• Title/Summary/Keyword: ionomers

Search Result 66, Processing Time 0.032 seconds

A STUDY ON THE COLOR STABILITY OF RESIN MODIFIED GLASS IONOMERS (레진 강화형 글라스아이오노머의 색 안정성에 관한 연구)

  • Koo, Dae-Hoi;Lee, Yong-Keun;Son, Ho-Hyun;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.358-373
    • /
    • 1997
  • Resin modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strength of conventional glass ionomers and to maintain their clinical advantages. The purpose of this study was to evaluate the color stability of four resin modified glass ionomers(Fuji II LC, Vitremer, Dyract and VariGlass), one resin composite material(Z-100), and one conventional glass ionomer(GC Fuji II) under several conditions. These conditions were as follows: 1) before curing, 2) after curing, 3) after polishing, 4) after 500 thermocycling, 5) after 1,000 thermocycling, 6) after 1,500 thermocycling and 7) after 2,000 thermocycling. Three specimens of each material/shade combination were made. Materials were condensed into metal mold with a diameter of 10 mm and a thickness of 2.0 mm, and were pressed between glass plates. The material was polymerized using a light polymerizing unit(Visilux II, 3M, USA). After removal of excess, the surface was polished sequentially on wet sandpapers. A reflection spectrophotometer(Model TC-6FX, Tokyo Denshoku Co., Japan) was used to determine CIELAB coordinates($L^*,a^*$ and $b^*$) of each specimen. CIE standard illumination C was used as the light source. The results were as follows : 1. In comparing different shades of same material, CIELAB color difference(${\Delta}E^*$) value was not significantly different from each other(p>0.05). 2. CIELAB color difference(${\Delta}E^*$) values between after-curing and after-polishing were ranged from 5.53 to 27.08. These values were higher than those of other condition combinations. 3. CIELAB color difference(${\Delta}E^*$) values between before-thermocycling and after-thermocycling were ranged from 1.40 to 7.81. Despite the number of thermocycling increased, CIELAB color difference(${\Delta}E^*$) value was low. 4. The color stability of resin modified glass ionomers was more stable than that of conventional glass ionomers but less stable than that of Z100.

  • PDF

BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS (레진강화형 글라스아이오노머의 2 축 굽힘강도)

  • Lee, Yong-Keun;Im, Mi-Kyung;Koo, Dae-Hoi;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF

A COMPARISON OF THE SETTING CHARACTERISTICS BETWEEN RESIN-MODIFIED GLASS-IONOMERS AND COMPOMERS (Resin-Modified Glass-Ionomer와 Compomer의 경화 반응 특성의 비교에 관한 연구)

  • Ko, Yong-Joon;Yoo, Hyeon-Mee;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.123-132
    • /
    • 2000
  • To overcome problems of conventional glass ionomers, resin components have been added to glass ionomers. On a continuum between glass ionomers and composites are a variety of blends, employing different proportions of acid-base and free radical reactions to bring about cure. Popular groups defined between the ends are resin-modified glass-ionomers(RMGIs), polyacid-modified composite resins(Compomers) and ionomer modified resins. These groups show different clinical properties, and in selecting these materials for a restoration, one should sufficiently understand these different setting properties. In this study, some difference in the setting characteristics of different groups of hybrid ionomers were examined. Two RMGIs (Fuji2 LC,GC / Vitremer, 3M), three Compomers (Dyract AP, Dentsply / F2000, 3M / Elan, Kerr) were involved in this study. The identification of the setting characteristics of different groups was achieved by a two-stage study. First, thermal analysis was performed by a differential scanning calorimeter, and then the hardness of each group at different depth and time were measured by a micro-hardness tester. Thermal analysis was performed to identify the inorganic filler content and to record the heat change during setting process. The setting process was progressed for each material by chemical set mode and light-cured mode. In the hardness test, samples of materials were prepared with a 6mm-diameter metal ring, and the hardness was measured at the top, and 1mm, 2.5mm, 4mm below at just after a 40 second-cure, and after 10 minutes, 24 hours, and 7 days. Statistical analysis was performed by Mann-Whitney rank sum test to assess significant differences between set modes and types of materials, and by ANOVA and T-test to evaluate the statistical meanings of data at different times and depths of each materials. Followings are findings and conclusions derived from this study. Thermal analysis; 1. Compomers show no evidence of chemical setting while RMGIs exhibit heat output during the process of chemical setting. 2. Heat of cure of RMGIs exceed Compomers. 3. The net heat output of RMGIs through light-cured mode is higher than through chemically set mode. Hardness test; 1. Initial hardness of RMGIs immediately after light cure is relatively low, but the hardness increases as time goes by. On the contrary, Comomers do not show evident increase of the hardness following time. 2. Compomers show a marked decrease of setting degree as the depth of the material increases. In RMGIs, the setting degree at different depths does not significantly differ.

