• 제목/요약/키워드: joint depth

검색결과 438건 처리시간 0.043초

자동차용 강판의 겹치기 $CO_2$ 레이저 용접에서 발생되는 플라즈마 특성에 관한 연구 (Study on the characteristics of the plasma induced by lap-joint $CO_2$ laser welding of automotive steel sheets)

  • 남기중;박기영;이경돈
    • 한국레이저가공학회지
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 2002
  • In order to investigate the characteristics of the plasma induced by lap-joint CO$_2$ laser welding of automotive steel sheets, the effects of welding speed, shield gas flow rate, gap size, and laser beam defocus to plasma intensity emitted from keyhole have been investigated. The plasma light is measured by fiber and photodiode. Also, the plasma images were captured by the high speed digital camera in 1000frames/sec in order to correlate the plasma light signal with plasma pattern. From the results, it is observed that the difference of the plasma intensity for between the deep penetration and partial penetration exists from 1.2 to 2 times. The plasma light intensity decreased in case of the deep penetration Is observed due to the exhausting of the plasma gas under the sheet. On the other hand, under the conditions of the deep penetration, the plasma intensity is significantly increased by controling the conditions decreasing the penetration depth. It was specially founded that the effect of 0.3mm gap size at partial penetration condition is approximately similar to deep penetration in 0mm gap. It is concluded that the plasma intensity is able to evaluate the penetration depth in lap-joint welding and appears to offer the most straightforward correlation to the welding process.

  • PDF

5J32 알루미늄 합금의 마찰 점용접 (Spot Friction Welding of 5J32 Al alloy)

  • 이원배;이창용;연윤모;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 추계학술발표대회 개요집
    • /
    • pp.192-194
    • /
    • 2005
  • Joint strength of spot friction welded 5J32 Al alloy were investigated according to the tool shape and the tool penetration depth. General spot friction stir welding tool consists of a shoulder having bigger diameter and a threaded pin projected from the shoulder, which resulted in the generation of large up-lifting of upper plate around the weld nugget because of the deeper penetration and the severe stirring effect of threaded pin. Two kinds of welding tools without the threaded pin were used to avoid the distortion and improve the joint strength. One was a simple cylindrical shape and the other was cylindrical shape with small projection. Therefore, the process was named as spot friction welding comparing to spot friction stir welding because spot friction welding don't use a stirring effect. Using the cylindrical shape tool with small projection, the up-lifting of upper plate were avoided and joint strength were superior to that of the joint using simple cylindrical shape tool. At the 0.5mm of too penetration depth using cylindrical tool with small projection, nugget pull fracture mode can be observed and shear fracture mode were dominant at the rest conditions.

  • PDF

아연도금 강판과 고장력 강판 3겹 점용접물의 용접특성 평가 (Evaluation of Welding Characteristics on 3-lap Spot Joint of Zinc Coned Seel Sheet md High Seength Steel Sheet)

  • 권일현;김회현;백승세;양성모;유효선
    • 한국자동차공학회논문집
    • /
    • 제13권5호
    • /
    • pp.42-49
    • /
    • 2005
  • In general, multi-lap spot weld joints are frequently present in automobile. Most research, however, has been focused on the single-lap spot weld joints until now. In this paper, tensile-shear strength tests are performed to examine the weldability of 3-lap spot joint welded by using the high strength steel sheet and the zinc coated steel sheet. The indentation depth and nugget diameter are used to propose the optimum welding conditions. The weldability is affected by the welding current and welding time for 3-lap spot joint. Meanwhile the expulsions is round to decrease with the increase of electrode force. The optimum welding conditions are presented for 3-lap spot joints of high strength steel sheet and zinc coated steel sheet.

Cone-Beam Computed Tomographic Assessment of Temporomandibular Joint Morphology in Patients with Temporomandibular Joint Disc Displacement and in Healthy Subjects: A Pilot Study

  • Choi, Hang-Moon;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • 제41권2호
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the size and morphology of mandibular condyle and mandibular fossa between temporomandibular joint (TMJ) disc displacement (DD) patients and healthy subjects using cone-beam computed tomography (CBCT). Methods: Twenty healthy subjects and twenty TMJ DD patients participated in this study respectively. We made five measurements in mandibular condyle (medio-lateral dimension, antero-posterior dimension, condyle height, intercondylar distance and intercondylar angle) and two measurements in mandibular fossa (mandibular fossa depth and articular eminence angle) using CBCT image. Results: There was no difference between two groups in medio-lateral dimension. In case of antero-posterior dimension, average of healthy controls was larger than that of TMJ DD patients, but that was not significant statistically. There were no significant differences between two groups in condyle height. Comparing intercondylar distance and intercondylar angle between two groups, there was no significant difference between two groups. In comparison of mandibular fossa depth and articular eminence angle, there was no significant difference between two groups. Conclusions: We couldn't find any definite relationship between TMJ morphology and TMJ DD.

