• Title/Summary/Keyword: k-band

Search Result 10,567, Processing Time 0.032 seconds

W-Band Permittivity Measurements Using a Free-Space Material Measurement Technique (자유공간 물질상수 측정법을 이용한 W-Band 유전율 측정)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Cho, Chihyun;Kim, Dae-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 2013
  • In this paper, a free-space material measurement technique is discussed in W-band(75~110 GHz). For the accurate measurement of S-parameters of an MUT(Material Under Test) in free space, a W-band quasi-optical free-space material measurement system, less affected by the measurement environments, is discussed, and GRL(Gated Reflect Line) method for calibrating the measurement system is described. Proposed technique is verified for 'Air' and measurement results for arystal plates of thickness 1.1 mm, 2 mm, 2.75 mm and 5 mm are also shown.

A Study on Fluorescence Imaging System Characteristics depending on Tilting of Band Pass Filter (대역통과필터의 기울임에 따른 형광 이미징 시스템 특성 분석 연구)

  • Kim, Taehoon;Cho, Sang Uk;Park, Chan Sik;Lee, Hak-Guen;Kim, Doo-In;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.2
    • /
    • pp.85-89
    • /
    • 2016
  • In this paper, we studied effects of tilting angle of band pass filter on the characteristics of fluorescence imaging system. Theoretical modeling showed that transmittance and filtering range are highly dependent on the tilting angle. Measurements on transmittance as a function of wavelength confirmed that changes in transmittance and the band filter range are in good agreement with theoretical prediction. Therefore, characteristics of band pass filter can be precisely tuned by altering tilting angle of band pass filter in order to enhance fluorescence signal in bio imaging system.

Experiences with Endoscopic Interventions for Variceal Bleeding in Children with Portal Hypertension: A Single Center Study

  • Kim, Seung Jin;Oh, Seak Hee;Jo, Jin Min;Kim, Kyung Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.4
    • /
    • pp.248-253
    • /
    • 2013
  • Purpose: The aim of this study was to compare the efficacy and safety of band ligation and injection sclerotherapy in the endoscopic treatment of children with variceal bleeding. Methods: The study population included 55 children, all of whom were treated at the time of endoscopic diagnosis of esophageal varices at Asan Medical Center, Seoul, Korea, between January 1994 and January 2011. The primary outcomes included initial success rates and duration of hemostasis after endoscopic management (band ligation vs. injectionsclerotherapy). Results: The mean age was $6.7{\pm}5.2$ years and the mean follow-up time was $5.4{\pm}3.7$ years. The most common cause of esophageal varices was biliary atresia. Of 55 children with acute variceal bleeding, 39 had band ligation and 16 had injection sclerotherapy. No differences between groups were observed in terms of the size, location, and presence of red color sign. The success rates of band ligation and sclerotherapy in the control of acute bleeding episodes were 89.7% and 87.5%. The mean duration of hemostasis after endoscopic intervention was $13.2{\pm}25.1$ months. After one year, 19 of 39 patients (48.7%) treated with band ligation and 7 of 16 patients (43.8%) with injection sclerotherapy had experienced rebleeding episodes. Complications after the procedures were observed in 10.3% and 18.8% of children treated with band ligation and injection sclerotherapy. Conclusion: The results of our current study suggest that band ligation and injection sclerotherapy are equally efficient treatments for the control of acute variceal bleeding and prevention of rebleeding.

Analysis of stealth design for naval vessels with wide band metamaterials (함정의 스텔스 설계를 위한 광대역 메타물질 적용 연구)

  • Hwang, Joon-Tae;Hong, Suk-Yoon;Kwon, Hyun-Wung;Song, Jee-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2206-2212
    • /
    • 2017
  • When it comes to naval surface warfare, the probability of detection is an important factor in survivability and the Radar Cross Section(RCS) is a major parameter. In this paper, the RCS reduction technology of the Radar Absorbing Material(RAM) method is carried out for the general frequency range for naval warfare. We set the analysis model with the simplified ship model and the wide band metamaterial which is high-tech radar absorbing materials is selected for the RAM method. The modeling of the wide band metamaterial composed of an MIK surface which has the wide band resonant properties and flexible substance and the electromagnetic absorptions and reflections of the wide band metamaterial has been simulated to explore the performance. Also, the wide band metamaterial is compared with the paint absorber to analyze RCS reduction in terms of RCS values.

Inflatable Lifejacket-Integrated Flexible Multiband Antenna (팽창식 구명조끼 장착용 유연한 다중대역 안테나)

  • Lim, Ji-Hun;Yang, Gyu-Sik;Jung, Sung-Hun;Park, Dong-Kook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.455-462
    • /
    • 2015
  • In this paper, we suggested multiband antenna that can be equipped on a inflatable life-jacket, operating VHF-DSC band(156 MHz), COSPAS-SARSAT band(406 MHz) and GPS band(1,575 MHz) for search and rescue survivors quickly. The GPS band antenna was implemented with a square ring-slot planar antenna, and the COSPAS-SARSAT and VHF-DSC band antenna were implemented meander type dipole antennas. In order to place the antenna on a life-jacket, we installed it on 0.2 mm thickness FR-4 substrate to obtain a flexibility. It appeared that the antenna has -14.6 dB, -30.9 dB, and -18 dB return loss in COSPAS-SARSAT, GPS, and VHF-DSC band, respectively. In addition, its gain has 0.83 dBi, 2.1 dBi in COSPAS-SARSAT and GPS band, respectively.