  • PDF

Perfluorinated Sulfonic Acid Ionomer-PTFE Pore-filling Membranes for Polymer Electrolyte Membrane Fuel Cells (고분자전해질연료전지용 과불소계 술폰화 이오노머-PTFE 강화막)

  • Kang, Seong Eun;Lee, Chang Hyun
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.171-179
    • /
    • 2015
  • Perfluorinated sulfonic acid ionomers (PFSAs) have been widely as solid electrolyte materials for polymer electrolyte membrane fuel cells, since they exhibit excellent chemical durability under their harsh application conditions as well as good proton conductivity. Even PFSA materials, however, suffer from physical failures associated with repeated membrane swelling and deswelling, resulting in fairly reduced electrochemical lifetime. In this study, pore-filling membranes are prepared by impregnating a Nafion ionomer into the pore of a porous PTFE support film and their fundamental characteristics are evaluated. The developed pore-filling membranes exhibit extremely high proton conductivity of about $0.5S\;cm^{-1}@90^{\circ}C$ in liquid water.

Sulfonated Polystyrene Ionomers Containing 4-Aminobenzoic Acid Studied by a Small-Angle X-Ray Scattering Technique

  • Song, Ju-Myung;Hong, Min-Chul;Kim, Joon-Seop;Jikang Yoo;Yu, Jeong-A;Kim, Whangi
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.304-310
    • /
    • 2002
  • In a recent study by the same authors using a DMTA (Dynamic Mechanical Thermal Analyzer), it was found that the 4-aminobenzoic arid (ABA) molecules acted as either a neutralizing agent, or a plasticizer, or a filler, depending on the order of mixing of poly(styrene-co-styrenesulfonic acid) (PSSA), ABA, and NaOH. Subsequent to that study, we here pursued the same topic, i.e., the effect of the addition of CsOH (instead of NaOH) and ABA on the morphology of PSSA, but this time, by using a small-angle X-ray scattering (SAXS) technique. In line with the previous results, the present study with the SAXS technique verified that the order of mixing has a significant effect on the morphology of ionomers. In addition, with the SAXS data and the density values of the ionomers, we attempted to calculate both the number of sulfonate ionic groups per multiplet and the size of the multiplet of the ionomer.

Relationship between Structure and Properties of UV-Curable Polyurethane Acrylate Ionomers

  • 김태우;김한도
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1996.10a
    • /
    • pp.468-472
    • /
    • 1996
  • A series of UV-curable polyurethane acrylate ionomer were synthesized from isophorone diisocyanate(IPDI), poly(tetramethylene ether glycol)(PTMG), 2,2-bis(hydroxymethyl)propionic acid (CMPA), triethylamine(TEA), 2-hydroxy ethyl acrylate (HEA), and dibutyl tin dilaurate (DBT) as a catalyst. 2,2-dimethoxy-2-phenyl acetophenone(DMPAP) was used as a photoinitiator. The films of UV-cured polyurethane acylate ionomer were prepared by casting the formulated materials onto a glass plate at room temperature and cured using a medium pressure mercury lamp (80 W/cm, max = 365nm). Effects of DMPA content, molecular weight of PTMG and degree of neutralization on the properties were invesigated. It is found that the storage modulus increased with increasing DMPA content. The glass transition temperature of sample A shifted to higher temperature as the content of DMPA was increased. Tensile modulus also increased with increasing DMPA content. Modulus and Tg decreased with increasing molecular weight of PTMG form 650 to 2000. With increasing the degree of nutralizaion, ionomers exhibited improved modulu.

  • PDF

195Pt NMR Study of the Influence of Nation Ionomer on the Enhanced Local Density of States at the Surface of Carbon-Supported pt Catalysts

  • Han, Kee-Sung;Lee, Moo-Hee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.135-142
    • /
    • 2009
  • $^{195}Pt$ NMR measurements were performed to deduce the variation of local density of states at the Fermi energy ($E_F$-LDOS) at the surface of carbonsupported Pt catalysts due to the addition of $Nafion^{(R)}$ ionomer in the metalelectrode-assembly for fuel cells. The results showed that the EF-LDOS at the surface of Pt particles was enhanced by the addition of $Nafion^{(R)}$ ionomers whereas it was uninfluenced in the inner (bulk) part of the Pt particles. This suggests that the effects of ionomers on the electronic states of the Pt particle surface are related to the electrochemical activity of the catalysts.

Plasticization in Unclustered Poly(methyl methacrylate) Ionomers

  • 김준섭;김희석;Adi Eisenberg
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.625-628
    • /
    • 1998
  • The dynamic mechanical properties of the unclustered cesium neutralized poly(methyl methacrylate-co-methacrylic acid) ionomers plasticized with three different plasticizers of low molecular weight were investigated. It was found that the effectiveness of the plasticization followed the order: glycerol (Gly) 4-decylaniline (4DA) >dioctyl phthalate (DOP). For the ionomer plasticized with Gly, the only effect was a significant decrease in the Tg. Thus it is concluded that the polar plasticizer not only increases the mobility of the ionomer but also dissolves the ionic groups. In the case of the 4DA-plasticized ionomer, both a drastic decrease in the Tg and the appearance of a second glass transition were observed. Therefore, it is suggested that the nonpolar 4DA molecules partition evenly in the poly(methyl methacrylate) matrix and cluster phases via hydrogen bonding between the aniline group of the plasticizer and the carbonyl groups of the ionomer. As a result, the Tg is lowered, multiplets can form, and the material behaves like a clustered ionomer.