부정교합자의 하악과두 위치에 관한 단층방사선학적 연구 (A TOMOGRAPHIC STUDY OF CONDYLAR POSITION IN ASYMPTOMATIC SUBJECTS WITH MALOCCLUSION)

  • 김영주;고광준
    • 치과방사선
    • /
    • 제19권1호
    • /
    • pp.105-121
    • /
    • 1989
  • The author analysed tomograms and submento-vertex radiograms of 90 temporomandibular joints from 45 asymptomatic young adults. 15 had Angle class Ⅰ malocclusion, 15 classⅡ and 15 class Ⅲ. Corrected lateral tomograms were obtained in three condylar positions; centric occlusion, centric relation and 1 inch mouth opening. The condylar angulation, depth of cut, joint spaces were analysed in each radiogram. The obtained results were as follows; 1. The mean condylar angulation in Angle class Ⅰ, Ⅱ, Ⅲ group was 17.55±5.51° 13.33±8.85° 16.25±6.60° respectively, and there was no significant difference in each group. The mean condylar angulation of right side (16.62±7.23°) was larger than left side (14.80±7.33°). 2. The mean depth of cut in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.13±1.61㎝, 3.05±3.80㎝, 7.75±2.19㎝, respectively. Angle class Ⅰ and class Ⅱ group revealed significant difference in measurement (p<0.0l). 3. The mean height of articular fossa in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.67±3.06㎜, 9.61±2.57㎜, 8.93±2.83㎜, respectively. And the mean width of articular fossa was 19.90±2.80㎜, 19.48±3.83㎜, 20.36±4.82㎜, respectively. 4. The mean height and width of condylar head was 5.11±1.16㎜, 11.20±2.26㎜, respectively. 5. In centric occlusion, the superior joint space was the largest (3.42±1.42㎜), followed by anterior joint space (2.94±1.95㎜) and the posterior joint space (2.64±1.19㎜. In centric relation, the anterior joint space was the largest (3.86±2.17㎜), followed by the superior joint space (3.64±3.68㎜) and the posterior joint space (1.18±0.77㎜). 6. The displaced measurement from centric relation to centric occlusion was 1.10±1.04㎜ anteriorly and 0.24±0.97㎜ inferiorly. In 1 inch mouth opening state, the condylar head displaced posteroinferiorly (2.49±2.49㎜ posteriorly, 1.17±1.34㎜ inferiorly) from the apex of articular eminence. And Angle class Ⅰ and Ⅱ group, Angle class Ⅱ and Ⅲ group revealed significant difference in posterior measurement, respectively (p<0.01).

  • PDF

침수조건에 따른 저압 지중함의 감전 위험성 평가 (The Assesment of Electric Shock Rate of Low Voltage Joint-Box Based Submerged Condition)

  • 심건보;김경철;김한상;김종민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.265-270
    • /
    • 2007
  • The potential and step voltage distribution around low voltage joint-box cover were simulated with the variation of resistivity of water, depth of submerged water and point of leakage current. The potential distribution is very high gradient around low voltage joint-box, this condition is very dangerous states.

  • PDF

반복적인 격자 워핑 기법을 이용한 깊이 영상 초해상화 기술 (Iterative Deep Convolutional Grid Warping Network for Joint Depth Upsampling)

