• 제목/요약/키워드: jig

Search Result 683, Processing Time 0.026 seconds

MAXILLARY MOLAR DISTALIZATION AND PREMOLAR ALIGNMENT WITH A JONES JIG APPLIANCE: CASE REPORTS (Jones jig 장치를 이용한 상악 대구치 원심이동 및 소구치 배열의 증례 보고)

  • Jeon, Eun-Kyung;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.497-504
    • /
    • 2010
  • The treatment of Class II non-extraction cases, especially when premolar space is lost due to premature loss of the deciduous molars, usually requires distal movement of the maxillary molars. The Jones jig appliance is a non-compliant intraoral appliance and is effective for the distalization of the maxillary molars. It has unfavorable side-effects, however, so caution is needed to adjust the appliance and select appropriate cases. We reported four cases in which maxillary molar distalizations were concomitant with the alignment of palatally erupted premolars.

Manufacturing of molybdenum pin(CCFL) for electrode - convergency research on design and manufacturing of JIG and Fixture for molybdenum pin manufacturing and inspection (전극용 몰리브덴 핀 제조-몰리브덴 핀 제작 및 검사용 JIG and Fixture 설계 및 제작 융합연구)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.6
    • /
    • pp.197-201
    • /
    • 2020
  • The molybdenum cup and molybdenum pin, which are the main materials of the molybdenum electrode used for the LCD BLU CCFL electrode, did not been developed in Japan and all of them are imported and used from Japan, is giving a competitive burden. In this research, to develop the manufacturing technology of molybdenum pin used for CCFL electrode of LCD BLU, development of linear processing technology, development of molybdenum wire surface treatment technology, development of wire cutting technology, production of molybdenum pin, design and fabrication of JIG and Fixture for inspection, molybdenum pin prototyping and analysis, and development of 100% molybdenum pin inspection technology. In this paper, especially, research on design and manufacturing of JIG and Fixture for molybdenum pin manufacturing and inspection is treated.

Catching characteristics of northern shortfin squid by the experimental jig fishery in the Northwest Atlantic Ocean (NAFO area) (채낚기에 의한 북서대서양 캐나다 일렉스오징어 (Illex illecebrosus)의 어획특성)

  • Oh, Taeg-Yun;Kim, Jin-Young;Kim, Sun-Song;Kim, Young-Song;Yang, Won-Seok;Moon, Dae-Yeon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.42 no.4
    • /
    • pp.203-209
    • /
    • 2006
  • This paper described the experimental squid jigging fishery conducted by a commercial fishing vessel in the Northwest Atlantic Ocean from August to October 2005. Author carried out experimental jiggings of 65 times during 57 days by three type of jigs which were pick jig, soft jig and soft luminous jig. The total catch, effort/day and catches/line-day of northern shortfin squid (Illex illecebrosus) were 12,726kg, 35 auto jigging machine and 3.5kg, respectively. Higher CUPE was observed in September, August and October. Catch ratio of pick jig was higher by 57-86% than those of soft jig and soft luminous jig. Higher catch was recorded at the $42^{\circ}55'N,\;62^{\circ}10'W$ with surface temperature ranging $18-21^{\circ}C$. The range of the dorsal mantle length was from 13.5cm to 23.0cm with average 17.2cm for female and from 13.0cm to 20.0cm with average 17.0cm for male. Sex ratio showed 55.4% of female.

Basic Performance Evaluation of the Ecotoxicity Detection Device for Heavy Metals (중금속류 생태독성 검출장치의 기초성능 평가)

  • Kim, IlHo;Kim, Ji-Sung;Yoon, Young-Han;Ban, Hyo-Jin;Kim, Seok-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.828-834
    • /
    • 2012
  • The ecotoxicity detection device for preliminary test (Test jig) was manufactured to develop the biological early warning system using Vibrio fischeri. In this study, the ecotoxicity detection charateristics of the Test jig was investigated for 6 heavy metals (Cr, Zn, Pb, Cd, Cu and Hg). It was observed that relative luminescence unit (RLU) of Vibrio fischeri constantly decreased by the concentrations of the tested heavy metals. In contrast with other heavy metals, RLUs of Pb and Hg constantly decreased even at low concentrations. RLU of Hg drastically decreased when its concentration increased from 0.13 mg/L to 0.25 mg/L. $EC_{50}$ values of Cr, Zn, Pb and Cd gradually decreased with exposure time, whereas there was no significant change in $EC_{50}$ values of Cu and Hg with time. On the other hand, $EC_{50}$ values between the Test jig and Reference device were compared to evaluate the ecotoxicity detection performance of the Test jig. No big difference was found in $EC_{50}$ vlaues between the two devices, indicating that the Test jig could be applied as the ecotoxicity detection device for heavy metals.

