• Title/Summary/Keyword: iso-performance line

Search Result 38, Processing Time 0.026 seconds

Assessment and Reliability Validation of Lane Departure Assistance System Based on DGPS-GIS Using Camera Vision (카메라영상에 의한 DGPS-GIS기반 차선변경 지원시스템의 평가 및 신뢰성 검증)

  • Moon, Sangchan;Lee, Soon-Geul;Kim, Minwoo;Joo, Dani
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This paper proposes a new assessment and reliability validation method of Lane Departure Assistance System based on DGPS-GIS by measuring lanes with camera vision. Assessment of lane departure is performed with yaw speed measurement and determination method for false alarm of ISO 17361 and performance validation is executed after generating departure warning boundary line by considering deviation error of LDAS using DGPS. Distance between the wheel and the lane is obtained through line abstraction using Hough transformation of the lane image with camera vision. Evaluation validation is obtained by comparing this value with the distance obtained with LDAS. The experimental result shows that the error of the extracted distance of the LDAS is within 5 cm. Also it proves performance of LDAS based on DGPS-GIS and assures effectiveness of the proposed validation method for system reliability using camera vision.

Real-Time Tool-Path Generation for 3-Axis CNC Machining of NURBS Surfaces (NURBS 곡면의 3축 CNC 가공을 위한 실시간 공구경로 생성)

  • Koo, Tae-Hoon;Jee, Sung-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1418-1425
    • /
    • 2003
  • In CAD systems, a surface to be machined is expressed by a series of curves, such as B-spline, Bezier and NURBS curves, which compose the surface and then in CAM systems the curves are divided into a large number of line or arc segments. These divided movement commands, however, cause many problems including their excessive size of NC data that makes almost impossible local adjustment or modification of the surface. To cope with those problems, the necessity of real-time curve or surface interpolators was embossed. This paper presents an efficient real-time tool-path generation method fur interpolation of NURBS surfaces in CNC machining. The proposed tool-path generation method is based on an improved iso-scallop strategy and can provide better precision than the existing methods. The proposed method is designed such that tool-path planning is easily managed in real-time. It proposed a new algorithm for regulation of a scallop height, which can efficiently generate tool-paths and can save machining time compared with the existing method. Through computer simulations, the performance of the proposed method is analyzed and compared with the existing method in terms of federate, total machining time and a degree of constraint on the scallop height.

Design and Implementation of A Distributed Information Integration System based on Metadata Registry (메타데이터 레지스트리 기반의 분산 정보 통합 시스템 설계 및 구현)

  • Kim, Jong-Hwan;Park, Hea-Sook;Moon, Chang-Joo;Baik, Doo-Kwon
    • The KIPS Transactions:PartD
    • /
    • v.10D no.2
    • /
    • pp.233-246
    • /
    • 2003
  • The mediator-based system integrates heterogeneous information systems with the flexible manner. But it does not give much attention on the query optimization issues, especially for the query reusing. The other thing is that it does not use standardized metadata for schema matching. To improve this two issues, we propose mediator-based Distributed Information Integration System (DIIS) which uses query caching regarding performance and uses ISO/IEC 11179 metadata registry in terms of standardization. The DIIS is designed to provide decision-making support, which logically integrates the distributed heterogeneous business information systems based on the Web environment. We designed the system in the aspect of three-layer expression formula architecture using the layered pattern to improve the system reusability and to facilitate the system maintenance. The functionality and flow of core components of three-layer architecture are expressed in terms of process line diagrams and assembly line diagrams of Eriksson Penker Extension Model (EPEM), a methodology of an extension of UML. For the implementation, Supply Chain Management (SCM) domain is used. And we used the Web-based environment for user interface. The DIIS supports functions of query caching and query reusability through Query Function Manager (QFM) and Query Function Repository (QFR) such that it enhances the query processing speed and query reusability by caching the frequently used queries and optimizing the query cost. The DIIS solves the diverse heterogeneity problems by mapping MetaData Registry (MDR) based on ISO/IEC 11179 and Schema Repository (SCR).

Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

Effects of Corn Distiller's Dried Grains with Solubles on Production Performance, Nutrient Digestibilities and Fecal Ammonia Emission in Laying Hens (옥수수주정박이 산란계의 생산성, 영양소이용율 및 분 암모니아 방출에 미치는 효과)

  • Shin, M.H.;Rew, H.J.;Lee, H.R.;Lee, S.K.;Lee, B.D.
    • Korean Journal of Agricultural Science
    • /
    • v.35 no.2
    • /
    • pp.137-145
    • /
    • 2008
  • A layer feeding trial was conducted to investigate the effects of high quality corn distiller's dried grains with solubles(DDGS) on laying performance and nutrient metabolizabilities. A total of 216 Hy-line Brown layers, 23-wk of age, were employed in a 10-wk feeding trial consisting of three dietary treatments(0%, 10%, and 20% DDGS), and six replicates per treatment. All experimental diets were prepared as iso-protein(17%) and iso-calorie(2,780 kcal/kg). At the end of the trial, the effect of DDGS on fecal ammonia emission was also estimated. The use of DDGS up to 20% in layer diets did not affect the feed intake, laying rate, egg weight, and feed conversion ratio(P>0.05). The DM metabolizability decreased significantly(P<0.05) by the DDGS supplementation(P<0.05). The NFE metabolizability decreased gradually as the level of DDGS increased(P<0.05). The fecal ammonia emission from DDGS-fed birds tended to decrease as the storage days extended. In conclusion, albeit DDGS has some unfavorable effects on DM and NFE metabolizabilities, it could be included in layer diets up to 20% level without any harmful effects on laying performance.

