• Title/Summary/Keyword: ion-exchange resin

Search Result 368, Processing Time 0.029 seconds

A Study on Process Performances of Continuous Electrodeionization with a Bipolar Membrane for Water Softening and Electric Regeneration (바이폴라막을 이용한 연수용 전기탈이온의 공정 효율 및 전기적 재생에 관한 연구)

  • Moon, Seung-Hyeon;Hong, Min-Kyoung;Han, Sang-Don;Lee, Hong-Joo
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.210-218
    • /
    • 2007
  • CEDI-BPM(Continuous Electrodeionization-Bipolar Membrane) has advantages due to high ion permselectivity through ion exchange membranes and the production of $H^+$ and $OH^-$ ions on the bipolar membrane surfaces for regeneration of ion exchange resin during electrodeionization operation. In this study, hardness materials were removed by the CEDI-BPM without scale formation and the ion exchange resins were electrically regenerated during the operation. The adsorption characteristic of ion exchange resin surface, the influence of flow rate on the hardness removal and electric regeneration were investigated in the study. The removal efficiency of Ca was higher than that of Mg in the CEDI-BPM, which was related to the high adsorption capacity of Ca on the cation exchange resin. With increasing flow rate, the flux of Ca and Mg was enhanced by the permselectivity of a cation exchange membrane. In the electric regeneration of CEDI-BPM, it was shown that the regeneration efficiency was higher with a lower regeneration potential applied between cathode and anode.

The design parameter evaluation of ion exchange process for ultra pure water production (초순수 생산을 위한 이온교환공정 설계특성 평가)

  • Park, Se-Chool;Kwon, Boung-Su;Lee, Kyung-Hyuk;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • In this study, cation and anion exchange process for performance evaluation was conducted. A pilot plant for the ultrpure water production was installed with the capacity of $25m^3/d$. The various production rate and regeneration of ion exchange rate were tested to investigate the design parameters. The test resulst was applied to calculate the operating costs. Changing the flow rate of the ion exchange capacity of the reproduction reviewed the cation exchange process as opposed to the design value is 120 to 164% efficiency, whereas both anion exchange process is 82 to 124% efficiency, respectively. This results can be applied for more large scale plant if the scale up parameters are consdiered. The ion exchange capacity of the application in accordance with the design value characteristic upon application equipment is expected to be needed. In this study, the performance of cation and anion exchange resin process was evaluated with pilot plant($25m^3/d$). The ion exchange capacity along with space velocity and regeneration volume was evaluated. In results, the operation results was compared with design parameters.

Determination of Taurine in Preparations by Amino Acid Autoanalyzer (아미노산 분석기에 의한 제제중 Taurine의 분리 정량에 관한 연구)

  • 박만기;한달수
    • YAKHAK HOEJI
    • /
    • v.28 no.1
    • /
    • pp.21-23
    • /
    • 1984
  • High performance amino acid analyzing method has been developed for the routine analysis of taurine in preparations. Ion-exchange resin #2619 Hitachi Custom Ion-Exchange Resin, $2.6(I.D.){\times}150$(length)mm was used as column, buffer I, pH 3.3 as mobile phase. The retention time of taurine was 7 minutes. Calibration curve by peak height for standard taurine was linear from 2.5ppm to 25ppm. The reproducibility showed relative standard deviation $\pm$1.9% when analyzed 10 times for standard solution. The samples could be continuously analyzed without regenerating the resin between samples. Five samples were applied to column every 12 min. and then the resin was regenerated for 30 min. during one analyzing cycle time, 90 min. The automatic amino acid analyzer has made it possible to assay multiple samples in a relatively short period of time using the analytical magnetic program card. The high sensitivity and specificity of the analytical column of the automatic amino acid analyzer permits the routine analysis of taurine in preparations.

  • PDF

Enrichment of Lithium Isotope by an Ion Exchange Resin Containing Azacrown Ether (아자크라운 에터를 포함한 이온교환수지에 의한 리튬 동위원소의 농축)

  • Kim, Dong Won;Chung, Yongsoon;Choi, Ki Young;Lee, Yong-Ill;Jeong, Young Kyu;Jang, Young Hun
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.403-407
    • /
    • 1997
  • Separation factor for $^6Li$ and $^7Li$ have been determined using ion exchange resin having 1,7,13-trioxa-4,10,16-triazacyclooctadecane($N_3O_3$) as an anchor group. The lighter isotope, $^6Li$ is concentrated in the solution phase, while the heavior isotope, $^7Li$ is enriched in the resin phase. By Ccolumnl chromatography[0.9cm(I.D)${\times}$20cm(height)] using 2.0M ammonium chloride solution as an eluent, single separation factor, ${\alpha}$, 1.009. i.e.$(^7Li/^6Li)_{resin}$/$(^7Li/^6Li)_{solution}$ was obtained by the Glueckauf theory from the elution curve and isotope ratios.