Design of 2 Axles Fatigue Test JIG for the Materialization of Mixed Mode (Mode I+II) (혼합모드(Mode I+II)구현을 위한 2축 피로시험 JIG 설계)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Kim, Jam-Kyu;Choi, Myoung-Su;Kim, Woo-Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • Elements of a mechanical structure are getting from multi-axles stress. so fatigue characteristic experiment Shall execute in multi-axles stress state. it is very hard to apply according to forms of a testing machine and implementation. In this study, 2 axles fatigue testing machine did a design and Development. a new JIG developed to realize a mixed mode. a stress state in mixed mode of a specimen had each other comparison using the Finite element method to examine propriety of a new JIG.

  • PDF

Analysis of Strength and Displacement of Jig Body in Index Machine (Index Machine의 Jig Body 강도 및 변위해석)

  • 한근조;오세욱;김광영;안성찬;전형용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.24-30
    • /
    • 1998
  • Strength and displacement of jig body in index machine utilized for multiprocess machining such as drilling, boring and tapping, etc, at the same time were analyzed by the use of finite element analysis soft ware ANSYS 5.2A. The whole geometry was constructed by 4048 elements and 7016 nodes employing 8 node brick element. The analyses were carried out on five loading cases combining vertical and horizontal machining to simulate the case occurring large displacement and the one occurring small displacement one and provided following conclusions. (1) Jig body had sufficient strength because its safety factor was 6.95 even in the most severe loading case. (2) The largest displacement in Z direction was 549 m and that in radial direction was 43.7 m. (3) In order to reduce the displacement, vertical machining rather than horizontal or two or three processes should be adopted in the same station. (4) Alternate change of horizontal machining direction at consecutive stations can reduce the displace ment. (5) The dimension of the slider should be increased to reduce the displacement by the tolerance in the sliding part. (6) A bypass idle piston head needs to be installed to give a counterpart supporting load from opposite direction for a single horizontal machining case.

  • PDF

A study on wear damage of SKD11 steel material for a cutting mold jig (SKD11 절단금형치구용 소재의 마모손상에 관한 연구)

  • Nam, Ki-Woo;Kim, Cheol-Su;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.5-13
    • /
    • 2016
  • This study is on wear damage of the material for a molding machine that be used at finally cutting of metal beam made in roll forming process of vehicle bump beam process line. SKD11 steel was used with the material for cutting mold jig. In the cutting mold jig, Ti diffusion heat treatment after vacuum heat treatment was carried out for upgrade of surface hardness and anti-wear. Also, the heat treatments by various methods were performed to compare the wear damage degree against above the existing heat treatment. Wear loss and friction coefficient were obtained from wear test. And, micro Vickers hardness values were compared with damaged parts or not of cutting mold jig. Micro Vickers hardness value appeared higher at the undamaged part by Ti diffusion heat treatment. The micro Vickers hardness well followed a two-parameter Weibull probability distribution.

Optimum Design of Pin Jig to Control Ascent and Descent Offshore Structure Work Table for Weight Reduction (해양구조물 작업대 승하강 조절용 핀지그의 경량화를 위한 최적설계)

  • Hong D.K.;Woo B.C.;Choi S.C.;Park I.S.;Ahn C.W.;Han G.J.;Kang H.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1051-1054
    • /
    • 2005
  • On this study, we optimized minimizing the characteristic function for mixed result of the structural contact analysis and the buckling analysis according to the pin jig initial model's level change using mixed the table of orthogonal away and ANOM, Pin jig's weight is reduced up to 20 percent considering constraint conditions. Also we optimized reducing 20 percent weight of pin jig model using topology optimization.

  • PDF

Development of Drilling Jig by Practical and Adaptive Tooling System(Part 2)

  • Sim, Sung-Bo;Lee, Sung-Taeg
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.177-180
    • /
    • 2000
  • This is the continue paper as part 2 in this study. In order to prevent the production defects, the optimum design of product, jig and fixture and their making are very significant devision. especially the result of tryout and its analysis become the characteristics of this paper that nothing might be ever seen before such as this type of research method on all processes.

  • PDF