• Title/Summary/Keyword: ion water

Search Result 2,590, Processing Time 0.028 seconds

Micro/nano Tribological and Water Wetting Characteristics of Ion Beam Treated PTFE Surfaces

  • Yoon, Eui-Sung;Oh, Hyun-Jin;Yang, Seung-Ho;Kong, Hosung
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.12-16
    • /
    • 2002
  • Micro/nano tribological and water wetting characteristics of ion beam treated PTFE (polytetrafluoroethylene) surfaces were experimentally studied. The ion beam treatment was performed with a hollow cathode ion gun at different argon ion dose conditions in a vacuum chamber to modify the topography of PTFE surface. Micro/nano tribological characteristics, water wetting angles and roughness were measured with a micro tribe tester, SPM (scanning probe microscope), contact anglemeter and profilometer, respectively. Results showed that surface roughness increased with the argon ion dose. Water wetting angle of the ion beam treated samples increased with the ion dose, so the surface shows an ultra-hydrophobic nature. Micro-adhesion and micro-friction depend on the wetting characteristics of the PTFE samples. However, nano-tribological characteristics showed different results. The scale effect of surface topography on tribological characteristics was discussed. Also, the water wetting characteristics of modified PTFE samples were discussed in terms of the surface topographic characteristics.

Evaluation of Toxicity Influenced by Ion Imbalance in Wastewater (폐수에서 이온불균형문제가 생태독성에 미치는 영향 평가)

  • Shin, Kisik;Kim, Jongmin;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.77-83
    • /
    • 2018
  • This paper aims to evaluate the results of toxicity testing with Daphnia magna and Vibrio fischeri on wastewater samples which might be influenced by ion imbalance. The effluents from factories were found to be more toxic with high salinity levels than those from public wastewater treatment plant (WTP) and sewage treatment plant (SWP). Clion composition was highest in the effluent, in terms of percentage, which was followed by $Na^+$, $SO_4^{2-}$ and $Ca^{2+}$. $K^+$ and $Mg^{2+}$ ion was relatively low. The sensitivity of D. magna test results was higher than V. fischeri. Among samples which were proved by V. fischeri testing to be nontoxic, the composition ratio of each ion whether toxic samples or nontoxic samples which were decided by D. magna toxicity testing, were compared. $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ ion composition ratio showed high level in nontoxic samples whereas $SO_4^{2-}$ and $Cl^-$ ion composition ratio was high in toxic samples. Accordingly, $SO_4^{2-}$ and $Cl^-$ ion seemed to be considered the ions causing toxicity in effluent. Toxicity from some categories of industries (Mining of non-metallic minerals, Manufacture of basic organic petrochemicals, Manufacture of other basic organic chemicals, Manufacture of other chemical products etc.) seemed to be influenced by salinity. The Ion concentration in influent and effluent were similar. Concentration of $Na^+$, $Cl^-$, $K^+$, $Ca^{2+}$ ions were high in influent, however $Mg^{2+}$ and $SO_4^{2-}$ ions were high in effluent.

Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer (고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

Fluorometric Quantitative Analysis of Al(III) Ion Using 5-Methoxy-2-phenyliminomethylphenol

  • Kim, Sun-Deuk;Lee, Hye-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1026-1030
    • /
    • 2009
  • A novel Schiff base ligand (N, O system) 5-methoxy-2-phenyliminomethylphenol ($5-CH_3O-PMP$) was synthesized. Using the synthesized ligand as a fluorescent reagent, a fluorometric method was developed for the quantitative analysis of Al(III) ion. The quantitative analysis of Al(III) ion was performed by making the complex compound between Al(III) ion and $5-CH_3O-PMP$ in ethanol-water solution (85/15, v/v, pH 6.2). The excitation wavelength (${\lambda}em$) of the complex compound was 397 nm while the emmision wavelength (${\lambda}em$) was 498 nm. The quantitative analysis of Al(III) ion was carried out by estimating the fluorescence intensity. The various calibration curves were used for the quantitative analysis in the range of 0.27$\sim$27 ng/mL Al(III) ion concentrations. The detection limit was 0.027 ng/mL. Using the fluorometric method developed in this study, satisfying results were obtained from various samples such as tap water, hot spring water, river water, sea water and waste water, which contained considerable amounts of interfering ions.

Characteristics of Removal of Perfluorinated Compounds (PFCs) Using Magnetic Ion Exchange Resin (MIEX®) in Water (자성체 이온교환수지(MIEX®)를 이용한 수중의 과불화화합물(PFCs) 제거 특성)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Kyung-A;Ryu, Sang-Weoun;Kwon, Ki-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.1009-1017
    • /
    • 2013
  • Perfluorooctanoic acid (PFOA) and perfluorooctyl sulfonate (PFOS) is a new persistent organic pollutants of substantial environmental concern. This study investigated the potential of magnetic ion exchange resin (MIEX$^{(R)}$) as the adsorbent for the removal of PFOA and PFOS from Nakdong River water. In our batch experiments, we studied the effect of some parameters (pH, temperature, sulfate concentration) on the removal of PFOA and PFOS. The results of sorption kinetics on MIEX$^{(R)}$ show that it takes 90 min to reach equilibrium but the economical contact time and dosage were 30 min and 10 mL/L. An increase in pH (pH 6~10) leads to a decrease in PFOA (2.0%) and PFOS (3.6%) sorption on MIEX$^{(R)}$. The sorption of both PFOA and PFOS decreases with an increase in ionic strength for sulfate ion (${SO_4}^{2-}$), due to the competition phenomenon. An increase in water temperature ($8^{\circ}C{\sim}28^{\circ}C$) in water leads to a increase in PFOA (2.8%) and PFOS (4.3%) sorption on MIEX$^{(R)}$. Based on the sorption behaviors and characteristics of the adsorbents and adsorbates, ion exchange and hydrophobic interaction were deduced to be involved in the sorption, and hemi-micelles possibly formed in the intraparticle pores.

