• 제목/요약/키워드: isotope dilution LC-MS/MS

검색결과 22건 처리시간 0.015초

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.