  • PDF

Recovery of High Purity Tin from Waste Solution of the Tin Plating by Ion-exchange and Cyclone-electrowinning (주석도금폐액으로부터 이온교환 및 사이클론 전해채취를 이용한 고순도 주석의 회수)

  • Kang, Yong-Ho;Shin, Gi-Wung;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.25 no.4
    • /
    • pp.42-48
    • /
    • 2016
  • A research for the recovery of the metal with high purity from the waste tin plating solution was carried out. First, tin plating waste solution was tested to remove the organic substances and metallic impurities such as Fe, Zn, Na etc. using ion exchange resin having iminodiacetic functional groups (Lewatit TP 207). Second, the tin solution was purified to obtain the high purity tin solution using ion exchange resin having ethylhexyl-phosphate functional groups (Lewatit VPOC 1026). Finally, 99.98% of the high purity of tin metal can be recovered from the purified solution by cyclone type electrowinning method.

Adsorption characterisctics of mixed resins for perchlorate ion (혼합수지를 이용한 과염소산 이온의 흡착 특성)

  • Park, Su-Min;Jeon, Byong-Hun;Jeong, Hyuk;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.429-436
    • /
    • 2010
  • The present research evaluates the efficiency of mixed resins between anion exchange resin and active carbon. We expected synergic effect from advantages of both adsorbents. Especially, this research focused on the removal of high cencentrated perchlorate ion from demilitarization solution. The total amount of the adsorbed perchlorate ion is increased considerably with mixed resins between mono functional anion exchange resin and granular active carbon from a single adsorbent. Results demonstated that this process not only improve the efficiency of adsorbing perchlorate, but save the time, space and cost for treating perchlotrate waste solution, because of reducing organic contaminant removing process. The interference effects from coexisting anions are not significant and can successfully applied to real demilitarization sample.

An Experimental Study on the Ion Reaction and the Electrochemical Rebar-Corrosion in Aqueous Solution Mixed with Sulfate and Chloride Ion-Reactive Material (황산, 염소이온 반응 소재 혼입 수용액에서의 이온반응성 및 전기화학적 철근 부식에 관한 실험적 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Kang, Tae-Won;Lim, Chang-Gil;Kim, Hong-Tae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this study, amine derivatives and ion exchange resins were selected to actively control penetration ions ($SO{_4}^{2-}$, $Cl^-$) as the element technology of repair materials for concrete structures in drainage environments. Ions ($SO{_4}^{2-}$, $Cl^-$) adsorption performance and corrosion resistance of calcium hydroxide solution with amine derivative and ion exchange resin were confirmed by ion chromatography and potentiostat analysis. As a result of the experiment, it was confirmed that the amine derivative is excellent in the adsorption of chlorine ion and the ion exchange resin is excellent in the adsorption of sulfate ion. It has been confirmed that corrosion resistance can be increased by proper combination of two materials in the calcium hydroxide solution containing sulfate ion and chloride ion simulating sewage environment.

Effect of pH on the binding of hGM-CSF to ion exchange resin

  • Myoung, Hyun-Jong;Lee, Sang-Yoon;Lee, Kyoung-Hoon;Han, Kyu-Boem;Kim, Dong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.320-323
    • /
    • 2003
  • The effects of pH on the binding of human granulocyte-macrophage colony-stimulating factor (hGM-CSF) expressed from transgenic plant cell suspensions to cationic and anionic exchange resins were investigated. In terms of stability, the optimum pH was found to be 5-7. In the case of using buffer exchange, when CM-sepharose was used as a cationic exchange resin, the best binding pH was 4.8 (77%) and when DEAE-sepharose was used as an anionic exchange resin, the best binding pH was 5.5 (74%). Without using buffer exchange, the optimum pH was 4.6 and the adsorption yield was 84%. From these results, a possibility of overcoming the degradation and instability of secreted protein product by in firm adsorption was found.

  • PDF

Study on the Elution Behavior of Rare Earth Elements by Cation Exchange Resin (양이온 교환수지에 의한 희토류 원소의 용리현상에 관한 연구)

  • Ki-Won Cha;Sung-Wook Hong;Kyung-Hwan Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.63-68
    • /
    • 1986
  • Elution behavior of rare earth elements have been investigated with the EDTA solution as an eluent using cation exchange resin. Definite amount of the complexed rare earth ions at pH 8.4 is adsorbed through the cation exchanger containing cupric ion as a retaining ion and eluted with EDTA solution. The rare earth ions are eluted more rapidly in the above method than in the method in which uncomplexed rare earth ions are adsorbed on the cation exchange resin bed. In this method, the elution time and amount of eluent are saved but the resolution values also decreased a little. The elution order of complexed ion was determined in accordance with the stability constant of complexes with rare earth elements.

  • PDF