Preparation and Characterization of Water-Soluble Glass through Melting Process (I) : Dissolution Characteristics, Bactericidal Effects and Cytotoxicity (용융법에 의한 수용성 유리의 제조 및 특성 (I) : 용해 특성, 살균 효과 및 세포 독성)

  • 조종호;이용근;최세영;신철수;김경남
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.10
    • /
    • pp.1093-1102
    • /
    • 1995
  • Water-soluble phosphate glasses containing Ag or Cu ion were prepared through melting process. Then the powdered glass samples were dissolved in D.I. water at room temperature with changing the dissolution time. In terms with the glass composition, dissolution characteristics, bactericidal effects and cytotoxicities were investigated. Dissolved amounts increased uniformly with dissolution time, and the dissolution rate was higher for ternary glass than for binary glass and with less metal oxide amount. And the dissolution rate of the glass with Ag ion was higher than that with Cu ion, and the bactericidal effect of the glass with Ag ion was also greater. Solution with more than 25 ppm of Ag was observed to have strong cytotoxicity to L929, and solutions of lower Ag concentration or with Cu seemed to have little cytotoxicity.

  • PDF

The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis (전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생)

  • 윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF

A Study on Electrostatic Discharging in Ultrapure and Electrolyzed Waters Using Kelvin's Thunderstorm Effect (캘빈방전 효과를 이용한 초순수 및 전해이온수의 정전기 방전 연구)

  • Kim, Hyung-won;Jung, Youn-won;Choi, In-sik;Choi, Byung-sun;Choi, Donghyeon;Ryoo, Kun-kul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.5-11
    • /
    • 2022
  • Despite the increasing importance of manufacturing and application R&D for ultrapure deionized water and electrolyzed ion water, various and systematic studies have not been conducted until now. In this study, the electrostatic discharge (ESD) behavior of electrolyzed ion water using a proton exchange membrane(PEM) was evaluated according to the type, flow rate, and bubble of electrolyzed ion water. In addition, by observing that Oxidation Reduction Potential (ORP) value returns to the unique value of electrolyzed ion water after electrostatic discharge, the possibility of two types of ions participating in electrostatic discharge ((H2O)n+ (assumed)) and ions for maintaining the characteristics of electrolyzed water could be inferred. In order to confirm the chemical structure and characteristics of the cations, in-depth research related to water molecular orbital energy or band gap should be followed.

A study on effects of water-cement ratio and crack width on chloride ion transmission rate in concrete

  • Li, Yue;Chen, Xiaohan;Zhang, Guosheng
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.387-394
    • /
    • 2017
  • To study the effects of water-cement ratio changes and cracks on chloride ion transmission rate in cracked concrete, RCM method was adopted to accelerate the diffusion of chloride ion in cracked concrete, and the changes in chloride ion concentration and around the cracks are inferred by finite-element method. The test results show that as far as prefabricated cracks on concrete components are concerned, the width thresholds of two cracks on the concrete specimens with a water-cement ratio of 0.5 and 0.6 are 0.05 mm and 0.1 mm respectively, the width threshold of two cracks on the concrete specimens with a water-cement ratio of 0.4 is 0.05 mm and 0.2 mm respectively; and the results of numerical simulation show that the smaller the water-cement ratio is, the more significant effects of cracks on chloride ion transmission rate are. As a result, more attention shall be paid to the crack prevention, repairing and strengthening for high-strength concrete.

Effects of Particle Size and Temperature on the Ammonium Ion Exchange by Natural Zeolite (천연제올라이트의 암모늄이온교환에 미치는 입자 크기 및 온도영향에 관한 연구)

  • Song, Chang Soo;Kim, Hee Jun;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.75-80
    • /
    • 1998
  • Ammonium ion is notorious for the adverse effects upon many of the important uses of water such as toxcity to fish, corrosion of metals and concrete, and concern over man's consumption. A clinoptilolite, which is a naturally occurring zeolite selective for ammonium ion exchange, has been used. Batch isotherm experiments were conducted for measuring ammonium ion exchange capacity. The ion exchange capacity was well described either by the Langmuir equation or by the Freundlich equation. As the particle size of the clinoptilolite decreased, exchange capacity was increased. The smaller particle size enhaced the exchange of ammonium ion due to the greater surface area and decreased diffusion to the exchange sites within the zeolite. Ammonium ion exchange capacity tended to decrease when the temperature increased from $20^{\circ}C$ to $35^{\circ}C$, and the temperature correction factor was found to be 0.98 in the Langmuir equation.

  • PDF