• Title/Summary/Keyword: k-configuration

Search Result 5,478, Processing Time 0.037 seconds

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Analysis of Complications Associated with the Nuss Procedure: Risk Factors and Preventive Measures (너스수술의 합병증에 대한 고찰: 위험인자 분석과 예방책의 제시)

  • Park, Hyung-Joo;Chang, Won-Ho;Jeon, Cheol-Woo;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.524-529
    • /
    • 2004
  • Background: Since the Nuss procedure for the correction of pectus excavatum is in its early stage, there have been problems that need to be solved. We examined complications in a single-institute experience of the Nuss technique in order to develop possible solutions to prevent them. Material and Method: 335 consecutive patients, who underwent the modified Nuss procedure between August 1999 and October 2002, were studied retrospectively. Median age was 8 years (range 1 to 46). 264 patients (78.8%) were in pediatric group (age$\leq$15) and 71 patients (21.2%) were in adult group (age> 15). 193 patients (57.6%) had symmetric and 142 patients (42.4%) had asymmetric pectus configurations. Risk factors predicting postoperative complications were analyzed using multi-variate logistic regression. Result: Postoperative complication rates were 18.9% (61/335) in total patients. Frequent complications were pneumothorax 24 (7.5%), bar displacement 11 (3.4%), and wound seroma 10 (3.1%) in order. Early complications (within a month, 49 cases, 15.2%) were pneumothorax (n=23, 6.9%), wound seroma (n=12, 3.6%), and bar displacement (n=8, 2.4%). Late complications (after a month, 12 cases, 3.7%) were pericarditis and pericardial effusion (n=5, 1.5%), bar displacement (n=4, 1.2%), and hemothorax (n=3, 0.9%). Techniques were modified to prevent complications especially in bar shaping and fixation, which led to decrease complication rate in later experience (Operation Date 1: 15/51 (29.4%) vs Operation Date 2: 34/284 (12.0%), p=0.004). Grand Canyon type (eccentric long canal type) showed higher complication rate than other types (GC type: 12/30(40%) vs Others: 37/305 (12.1%), p<0.001). Major risk factors are severity of pectus (OR=2.88, p=0.038), Grand Canyon type (OR=2.82, p=0.044), and Op. Date 1 (OR=4.05, p=0.001). Conclusion: Major complications were related to severe eccentric type of pectus configuration (Grand Canyon type) and lack of surgeon's experience (Op. Date 1). Com-plication rate was reduced with accumulation of experience and advancement of surgical techniques. The Nuss procedure can be performed at a low risk of complications with our current technique.

A Knowledge-based Approach for the Estimation of Effective Sampling Station Frequencies in Benthic Ecological Assessments (지식기반적 방법을 활용한 저서생태계 평가의 유효 조사정점 개수 산정)

  • Yoo, Jae-Won;Kim, Chang-Soo;Jung, Hoe-In;Lee, Yong-Woo;Lee, Man-Woo;Lee, Chang-Gun;Jin, Sung-Ju;Maeng, Jun-Ho;Hong, Jae-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Decision making in Environmental Impact Assessment (EIA) and Consultation on the Coastal Area Utilization (CCAU) is footing on the survey reports, thus requires concrete and accurate information on the natural habitats. In spite of the importance of reporting the ecological quality and status of habitats, the accumulated knowledge and recent techniques in ecology such as the use of investigated cases and indicators/indices have not been utilized in evaluation processes. Even the EIA report does not contain sufficient information required in a decision making process for conservation and development. In addition, for CCAU, sampling efforts were so limited that only two or a few stations were set in most study cases. This hampers transferring key ecological information to both specialist review and decision making processes. Hence, setting the effective number of sampling stations can be said as a prior step for better assessment. We introduced a few statistical techniques to determine the number of sampling stations in macrobenthos surveys. However, the application of the techniques requires a preliminary study that cannot be performed under the current assessment frame. An analysis of the spatial configuration of sampling stations from 19 previous studies was carried out as an alternative approach, based on the assumption that those configurations reported in scientific journal contribute to successful understanding of the ecological phenomena. The distance between stations and number of sampling stations in a $4{\times}4$ km unit area were calculated, and the medians of each parameter were 2.3 km, and 3, respectively. For each study, approximated survey area (ASA, $km^2$) was obtained by using the number of sampling stations in a unit area (NSSU) and total number of sampling stations (TNSS). To predict either appropriate ASA or NSSU/TNSS, we found and suggested statistically significant functional relationship among ASA, survey purpose and NSSU. This empirical approach will contribute to increasing sampling effort in a field survey and communicating with reasonable data and information in EIA and CCAU.

