• 제목/요약/키워드: irradiation distance

검색결과 169건 처리시간 0.023초

YAG 레이저에 의한 SK5 표면경화 특성 (Surface Hardening Characteristics of SK5 Steel by Pulsed YAG LASER)

  • 강형식;문종현;전태옥;박홍식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.921-924
    • /
    • 1995
  • Case hardening behavior of carbon tool steel(SK5) was investigated after pulsed YAG laser irradiation. In the case od beam passes,martensite formed in the melt zone and in former pearlite regions of the austenitization zone exhibits vary high Vickers hardness values. The molten depth and width decrease as the beam power density increase. The influence of depth and width of color painted specimen was also investigated. The molten zone of the black painted specimen was the largest. The were loss of the black painted specimen was smaller than any other painted or raw material.

  • PDF

자외선조사(紫外線照射)에 의한 탁주효모(酵母)의 변이주육성(變異株育成)에 관한 연구(제 1 보) -변이주(變異株)의 선정(選定) 및 동정(同定)- (Studies on the Induction of Available Mutants of Takju Yeast by UV light Irradiation (Part 1) -On the Selection and Identification of the Mutants-)

  • 김찬조;오만진;김성렬
    • Applied Biological Chemistry
    • /
    • 제18권1호
    • /
    • pp.10-15
    • /
    • 1975
  • 충남북(忠南北)의 12개지역(個地域)에서 수집한 탁약주 술덧과 누룩에서 24주(株)의 효모(酵母)를 분리(分離)한 후(後) 발효력(醱酵力)이 강(强)한 2균주(菌株)를 모균(母菌)으로 선정(選定)하여 여러 조건하(條件下)에서 자외선(紫外線)을 조사(照射)시켜 그 효모(酵母)의 생존율(生存率)을 측정(測定)하고 또한 선정(選定)한 2모균주(母菌株)와 자외선조사(紫外線照射)로 얻은 3변이주(變異株)의 균학적(菌學的) 제성질(諸性質)을 조사(調査)하여 다음과 같은 결과(結果)를 얻었다. 1. 자외선(紫外線) 조사(照射)에 의(依)한 선정효모(選定酵母)의 생존율(生存率)은 다음과 같다. 조사거리(照射距離) 10(cm) 20 30 40 1%생존율(生存率) 1(sec) 20 $30{\sim}40$ $70{\sim}90$ 0.1%생존율(生存率) $15{\sim}20(sec)$ 40 $60{\sim}70$ $140{\sim}160$ 완전사멸(完全死滅) >25(sec) >60 >90 >220 2. 선정효모(選定酵母)에 자외선(紫外線)을 조사(照射)시켜 0.1% 생존율구(生存率區)에서 발육(發育)한 균주(菌株)들의 발효력(醱酵力)을 측정(測定)하여 발효력(醱酵力)이 모균(母菌)보다 약(約) 10% 강(强)한 $30{\sim}24$$40{\sim}27$의 2균주(菌株)와 모균(母菌)에서는 없든 강(强)한 생산능(生酸能)을 보인 $30{\sim}81$ 균주(菌洙)를 선정(選定)하였다. 3. 선정효모(選定酵母)를 Lodder의 분리법(分離法)으로 동정(同定)한 결과(結果) Saccharomyces cerevisiae로 동정(同定)되었으며 3변이주(變異株)들도 동정상(同定上)의 특성(特性)에는 그 모균(母菌)들과 다름이 없었다.