  • PDF

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Development of Automated Guidance Tracking Sensor System Based on Laser Distance Sensors

  • Kim, Joon-Yong;Kim, Hak-Jin;Shim, Sung-Bo;Park, Soo-Hyun;Kim, Jung-Hun;Kim, Young-Joo
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.319-327
    • /
    • 2016
  • Purpose: Automated guidance systems (AGSs) for mobile farm machinery have several advantages over manual operation in the crop production industry. Many researchers and companies have tried to develop such a system. However, it is not easy to evaluate the performance of an AGS because there is no established device used to evaluate it that complies with the ISO 12188 standard. The objective of this study was to develop a tracking sensor system using five laser distance measurement sensors. Methods: One sensor-for long-range distance measurement-was used to measure travel distance and velocity. The other four sensors-for mid-range distance measurement-were used to measure lateral deviation. Stationary, manual driving, and A-B line tests were conducted, and the results were compared with the real-time kinematic differential global positioning system (RTK-DGPS) signal used by the AGS. Results: For the stationary test, the average error of the tracking sensor system was 1.99 mm, and the average error of the RTK-DGPS was 15.19 mm. For the two types of driving tests, the data trends were similar. A comparison of the changes in lateral deviation showed that the data stability of the developed tracking system was better. Conclusions: Although the tracking system was not capable of measuring long travel distances under strong sunlight illumination because of the long-range sensor's limitations, this dilemma could be overcome using a higher-performance sensor.

Comparative Performance of Broilers Fed Diets Containing Processed Meals of BT, Parental Non-BT Line or Commercial Cotton Seeds

  • Elangovan, A.V.;Mandal, A.B.;Johri, T.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.1
    • /
    • pp.57-62
    • /
    • 2003
  • An effort was made to assess comparative production performance in broiler chickens fed diets containing solvent extracted cottonseed meal (CSM) processed from BT and Parental Non-BT lines. Processed meal of national check and commercial produce cottonseeds were also used for comparison. The free gossypol contents were 0.02, 0.02, 0.44 and 0.03% in meals of BT, Parental Non-BT, national check and commercial produce cottonseeds, respectively. Day-old broiler chicks (n=243) were divided to 27 groups of 9 each. Nine dietary treatments (iso-nitrogenous, 23% CP and iso-caloric, 2,800 kcal ME/kg) were formulated viz., D1 (control, soybean meal-SBM based), D2 and D3 (BT CSM at 10% of diet with and without additional iron), D4 and D5 (non-BT CSM with and without additional iron), D6 and D7 (national check CSM with or without additional iron), and D8 and D9 (commercial produce CSM with or without additional iron at 2 ppm for every 1 ppm of free gossypol, respectively). Each dietary treatment was offered to three replicated groups up to 6 weeks of age. At the end of 6 weeks of age, 10 birds were taken out randomly from each treatment and were sacrificed to study carcass traits, organs' yield and histo-pathological changes in vital organs. The broiler chickens received CSM processed from BT (D2, 1,753 g and D3, 1,638 g) and Parental Non-BT (D4, 1,653 g and D5, 1,687 g) with or without additional Fe grew at same rate as observed in soybean meal (solvent ext.) based diet (D1, 1,676 g). The feed intake and feed conversion efficiency (feed: gain) in these dietary treatments (BT, non-BT line based diets) also did not differ significantly (p>0.05) from control diet. Similar observation was also observed in dietary treatments (D8 and D9) containing solvent extracted cottonseed meal of commercial produce origin. However, a decrease (p<0.05) in body weight gain and feed intake was observed in D6 containing national check CSM with high gossypol content. Addition of Fe in the diet (D7) improved (p<0.05) feed intake and weight gain but not to the extent as observed in diets containing BT, parental non-BT, and commercial produce CSM or control. However, any type of CSM did not affect feed conversion efficiency when fed with or without additional iron. The carcass characteristics in terms of dressing percentage, liver weight and heart weight was not significantly (p>0.05) different between the treatments. The eviscerated yields emanated from diets containing either BT, non-BT or commercial produce were statistically similar to control. However, eviscerated yield of broilers fed national check CSM with or without iron supplementation was lower (p<0.05) than BT cotton with Fe supplementation and commercial produce CSM. The study envisaged that BT, parental non-BT and commercial produce solvent extracted cottonseed meal can be included at 10% in soybean meal based broiler diet replacing soybean meal and rice bran without additional iron.

A Study on the Reliability Improvement of RFID System (REID 시스템의 신뢰성 향상에 관한 연구)

  • Ham, Jung-Ki;Lee, Cheong-Jin;Kwon, Oh-Heung
    • Journal of Digital Contents Society
    • /
    • v.7 no.3
    • /
    • pp.169-174
    • /
    • 2006
  • In recent years, RFID is widely used in industrial applications including factory, material flow, logistics and defense areas. In this paper, The convolutional encoding and viterbi decoding is also implemented to improve the system performance. in an FPGA chip. The used convolution code is constraint length K=3 and rate R=1/2. The length of command frame and response frame is total of 48bits consisting of SOF 8 bits, command 16 bits, CRC 16 bit, and EOF 8 bits. And also the frame error rates are measured under the channel of line-of-sight and non line-of-sight, respectively. The performances are analyzed with FSK modulation only and FSK modulation added with convolutional encoding. These two measured results are compared with that of a RFID system with ASK modulation.

  • PDF