Journal of Korean Tunnelling and Underground Space Association
/
v.24
no.6
/
pp.465-481
/
2022
Rock grouting is important to improve the waterproof efficiency and mechanical strength of rock medium with joint for utilizing the underground rock space such as tunnel. The grouting materials typically has been used the cement materials, which represent Bingham fluid model. This model can express the relationship of viscosity and yield strength. In addition, it is dependent with elapsed time. The grouting injection performance can be deteriorated with an increase of viscosity and yield strength in the grouting process if the time dependence is ignored. Therefore, in this study, the characteristics of viscosity and yield strength were investigated according to water-cement ratio and time dependence in the laboratory test. Numerical simulation was carried out to investigate the grouting performance according to the time dependence of characteristics in terms of the viscosity model. Given the results, the grouting injected distance and cumulative grout volume were significantly decreased when the time dependence of grouting material was considered. This study, considering the characteristics according to the time dependence of viscosity and yield strength, will be meaningful to the design of grouting injection in field applications.
Kim, Won-Seop;Lee, Jong-Hun;LeeSeo, Han-Seop;Park, Sang-Heup
Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.8
/
pp.133-138
/
2019
This study evaluated the tensile properties of SAPH440, a hot-rolled steel for automotive structural applications, based on GMAW lap welding, the welding current, the welding voltage, and the feed rate. Tensile tests were performed according to the joint parameters of the GMAW process, for which specimens were fabricated according to KS B ISO 9018 by lap welding. The bead appearance was observed in each condition, and the weldability was evaluated by the tensile test. Higher the welding current resulted in a deeper weld, but the tensile strength was not significantly different from when the parameter was fixed due to the fracture of the base material. When the current was higher than the voltage, as in the case of a welding current of 200 A and welding voltage of 17 V, a large amount of spatter is generated, the welding is unstable, and the welded part breaks. Higher the voltage resulted in the bead not causing defects in general, and it also affected the weldability. If the current and voltage were too low, the welding was not performed normally, and the tensile strength could not be measured. However, as the current increased, the increase of the voltage and the feed rate did not affect the tensile strength.
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.12
no.3
/
pp.242-250
/
2019
In this paper, we propose a method to predict the failure of industrial robot using Seq2Seq (Sequence to Sequence) model, which is a model for transforming time series data among Artificial Neural Network models. The proposed method uses the data of the joint current and angular value, which can be measured by the robot itself, without additional sensor for fault diagnosis. After preprocessing the measured data for the model to learn, the Seq2Seq model was trained to convert the current to angle. Abnormal degree for fault diagnosis uses RMSE (Root Mean Squared Error) during unit time between predicted angle and actual angle. The performance evaluation of the proposed method was performed using the test data measured under different conditions of normal and defective condition of the robot. When the Abnormal degree exceed the threshold, it was classified as a fault, and the accuracy of the fault diagnosis was 96.67% from the experiment. The proposed method has the merit that it can perform fault prediction without additional sensor, and it has been confirmed from the experiment that high diagnostic performance and efficiency are available without requiring deep expert knowledge of the robot.
Due to the constant changes of companies' global networks, the expansion of global e-commerce as well as the market-oriented global supply chain management, global enterprises are strategically selecting and entering into viable countries able to become global footholds. Therefore, this study aims to scrutinize the trend of changes in the global networks of Korean companies by analyzing the current overseas countries over the past decade. From the analysis, it has been found that there is a significant difference in the priorities of targeting countries among shipping, manufacturing and logistics companies. Logistics companies preferred to enter Germany first while they attached to a lower priority to Singapore. Manufacturing companies had a lower priority to advance to India, while they preferred to advance to Mexico; however, shipping companies were analyzed to prefer to enter the US. In addition, all of these companies identified the importance of securing volume and network by entering overseas markets to achieve economies of scale and scope and to maintain global competitiveness. Joint overseas expansion of manufacturers with shipping and logistics companies can be recommended to facilitate the entry and thus, enhance global competitiveness and service capabilities and also secure new growth engines.