  • PDF

Philips LINAC 6 MV와 8 MV X선 소조사연에 대한 선량분포 측정 (Measurement of Dose Distribution in Small Beams of Philips 6 and 8 MVX Linear Accelerator)

  • 서태석;윤세철;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1991
  • 본 논문에서는 소조사면에 대한 X-선의 선량분포를 일반실험식으로 계산될 수 있도록 beam 측정 데이타를 종합 처리하는 방법에 대하여 기술하고 있다. Beam 데이타는 philips LINAC 6 MV, 8 MV X-ray에 대하여 측정 되었으며, 측정된 요소는 tissue maximum ratio (TMR), off-axis-ratio (OAH), 그리고 relative output factor (ROF)를 포함한다. 소조사면에 의한 방사선 치료를 위하여 isocenter에서 지름이 1 내지 3cm되도록 실린더 형태의 특수 collimator가 2 mm 간격으로 제작되었다. 본 측정을 위하여 다이오드 detector가 이용되었으며 Film 및 TLO 측정기로 측정된 값과 비교검토 되었다. 제한된 조사면으로 측정된 TMR, OAR data로부터 beam 데이타를 나타내는 실험식을 유도하였으며 이 실험식은 임의의 Set-UP조건에 따른 측정값을 예상할 수 있는 일반 실험식으로 확장되었고 측정된 TMR과 OAR 값들은 잘 일치되었다.

  • PDF

자궁경부암의 강내치료를 위한 선량측정 (Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer)

  • 김진기;김정수;김형진;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.13-18
    • /
    • 1995
  • 고선량의 RALS(Remote Afterloding Syetem)를 이용한 근접조사에서 선원의 위치에 따라 선량분포는 거리제곱의 반비례 형태로 변화되므로, 관심점의 흡수선량은 선원의 교정에 의해 크게 영향을 받는다. 자궁경부암 강내치료시 정확한 흡수선량을 결정하고자 선원을 교정하고, 선원의 위치에 따른 선량분포도에 의한 계산값과 반도체 검출기와 전리함을 이용한 설측값과 차이를 비교하고 보정 방법을 논의 하였다. Bulcher-RALS를 이용하여 치료에 사용된 선원의 교정은 공기커마와 사각형 아크랄 팬톰을 이용하여 r 인자에 의한 거리 역자승법칙으로 계산하였고, Co-60 선원의 8cm 거리에서 검교정된 측정기를 이용한 선량율을 비교치로 이용하였다. 선량측정치의 재현성은 팬톰내에서 0.3~1.1% 였으며, 측정치의 분포는 Bulcher-RALS 선량분포도에 의한 계산값과 팬톰측정치의 비교에서 -3~17%, 강내치료를 받은 18 명의 환자를 대상으로한 직장내 흡수선량에서 체내 실측값과 차이는 환자와 선원의 위치에 따라 -6~+21%로 측정값이 평균 6.3% 높게 나타났다.

  • PDF

방사선 저항세균 Micrococcus roseus의 광펄스 살균 효과 (Effect of Sterilization by Intense Pulsed Light on Radiation-resistant Bacterium, Micrococcus roseus)

  • 김보라;김애진;신정규
    • 한국식품과학회지
    • /
    • 제45권2호
    • /
    • pp.248-251
    • /
    • 2013
  • 김에 존재하는 M. roseus는 비병원성 세균이나 사람이 면역력이 떨어지게되면 질병을 일으킬 수 있는 균주로서 열처리를 통해서도 쉽게 사멸되지 않고 특히 10 kGy의 감마선 조사에서도 1 log, 40 kGy의 조사선량에서 1 log CFU/mL 이상의 생존율을 나타내는 방사선 저항 세균이다. 이러한 방사선 저항 세균인 M. roseus를 광펄스 살균을 통해 살균 가능성을 알아보았다. M. roseus는 빛의 세기가 증가함에 따라 사멸율이 증가하는 경향을 나타냈으며, 1,000 V의 빛의 세기에서 3분 처리 후에 6.4 log의 감소효과를 보였고 tailing 현상을 보이지 않았다. 빛의 세기와 처리시간을 같이 한 조건에서는 단위 시간동안 펄스 수가 높을수록 살균율이 높아졌으며, 10 pps에서는 2분의 처리로 모든 균이 사멸하였다. 또한 광원과 시료사이의 거리는 가까울수록 사멸율이 증가하는 경향을 보였다. 이러한 연구 결과로 볼 때 광펄스 살균이 향후 김의 위생적 처리의 방법의 하나로 가능성이 있을 것으로 예측된다.

