• Title/Summary/Keyword: isolation bearing

Search Result 246, Processing Time 0.033 seconds

Serviceability Evaluation of Sky Bridge With Isolation Device (면진장치 장착 스카이 브릿지의 사용성 평가)

  • Kim, Gee-Cheol;Kim, Hyun-Su;Kim, Su-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.71-77
    • /
    • 2017
  • In this study, the boundary non-linear analysis of the sky bridge subjected to walking load and running load is performed. The sky bridge is installed in the mid-story between two buildings and the walking load and running load induced by pedestrians are measured by load cell. LRB is modeled as a non-linear hysteresis model to accurately represent the behavior of LRB. For the serviceability evaluation of sky bridge, the acceleration responses of sky bridge are analyzed based on ISO 2631-2 and the velocity response are analyzed based on standards Bachmann &Amann. In serviceability evaluation of this sky bridge, the pedestrian can not perceive the vibration except for resonance running loads consequently. Therefore, it is concluded that this sky bridge haven't problem in the serviceability.

Testing of rubber bearings for the dynamic damper of seismic isolated buildings

  • Melkumyan, Mikayel;Hakobyan, Alexander
    • Smart Structures and Systems
    • /
    • v.2 no.4
    • /
    • pp.321-328
    • /
    • 2006
  • The paper describes the testing facilities and the methodology on testing of laminated rubber bearings envisaged for application in the system of Dynamic Damper (DD) of seismic isolated buildings, as well as the obtained results. For the first time in Armenia laminated rubber bearings were tested simultaneously under the action of horizontal shear force and vertical tension force. The test results have proven the possibility of using rubber bearings as elements subjected to tension due to action of the mass of DD. Also it was confirmed that the suggested structural concept of DD for reducing the displacements and shear forces of seismic isolation systems will have reliable behavior during the design level earthquakes.

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

Damping and Isolation Performance of Steel Structure (철골 구조물의 제진 및 면진성능)

  • Yun, Hyun-Do;Park, Wan-Shin;Han, Byung-Chan;Hwang, Sun-Kyoung;Lee, Giu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.221-230
    • /
    • 2004
  • In this paper, the dynamic response of a multi-story steel moment resisting frame equipped with viscoelastic dampers or lead rubber bearing type isolators subjected to seismic loads is investigated analytically. The objective of this study is to find the best location of viscoelastic dampers by the maximum stress method and maximum story drifts method from structure analysis. Also, a secondary objective of the study is to compare the member force, combined stress, and natural period of the structure retrofitted with viscoelastic dampers or lead rubber bearing type isolators to find effective vibration control method.

A Study on the Application of Friction Pendulum System in Main Control Room of Nuclear Power Plant (마찰진자를 이용한 면진장치의 원전 주 제어실 적용에 관한 연구)

  • Kim, Woo Bum;Lee, Kyung Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.407-417
    • /
    • 2005
  • An experimental and analytical study was performed to apply the friction pendulum system (FPS) to the main control room of a nuclear power plant. A friction pendulum bearing was fabricated, and the dynamic response of the bearing was evaluated. A partial model of a main control room attached to the FPS was tested on the shake table. The model consisted of a cabinet, a $3m\times3m$ access floor, and four friction pendulum bearings. The artificial time history based on the floor response spectrum of the main control room was used as the earthquake input signal in the test. Comparisons between the analytical study and the experimental study were conducted to verify the results and to extend the experimental study to the range of parameters that could not be experimentally studied.

Seismic base isolation for highway steel bridges using shape memory alloys (형상기억합금을 이용한 고속도로 강교량의 면진)

  • Choi, Eun Soo;Jeon, Jun Chang
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.145-153
    • /
    • 2004
  • Conventional lead-rubber bearings may be unstable in case of strong ground motions. To address this problem, this paper proposed a new concept of isolation device wherein shape memory alloy wires were incorporated in an elastomeric bearing. A three-span continuous steel bridge was used for seismic analyses to compare the performance of lead-rubber and proposed bearings. The proposed bearings showed almost the same performance as the lead-rubber bearings. In particular, the proposed bearings limited relative displacement effectively with strong ground motions and recovered its original undeformed shape.