Journal of the Korea institute for structural maintenance and inspection
/
v.23
no.1
/
pp.130-137
/
2019
Precast concrete (PC) structure is one of the type of the structures which is made in a facility prior to installing it to a construction field. The contact surfaces between two PC structures should be treated for obtaining enough binding force by inducing prestressing force. However, in the many cases, the contact surface causes the crack and leakage of water. These cracks and water leakage can cause the corrosion of the rebar, and the corrosion of the rebar can severely reduce the long-term durability. In this study, the SMA wire connector is suggested to solve the problem with the contact surfaces between two PC structures. The pull-out resistance of the suggested SMA wire connector is evaluated by conducting the tests to find the effect of the number of wires, shape of connector part, and shape memory effect. As a result of this study, the empirical formula is suggested to estimate the pull-out resistance related with the effects of the shape of the connector, shape memory effect, and the adhesive force. The validity between the estimated pull-out resistance and the measured value is confirmed.
Jung, Kyung Sik;Kim, Yun Young;Baek, Young Hwa;Jang, Eunsu
Journal of Physiology & Pathology in Korean Medicine
/
v.33
no.4
/
pp.226-232
/
2019
This study was aimed to reveal that the usual cold or heat state was associated with hypertension and could be a risk. We emailed educational personnel in D university to join this study and 182 subjects participated in from March to December in 2016. The usual cold or heat diagnosis was conducted by two experts who had over 10 years expertise. The blood pressure was measured from the subjected after 10 minute rest with Jawon medical device. The hypertension was diagnosed by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis was used in general characteristics, Pearson's Correlation Coefficient analysis was conducted in among continuous variables, and chi-square test was also used between hypertension and cold or heat group. Logistic regression was analyzed to generate the odds ratios (ORs) and 95% confidence interval (CI) for hypertension. The cold score was suggested to have negative association with Body mass Index (BMI, -.374, p<.001), systolic blood pressure (-.333, p<.001), and diastolic pressure (-.261, p<.001). The heat score was analyzed to have positive association with Body mass Index (.413, p<.001), systolic blood pressure (.249, p<.001), and diastolic pressure (.156, p<.001). The distribution of the cold group (35.1%) and non-cold group (64.9%) in hypertension was significantly different (p=0.18). The distribution of the heat group (62.2%) and non-heat group (37.8%) was significantly different (p=0.27). The usual cold was associated with decreased ORs (ORs 0.405, 95% CI=0.191-0.857), and usual heat was associated with increased ORs (ORs 2.327, 95% CI=1.108-4.888). However, after adjusting body mass index, sex, and smoking, the association was not significantly different. It is possible that usual cold or heat associate with hypertension. Further study is needed to show that usual heat may be a independent risk factor for hypertension through follow up design.
Journal of The Korean Society of Integrative Medicine
/
v.9
no.4
/
pp.283-289
/
2021
Purpose : The purpose of this study is to investigate the effect of mid frequency electrical stimulation during squat exercise on the muscle activity and muscle activity ratio of vastus medialis oblique and vastus lateralis, and to prepare scientific basic data for exercise intervention using mid frequency electrical stimulation. Methods : This study was conducted with students from University C located in Busan, and among a total of 123 subjects, 12 subjects who complained of knee joint dysfunction between 80 and 90 points using the Kujala patellofemoral score (KPS) were used. All subjects participated in the experiment for 3 days, and MVIC values were measured for normalization of muscle activity values on the first day. For the two days, participants participated in the experiment and performed squat exercise or squat exercise receiving mid-frequency electrical stimulation in random order. Measurements were taken in the squat position immediately after the squat exercise, and muscle activities of vastus medialis oblique and vastus lateralis were measured. The measured data were compared through the dependent t test, and the statistical significance level was set to .05. Results : According to the results of this study, in the case of applying mid-frequency electrical stimulation together in the ratio of vastus medialis oblique and vastus lateralis muscle activity during squat exercise, higher values were observed compared to the case of not applying mid-frequency electrical stimulation together, and statistically significant. Also, when mid-frequency electrical stimulation was applied to both vastus medialis oblique and vastus lateralis activities during the squat exercise, higher values were shown compared to the case where the mid-frequency electrical stimulation was not applied together, but there was no statistically significant difference. Conclusion : The results of this study reported that mid-frequency electrical stimulation provided to vastus medialis oblique increased the muscle activity ratio of vastus medialis oblique and vastus lateralis. Therefore, the improvement of coordination due to the enhancement of the activity of vastus medialis oblique through mid-frequency electrical stimulation will be more helpful in the treatment of patellofemoral pain syndrome patient. In addition, it is hoped that the electrical stimulation method applied to exercise will be widely used.