고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰 (A Study on the dosimetry in boundary of shielding block in high energy irradiation)

  • 김명세;김성규;신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제7권2호
    • /
    • pp.115-120
    • /
    • 1990
  • 18MeV 선형가속기와 코발트 원격치료기를 사용하여 방사선 조사면적 내에 차폐물이 있는 경우, 차폐물에 의한 산란선이 선량분포에 미치는 영향에 관하여 고찰하여 다음과 같은 결과를 얻었다. 1. 차폐물이 이루는 각이 예각일수록 산란선의 효과는 더 크게 나타났다. 2. 차폐물의 넓이가 좁을수록 산란선의 효과는 더 크게 나타났다. 3. 조사면적에 따른 출력특성은 선형적이지만, 차폐물에 의한 출력특성은 조사면적에 대하여 선형가속기는 거의 무관하게 나타났으며, 코발트 원격치료기는 기울기가 적은 선형성을 나타내었다.

  • PDF

치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구 (THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY)

  • 박태원
    • 치과방사선
    • /
    • 제9권1호
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

Laser Hyperthermia에서 조건변동에 따른 병소변화 (Laserthermia Induced Histological Changes in Different Thermal Condition)

  • 김상우;이경엽;김성호;배장호;김오룡;최병연;조수호;신현진;이준하
    • Journal of Yeungnam Medical Science
    • /
    • 제12권2호
    • /
    • pp.331-338
    • /
    • 1995
  • 18마리 가토의 양측 대뇌반구에 laserthemia후 발생하는 조직학적 변화와 온도변화에 따른 변성의 측정결과는 아래와 같다. 주된 조직학적 변화는 chromatin 응축, myelin 응축, 적혈구 탈색, nuclear waving, nuclear palisading과 세포괴사 등이었다. 온도 변화에 따른 변성의 정도는 $44.5^{\circ}C$이상에서 현저하였으며, 비교치 설명후 그 범위도 약 5배(1.25 mm)정도의 변화를 보였다. Laserthermia에 의한 세포괴사는 $47.5^{\circ}C$이상에서부터 현저하게 보였다. 뇌의 심부병소의 정위적 수술시 온도설정 및 병소치료 범위의 예상이 가능하다.

  • PDF

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Initial Dosimetry of a Prototype Ultra-High Dose Rate Electron-Beam Irradiator for FLASH RT Preclinical Studies

  • Hyun Kim;Heuijin Lim;Sang Koo Kang;Sang Jin Lee;Tae Woo Kang;Seung Wook Kim;Wung-Hoa Park;Manwoo Lee;Kyoung Won Jang;Dong Hyeok Jeong
    • 한국의학물리학회지:의학물리
    • /
    • 제34권3호
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: FLASH radiotherapy (RT) using ultra-high dose rate (>40 Gy/s) radiation is being studied worldwide. However, experimental studies such as preclinical studies using small animals are difficult to perform due to the limited availability of irradiation devices and methods for generating a FLASH beam. In this paper, we report the initial dosimetry results of a prototype electron linear accelerator (LINAC)-based irradiation system to perform ultra-high dose rate (UHDR) preclinical experiments. Methods: The present study used the prototype electron LINAC developed by the Research Center of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Korea. We investigated the beam current dependence of the depth dose to determine the optimal beam current for preclinical experiments. The dose rate in the UHDR region was measured by film dosimetry. Results: Depth dose measurements showed that the optimal beam current for preclinical experiments was approximately 33 mA, corresponding to a mean energy of 4.4 MeV. Additionally, the average dose rates of 80.4 Gy/s and 162.0 Gy/s at a source-to-phantom surface distance of 30 cm were obtained at pulse repetition frequencies of 100 Hz and 200 Hz, respectively. The dose per pulse and instantaneous dose rate were estimated to be approximately 0.80 Gy and 3.8×105 Gy/s, respectively. Conclusions: Film dosimetry verified the appropriate dose rates to perform FLASH RT preclinical studies using the developed electron-beam irradiator. However, further research on the development of innovative beam monitoring systems and stabilization of the accelerator beam is required.