups. Especially, it was the highest at 4 Gy irradiated group. The germination rate of 80$\sim$90% germinative seed was the highest at 4 Gy irradiated group. The germination rate of 70$\sim$80% and 80$\sim$90% germinative seed at 4 days after sowing was increased 66% and 26% at 4 Gy irradiated group, respectively. In the case of pumpkin, the germination rate of 70$\sim$80% and 80$\sim$90% germinative seed was increased at 2 Gy and 8 Gy irradiated group, respectively. Effect of the low-dose gamma radiation on the early growth was enhanced depending on their germination enhancement. Especially, it was the highest at 2 Gy irradiated group of 70$\sim$80% germinative seed of pumpkin. Catalase activity of bottle gourd was increased at 4 Gy irradiated group. Catalase and peroxidase activity of pumpkin were increased at 2 Gy and 8 Gy irradiated group. These results suggest that the germination, early growth and physiological activity of bottle gourd and pumpkin seeds could be promoted by the low dose gamma radiation.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Comparison of Dose Distribution between the Techniques of Non-small Cell Lung Cancer (비소세포폐암의 방사선 치료기법간의 선량분포의 비교)

  • Lee, Seung-chul;Kim, Young-jae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.233-239
    • /
    • 2016
  • Comparison of the dose aspect that radiation therapy treatments using IMRT, tomotherapy, mArc (modulated arc therapy). The experimental subject is non-small cell lung cancer patient. The prescription dose is 58.0 Gy to the volume of PTV(planning target volume). and spinal cord, esophagus, and liver organ is the normal organ(OAR, organ at risk). Average PTV value is 57.60 Gy in mArc and 61.04 Gy in tomotherapy and 58.95 Gy in IMRT. The average dose of the Esophagus is 2.84 Gy in m-Arc, 5.14 Gy in tomotherapy, 1.84 Gy in IMRT. The average dose of the Liver is 19.44 Gy in m-Arc, 12.22 Gy in tomotherapy, 21.97 Gy in IMRT. The average dose of the Spinal cord is 5.72 Gy in m-Arc, 7.08 Gy in tomotherapy, 6.15 Gy in IMRT. Results of this study is no significant difference between mArc and tomotherapy and Linac based IMRT in dose study and also, mArc's dose coverage and dose volume histogram is better than IMRT and tomotherapy. but, This study is limited to a disease of cancer. in addition, fewer number of groups. The wide range the more research can be developed patient-specific treatment techniques and be applied to the patients

The Characteristics of Thermoluminescence from $^{137}$ Cs Irradiated Beta-Eucryptite ($^{137}$ Cs으로 조사된 베타-유크립타이트의 열자극발광 특성)

  • 김태규;이병용;박영우;추성실;황정남
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.23-31
    • /
    • 1992
  • The thermally stimulated luminecence (Thermoluminescence:TL) of manufactured beta-eucryptite was studied for dose range of 200cGy-20000Gy. The TL spectrum from cesium irradiated beta-eucryptite was measured over the temperature range of 300K to 600K. The linearity of TL intensity vs irradiation dose is valid up to 50Gy and beyond higher dose supralinearity and saturation come out. At the dose of 2000Gy, the net number of supralinearity is maximum. The net amount of supralinearity form newly formed trapping center by photon irradiation and totally calculated TL intensity are accord with the experimental results except for the 50Gy range that supralinearity appears.

  • PDF