Purpose - The purpose of this study is to classify and analyze existing studies from various angles through systematic literature review of how human resources development has been researched in the domestic franchise business. These studies are intended to suggest the direction in which human resource development research should be conducted in the future in the franchise business. Research design, data, and methodology - This study is based on systematic literature review methodology. It has gone through the process of subject language setting, literature search routing, search term selection, literature selection, literature classification and literature analysis. The systematic literature review identified 59 peer-reviewed dissertations and scientific journal publications on the subject of HRD in Korea franchise business. Result - This study analyzed by research methods, research industries, research population and dependent variable using the systematic review process. The literature studied in the 2000s mainly led to research on education and training of franchise employees in beauty franchise business. In the literature studied since 2010, human resources development was mainly studied in the supervisor in the restaurant franchise business, and in the study of competence rather than education and training. According to the research methods, statistical methods were mostly relatively simple, such as t-test or one-way distribution analysis until the 2000s, and after 2010, in-depth and structural studies using multiple return analysis, structural method analysis, path analysis, multi-dimensional scale analysis, AHP, etc were conducted. When classified by study dependant, early research until the 2000s focused on the study of education and training, which is an independent variable, on the satisfaction of education programs, job satisfaction, and immersion. On the other hand, studies conducted since 2010 have produced more complex results using various medium variants, and those related to management performance and relationship performance have been mainly studied, rather than the satisfaction of the education itself. Conclusions - While the domestic franchise business is expanding in terms of quantity, such as the number of franchises and franchises, the development in terms of quality for the joint growth of franchises and franchisees is still lacking. In order for the franchisee to continue to grow with each other, the franchisee must identify and develop their current performance or expected capabilities through capacity modeling at various targets and levels.
Kang, Byung Woog;Baek, Dong Won;Chang, Eunhye;Kim, Hye Jin;Park, Su Yeon;Park, Jun Seok;Choi, Gyu Seog;Baek, Jin Ho;Kim, Jong Gwang
Journal of Yeungnam Medical Science
/
v.39
no.2
/
pp.141-149
/
2022
Background: The present study evaluated the clinical implications of adjuvant chemotherapy according to the mismatch repair (MMR) status and clinicopathologic features of patients with intermediate- and high-risk stage II colon cancer (CC). Methods: This study retrospectively reviewed 5,774 patients who were diagnosed with CC and underwent curative surgical resection at Kyungpook National University Chilgok Hospital. The patients were enrolled according to the following criteria: (1) pathologically diagnosed with primary CC; (2) stage II CC classified based on the 7th edition of the American Joint Committee on Cancer staging system; (3) intermediate- and high-risk features; and (4) available test results for MMR status. A total of 286 patients met these criteria and were included in the study. Results: Among the 286 patients, 54 (18.9%) were identified as microsatellite instability-high (MSI-H) or deficient MMR (dMMR). Although all the patients identified as MSI-H/dMMR showed better survival outcomes, T4 tumors and adjuvant chemotherapy were identified as independent prognostic factors for survival. For the intermediate-risk patients identified as MSI-low (MSI-L)/microsatellite stable (MSS) or proficient MMR (pMMR), adjuvant chemotherapy exhibited a significantly better disease-free survival (DFS) but had no impact on overall survival (OS). Oxaliplatin-containing regimens showed no association with DFS or OS. Adjuvant chemotherapy was not associated with DFS in intermediate-risk patients identified as MSI-H/dMMR. Conclusion: The current study found that the use of adjuvant chemotherapy was correlated with better DFS in MSI-L/MSS or pMMR intermediate-risk stage II CC patients.
Shin, Hyun Ho;Choi, Man Kwon;Cho, Myeong Whan;Kim, Jin Hyun;Seo, Tae Cheol;Lee, Choung Kuen;Kim, Seung Yu
Journal of Bio-Environment Control
/
v.31
no.4
/
pp.438-443
/
2022
In this study, the lateral loading test was performed to analyze structural performance of multi-span plastic greenhouse through full-scale experiment and numerical analysis. In order to analyze the lateral stiffness and stress, we installed 9 displacement sensors and 19 strain gauge sensors on the specimen, respectively, and load of l mm per minute was applied until the specimen failure. In the comparison between the full-scale experiment and the structural analysis results of a multi-span greenhouse with venlo-type roof according to bracing installation, there was a large difference in the lateral stiffness of the structure. By installing a brace system, the lateral stiffness measured near the side elevation of the specimen increased by up 44%. As the bracing joint used in the field did not secure sufficient rigidity, the external force could not be transmitted to the entire structure properly. Therefore, it is necessary to establish a bracing construction method and design standards in order for a greenhouse to which bracing applied to have sufficient performance.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.