Effect of Resistance Band Exercise on Body Composition, Physical Fitness and Health Promoting Behavior in Nursing Students (탄성밴드운동이 간호대학생의 체성분, 체력과 건강증진행위에 미치는 효과)

  • Baek, Hee Chong;Lee, Suk Jeong;Shin, Gisoo;Lim, Eun Ju
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.2
    • /
    • pp.310-319
    • /
    • 2014
  • Purpose: The purpose of this study is to examine the effects of a resistance band training program on body composition, physical fitness, and health promotion behavior in nursing students. Method: This study has a one-group pretest-posttest design to examine the change in body composition, physical fitness, and health-promoting lifestyle profile after participation in the resistance band training program. Training consisted of hands-based exercises using an elastic resistance band for ten weeks. Participants performed the resistance band training two days per week with a sports trainer, and 30 minutes self-training three days per week. The participants were 21 freshmen in nursing. Results: Mean age of the participants was 20.9 years, and 61.9% were not satisfied with their body shape. After the training program, muscle mass, muscular endurance, and balance of the body were significantly improved. In health promoting lifestyle profile, categories of physical activity, health responsibility, and stress management showed a significant increase. Conclusion: Results of this study suggested that exercising with a resistance band improved body composition, physical fitness, and health promoting behavior in the nursing students. We propose that resistance band training should be suitable for those who have the environment with limitation of time and space.

Design of CPW-Fed Broadband Antenna Using the CSRR for WLAN Band Notched Characteristic (CSRR을 이용한 WLAN 대역 저지 특성 CPW 급전 광대역 안테나 설계)

  • Kim, Jang-Yeol;Lee, Seung-Woo;Kim, Nam;Oh, Byoung-Cheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.5
    • /
    • pp.528-537
    • /
    • 2011
  • In this paper, a broadband antenna of the CPW structure with a band-notched characteristic is presented. To obtain this characteristic, the complementary split ring resonator(CSRR) is inserted in the ground plane. In addition, the IEEE 802.11a WLAN band(5.15~5.825 GHz) appears in the band-notched characteristic. The proposed antenna dimension is $36{\times}60{\times}1.6\;mm^3$, and it is designed on the FR-4 substrate having a relative dielectric constant of 4.4. The designed antenna shows that the resonant frequency is 2.03~10.78 GHz below the return loss of -10 dB and a VSWR less than 2 was satisfied. As a result, the proposed CSRR has a band-notched characteristic in the range of 4.917~6.017 GHz which the center frequency is about 5.4 GHz band.

A Design of Miniaturized Built-in Penta-Band Chip Antenna for Mobile Handset (휴대 단말기 내장형 5중 대역 칩 안테나 설계)

  • Choi, Hyeng-Cheul;Kim, Hyung-Hoon;Park, Jong-Il;Kim, Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.3 s.118
    • /
    • pp.288-297
    • /
    • 2007
  • The novel internal monopole chip antenna of penta-band operation for GSM850/GSM900/DCS/USPCS/WCDMA bands for mobile phones is proposed. This antenna occupies a small volume $8\times3.2\times20mm^3$ and is suitable to be embedded in a mobile phone as an internal antenna. The minimization of the proposed antenna was realized by using spiral line structure and meander line structure on FR-4 of dielectric$(\varepsilon_r=4.4)$. The designed antenna has the wide-band operation in the upper band by overlapping high order resonances. The measured bandwidth of this antenna (VSWR>3) is 150MHz$(1,030\sim1,180\;MHz)$ in the lower band operation and 650 MHz$(1,760\sim2,410\;MHz)$ in higher band operation. The measured radiation efficiency within bandwidth(VSWR 3:1) is over 50 %. The antenna has been designed by a commercial software HFSS.

A Fundamental Genetic Study for Identifying Band 3 and CHS Genetic Diseases in Korean Cattle (Hanwoo) (한우 Band 3 및 CHS 유전병의 분자유전학적 기초연구)

  • Chung, Haeng-Jin;Yu, Seong-Lan;Sang, Byung-Chan;Lee, Jun-Heon
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.53-61
    • /
    • 2005
  • Many bovine genetic diseases are currently unidentified in Korea because of the relatively low monitoring systems in the livestock farms. The molecular detection system using PCR-RFLP of two genetic diseases, namely Band 3 (Erythrocyte Membrane Protein Band III) and CHS (Chediak-Higashi Syndrome), have been identified in Japan and used for screening large number of cattle whether each individual has the genetic disease or not. Using the 22 unrelated Korean cattle (Hanwoo) individuals, molecular detection system based on PCR-RFLP have been investigated, which can be distinguishable carriers for the genetic diseases. Even though we could not found the causative mutations for two genetic diseases, the PCR-RFLP techniques used in this study are very valuable for the screening the genetics diseases in Korean cattle, especially for the proven or candidate bulls.

  • PDF

Design of W-Band Diode Detector (W-Band 다이오드 검출기 설계)

  • Choi, Ji-Hoon;Cho, Young-Ho;Yun, Sang-Won;Rhee, Jin-Koo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.278-284
    • /
    • 2010
  • In this paper, a millimeter-wave detector using zero-bias schottky diode is designed and fabricated at W-band. It consists of LNA(Low Noise Amplifier) and detector module to improve sensitivity. LNA case with a highly stop-band characteristic is designed to prevent the oscillation by LNA MMIC chip. Diode detector of planar structure is fabricated for the easy connection with LNA module and zero bias Schottky diode is utilized. In practice, the fabricated diode detector have shown the detection voltage of 20~500 mV to the RF input power of -45~-20 dBm. The proposed W-band detector can be applicable to the passive millimeter image system.