  • 김동신;양윤모;오병태
    • 방송공학회논문지
    • /
    • 제25권6호
    • /
    • pp.965-972
    • /
    • 2020
  • 깊이 영상은 물체와의 거리 정보를 가지고 있다. 이는 3D 정보를 구성하는데 중요한 역할을 한다. 보통 같은 시점에서 얻은 컬러 영상과 깊이 영상을 함께 사용한다. 그런데 하드웨어 기술의 한계로 인해 깊이 영상은 쌍을 이루는 컬러 영상에 비해 낮은 해상도를 갖는다. 따라서 일반적으로 깊이 영상을 사용할 때 영상의 해상도를 컬러 영상의 해상도에 맞게 업샘플링을 진행한 후 사용한다. 본 논문에서는 깊이 영상의 해상도를 높이기 위해 화소 값을 개선시키는 일반적인 방법이 아닌 화소의 위치를 이동시키는 방법을 제안한다. 제안하는 기법에서는 화소의 위치를 경계 주변에서 경계 중앙으로 이동시키며 이 과정을 여러 단계에 걸쳐 진행하여 블러된 영상을 복원한다. 실험 결과를 통해 제안하는 방법이 기존 방법들에 비해 정량적, 시각적 품질을 모두 개선시켰음을 알 수 있다.

심폐소생술 수행자의 엉덩관절 각도가 심폐소생술 결과에 미치는 영향 (Effect of Chest Compression Position Depending on the Rescuer's Hip Joint Angle During Basic CPR)

  • 이재민;윤형완
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.103-109
    • /
    • 2020
  • 이 연구는 기본심폐소생술 교과목을 이수한 응급구조과 학생을 대상으로 수행자 엉덩관절 각도에 따라 기본심폐소생술의 질이 향상되는지 알아보고자 하였다. 기본심폐소생술 중 엉덩관절 각도에 따른 기본심폐소생술 질(가슴압박 깊이, 완전한 이완, 압박속도 등)을 측정하기 위해 SimPad SkillReporter와 Resusci Anne® QCPR®을 이용하여 비교 분석하였고, 2015 AHA Guideline 따랐으며, 가슴압박과 인공호흡의 비율은 30:2로 5주기 시행하였다. 실험군과 대조군의 일반적인 자세에서는 엉덩관절 각도, 인공호흡정도, 가슴압박 깊이, 가슴압박 속도, 가슴압박 이완, 가슴압박 정확도, 가슴압박 중단시간(Hands off time), 가슴압박 적용시간 비율은 큰 차이를 보이지 않았다(p > 0.05). 엉덩관절 각도를 90도로 유지하는 기본심폐소생술은 유지하지 않았을 때와 큰 차이는 없었으나, 적정깊이와 100% 이완에서는 좋은 결과를 보여 주어 보다 더 나은 심폐소생술 질 향상을 기대할 수 있을 것이다.

남자 스포츠 에어로빅스 선수의 Depth Jump시 하지관절에 대한 운동역학적 분석-사례 연구 (The kinematic and kinetic analysis of lower extremities for male sports aerobic athletes during depth jumps - a case study)

  • 김윤지
    • 한국운동역학회지
    • /
    • 제15권1호
    • /
    • pp.259-274
    • /
    • 2005
  • The purpose of this study was to compare the kinematic and kinetic parameters of lower extremity joints between novice and experienced sports aerobic dancers during two heights of depth jumps. Four male dancers were participated in this study and they performed 40cm and 60cm height depth jump three times, respectively. Four ProReflex MCU cameras (100frame/sec) and a Kistler force plate (1000Hz) were used for data collection. The results indicated that the duration of contact phase of experienced group was shorter than that of novice group regardless of jump height. For minimum angle of hip, knee, and ankle joints, the novice group had tendency to decrease the angle but the experienced group had increased the joint angle with jump height. There was no difference of total ground reaction force between the groups but the reaction force had tendency to increase with jump height. Thus, this study implied that repetition of jump and landing may induce joint related injury and further study such as. EMG analysis of lower extremity can be needed to verify the relationship between injury and ground reaction force.

사용자의 동작인식 및 모사를 구현하는 로봇시스템 설계 (Robot System Design Capable of Motion Recognition and Tracking the Operator's Motion)

  • 최용욱;윤상현;김준식;안영석;김동환
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.605-612
    • /
    • 2015
  • Three dimensional (3D) position determination and motion recognition using a 3D depth sensor camera are applied to a developed penguin-shaped robot, and its validity and closeness are investigated. The robot is equipped with an Asus Xtion Pro Live as a 3D depth camera, and a sound module. Using the skeleton information from the motion recognition data extracted from the camera, the robot is controlled so as to follow the typical three mode-reactions formed by the operator's gestures. In this study, the extraction of skeleton joint information using the 3D depth camera is introduced, and the tracking performance of the operator's motions is explained.