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Clinical Investigation of 11 Cases of Chronic Eosinophilic Pneumonia Reported in Korea (국내에서 보고된 만성 호산구성 폐렴 11예에 대한 임상적 고찰)

  • Woo, Ka-Eun;Chang, Jung-Hyun;Choi, Young-Ah;Joo, Mi-Soon;Seo, Ki-Youl;Shin, Tae-Rim;Cheon, Sean-Hee;Cho, Young-Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.107-115
    • /
    • 1998
  • Background: Chronic eosinophilic pneumonia(CEP) presents with profound systemic symptoms, including fever, malaise, night sweats, weight loss, and anorexia together with localized pulmonary manifestations such as cough, wheeze, and sputum. It is an illness occurring predominantly in women. The chest radiogragh shows fluffy opacities that often have a characteristic peripheral configuration. The hallmark of CEP is the peripheral blood eosinophilia and a prompt response to oral corticosteroid therapy. We investigated characteristics of eleven patients of chronic eosinophilic pneumonia, reported in Korea. Method: There were eleven reports of CEP from 1980 to 1996, including three cases experienced in our hospital. The journals were analysed in respects of clinical history, laboratory, and radiographic findings. Results: 1) Male vs. female ratio is 3 : 8. The peak incidence occurred in forty and fifty decades. The atopic diseases were present in 6 cases. Asthma was the commonest manifestation 2) The presenting symptoms were as follows: cough, dyspnea, sputum, weight loss, fever, general weakness, night sweats, urticaria with the descending incidence. 3) Peripheral blood eosinophilia was present in all patients(mean ; 38.4%) and serum IgE level was elevated in nine patients(mean ; 880IU/ml). Conclusion: The diagnosis of chronic eosinophilic pneumonia is based on classic symptoms, including fever, night sweats, weight loss with a typical roentgenogram of peripheral pulmonary infiltrates and peripheral blood eosinophilia, and that is confimed by lung biopsy and/or bronchoalveolar lavage. Chronic eosinophilic pneumonia is responsive to corticosteroid promptly and recommended at least 6 months of therapy to prevent relapse.

  • PDF

Development and Usefulness of Acrylic Needle for Percutaneous Bone Biopsy (경피적 골생검용 아크릴 바늘의 제작과 유용성)

  • Kim, Tae-Hyung;Shin, Myung-Jin;Shin, Ji-Hoon;Lim, Jin-Oh;Ryu, Ji-Yeon;Oh, Jae-Seon;Woo, Chul-Woong;Nam, Jeung-Hee
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.25-29
    • /
    • 2010
  • To evaluate the usefulness of newly designed percutaneous bone biopsy needle for pumpkin's specimen collection. We manufactured three types of biopsy needle with different internal processing which were made of 10 mm-diameter acrylic material. We made the conventional type (Ct) similar to the clinical type then compared the test group. The type a (Ta) made 1 cm-length internal processing from the distal, type b (Tb) made taper, and type c (Tc) made internal processing like spiral configuration. We performed 20 times biopsy to get an 10 mm length specimen from pumpkin's surface and evaluated the success rate of the biopsy, length of the specimen, and determine internal processing type of the most suitable biopsy needle (ANOVA test). Success rates of Ct, Ta, Tb, and Tc were 55%, 80%, 90%, and 100%, respectively. The lengths of the specimen of Ct, Ta, Tb, and Tc were $5.6{\pm}1.1\;mm$, $5.9{\pm}0.87\;mm$, $3.9{\pm}0.77\;mm$, and $9.4{\pm}0.54\;mm$, respectively. All groups were statistically significant (p < 0.05) except the group between Ct and Ta (p = 0.28). Newly designed bone biopsy needle seems to be useful for obtaining enough specimen. Tc may be more effective than other types.

Is the UU Stitch Really Alternative to Modified MA (Mason-Allen) Stitch for Rotator Cuff Repair? - Biomechanical Comparative Study of UU to Modified MA Stitch - (회전근 개 파열의 봉합에서 UU 봉합법은 변형된 MA(Mason-Allen) 봉합법을 대치할 수 있는가? - UU 봉합법과 변형된 MA 봉합법의 생역학적 비교-)

  • Friedman, Darren J;Ko, Sang-Hun;Park, Ki-Bong;Jun, Hyung-Min;Kim, Tae-Won;Lim, Hyun-Woo;Yum, Young-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • Purpose: In arthroscopic rotator cuff repairs there are generally weak link in tendon suture interface, arthroscopic rotator cuff repairs can have higher retear rates than open repairs. The purpose of this study was to compare the strength of UU (Ulsan University) suture than open modified MA (Mason-Allen) suture when suture anchored into bone. Materials and Methods: The human supraspinatus tendons were harvested from the shoulder of the cadaver and split in 2 times, producing four tendons per one shoulder, for a total of 24 specimens. Two suture configurations (UU, MA) were randomized and checked on each set of tendons. Specimens were cyclically loaded under force control between 5 and 30 N at 0.25 Hz for fifty cycles. Each specimen was loaded to failure under displacement control at 1 mm/sec. Cyclic elongation, peak to peak displacement, stiffness, ultimate tensile load, mode of failure were checked. Results: No significant difference was found between two suture configuration with respect to peak to peak displacement, cyclic elongation, and stiffness. With regard to ultimate failure load, there were no significant difference statistically between the UU suture and modified MA suture (109.4 N, 110.6 N). The most common mode of failure between both sutures was suture pull-out through the tendon. Conclusion: The UU suture and modified MA suture produced similar biomechanical properties.

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.