The Study on the improvement of dynamic characteristics with multi-orifice in airspring (멀티 오리피스를 이용한 에어스프링 동특성 개선에 관한 연구)

  • 김인수;황성호;한문성;고철수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.97-103
    • /
    • 2002
  • Vibration isolation technology using an air spring and laminated rubber bearing is widely used because it has excellent vibration isolation characteristics. In the part of that, we usually make use of the self-damped air suing. It is occupied two chambers, restrictor, diaphragm and load plate. Two chambers contain compressed air and the volume of chambers and the area of load plate give a definition of stiffness and load. The restrictor and the volume ratio of two chambers give a definition of damping ratio. The conventional model of restrictor is made of one orifice and it causes turbulent flow in the orifice at the region of large deflection. The stillness of air suing is larger and the damping is lower in the region of large deflection. In the multi-orifice case, the stiffness is similar to air spring with one orifice but damping ratio is larger than conventional air spring. And damping ratio is smaller than conventional air suing in small deflection region. Deflection is small in the region of high frequency so small damping is better than large damping. As a result, we can reduce the storage stiffness of air suing in the wide region of deflection and increase the damping ratio in the region of large deflection. After this, we will try to and the relation of Reynolds Number and Flow Resistance then we are going to make another restrictor for air spring to improve damping ratio and stiffness.

  • PDF

Experimental Study on Seismic Performance of Base-Isolated Bridge (지진 격리된 교량의 내진성능에 대한 실험적 연구)

  • Chung, Woo-Jung;Yun, Chung-Bang;Kim, Nam-Sik;Seo, Ju-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.144-153
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrates that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation system using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminated rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil

  • Karabork, T.;Deneme, I.O.;Bilgehan, R.P.
    • Geomechanics and Engineering
    • /
    • v.7 no.1
    • /
    • pp.87-103
    • /
    • 2014
  • This study investigated the effect of soil-structure interaction (SSI) on the response of base-isolated buildings. Seismic isolation can significantly reduce the induced seismic loads on a relatively stiff building by introducing flexibility at its base and avoiding resonance with the predominant frequencies of common earthquakes. To provide a better understanding of the movement behavior of multi-story structures during earthquakes, this study analyzed the dynamic behavior of multi-story structures with high damping rubber bearing (HDRB) behavior base isolation systems that were built on soft soil. Various models were developed, both with and without consideration of SSI. Both the superstructure and soil were modeled linearly, but HDRB was modeled non-linearly. The behavior of the specified models under dynamic loads was analyzed using SAP2000 computer software. Erzincan, Marmara and Duzce Earthquakes were chosen as the ground motions. Following the analysis, the displacements, base shear forces, top story accelerations, base level accelerations, periods and maximum internal forces were compared in isolated and fixed-base structures with and without SSI. The results indicate that soil-structure interaction is an important factor (in terms of earthquakes) to consider in the selection of an appropriate isolator for base-isolated structures on soft soils.

Design and Fabrication of a Dual Polarized Load-bearing Microstrip Antenna (이중편파 하중 지지형 마이크로스트립 안테나 설계 및 제작)

  • 이라미;이정수;박위상;박현철;황운봉
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.125-135
    • /
    • 2001
  • A 8$\times$4 microstrip antenna array is designed at 5.3 GHz and its characteristics are investigated with respect to the application in dual polarized synthetic aperture radars. The design is focused on the achievement of a wide bandwidth, a high polarization purity, a low loss, a good isolation and some mechanical requirements suitable for the application. The antenna is fed by a -3 dB tapered feed network, and is composed of dual polarized SSFIP (Strip-Slot-Foam-Inverted Patch) elements with honeycomb and shielding plane. Simulation results for the antenna array are presented and compared with measurements. It is observed that the antenna shows a bandwidth of 80 MHz, a polarization isolation better than 20 dB, an isolation of 40 dB, and good mechanical characteristics.

  • PDF