• Title/Summary/Keyword: ion sensitivity

Search Result 310, Processing Time 0.027 seconds

Ion-Pair Chromatography of Organic and Inorganic Anions (유기 및 무기음이온에 대한 이온쌍크로마토그래피)

  • Sam Woo Kang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.4
    • /
    • pp.365-371
    • /
    • 1985
  • A cationic dye, methylene blue $(MTB^+)$ was examined as a counter ion in the separation of organic and inorganic anions by ion-pair chromatography. Nonabsorbing anions could be indirectly detected by photometric detector with the assistance of MTB^+ in visible range (665nm). A mixture of anions was able to be separated with good base line resolution and high sensitivity. The capacity factors were also determined in various experimental conditions to study retention mechanism. The retention followed the ion-interaction model where the $MTB^+$ occupies a primary layer at the stationary phase while the analyte anion and other anions in the system compete for forming the secondary layer.

  • PDF

The optical characteristics of amorphous $Se_{75}Ge_{25}$ thin film by the low-energy lon beam exposure (저 에너지 이온빔 조사에 따른 비정질 $Se_{75}Ge_{25}$ 박막의 광학적 특성)

  • 이현용;오연한;정홍배
    • Electrical & Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.100-106
    • /
    • 1994
  • A bilayer film consisting of a layer of a-Se$_{75}$ Ge$_{25}$ with a surface layer of silver -100[.angs.] thick and a monolayer film of a-Se$_{75}$ Ge$_{25}$ are irradiated with 9[keV] Ga$^{+}$ ion beam. The Ga$^{+}$ ion (10$^{16}$ [ions/cm$^{2}$] exposed a-Se$_{75}$ Ge$_{25}$ and Ag/a-Se$_{75}$ Ge$_{25}$ thin films show an increase in optical absorption, and the absorption edge on irradiation with shifts toward longer wavelength. The shift toward longer wavelength called a "darkening effect" is observed also in film exposure to optical radiation(4.5*10$^{20}$ [photons/cm$^{2}$]). The 0.3[eV] edge shift for ion irradiation films is about twice to that obtained on irradiation with photons. These large changes are primarily due to structural changes, which lead to high etch selectivity and high sensitivity.

  • PDF

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.

Capacitance Enhancement and Evaluation of Gold-Deposited Carbon Nanotube Film Ion-Selective Electrode (금 입자 증착된 탄소나노튜브의 커패시턴스 증가 및 박막형 이온 선택성 전극으로서의 특성 평가)

  • Do Youn Kim;Hanbyeol Son;Hyo-Ryoung Lim
    • Journal of Powder Materials
    • /
    • v.30 no.4
    • /
    • pp.310-317
    • /
    • 2023
  • Small-film-type ion sensors are garnering considerable interest in the fields of wearable healthcare and home-based monitoring systems. The performance of these sensors primarily relies on electrode capacitance, often employing nanocomposite materials composed of nano- and sub-micrometer particles. Traditional techniques for enhancing capacitance involve the creation of nanoparticles on film electrodes, which require cost-intensive and complex chemical synthesis processes, followed by additional coating optimization. In this study, we introduce a simple one-step electrochemical method for fabricating gold nanoparticles on a carbon nanotube (Au NP-CNT) electrode surface through cyclic voltammetry deposition. Furthermore, we assess the improvement in capacitance by distinguishing between the electrical double-layer capacitance and diffusion-controlled capacitance, thereby clarifying the principles underpinning the material design. The Au NP-CNT electrode maintains its stability and sensitivity for up to 50 d, signifying its potential for advanced ion sensing. Additionally, integration with a mobile wireless data system highlights the versatility of the sensor for health applications.

Thermal Characteristics and Cooling Experiments and Analysis of Finite Elements in the Discharge of Lithium-Ion Batteries (리튬이온 배터리 방전 시 발열 특성 및 냉각 실험과 유한요소 해석)

  • Seokil Kim;Shin You Kang
    • Journal of Industrial Technology
    • /
    • v.43 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • Lithium-ion batteries are predominantly employed in electric vehicles and energy storage devices, offering the advantage of high energy density. However, they are susceptible to efficiency degradation when operated at high temperatures due to their sensitivity to the external environment. In this study, we conducted experiments using an indirect cooling method to prevent thermal runaway and explosions in lithium-ion batteries. The results were validated by comparing them with heat transfer simulations conducted through a commercial finite element analysis program. The experiments included single-cell exothermic tests and cooling experiments on a battery pack with 10 cells connected in series, utilizing 21700 lithium-ion batteries. To block external temperature influences, the experimental environment featured an extrusion method insulation in the environmental chamber. The cooling system, suitable for indirect cooling, was constructed with copper tubes and pins. The heat transfer analysis began by presenting a single-cell heating model using commercial software, which was then employed to analyze the heating and cooling of the battery pack.

Evaluation of Toxicity Influenced by Ion Imbalance in Wastewater (폐수에서 이온불균형문제가 생태독성에 미치는 영향 평가)

  • Shin, Kisik;Kim, Jongmin;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.77-83
    • /
    • 2018
  • This paper aims to evaluate the results of toxicity testing with Daphnia magna and Vibrio fischeri on wastewater samples which might be influenced by ion imbalance. The effluents from factories were found to be more toxic with high salinity levels than those from public wastewater treatment plant (WTP) and sewage treatment plant (SWP). Clion composition was highest in the effluent, in terms of percentage, which was followed by $Na^+$, $SO_4^{2-}$ and $Ca^{2+}$. $K^+$ and $Mg^{2+}$ ion was relatively low. The sensitivity of D. magna test results was higher than V. fischeri. Among samples which were proved by V. fischeri testing to be nontoxic, the composition ratio of each ion whether toxic samples or nontoxic samples which were decided by D. magna toxicity testing, were compared. $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ ion composition ratio showed high level in nontoxic samples whereas $SO_4^{2-}$ and $Cl^-$ ion composition ratio was high in toxic samples. Accordingly, $SO_4^{2-}$ and $Cl^-$ ion seemed to be considered the ions causing toxicity in effluent. Toxicity from some categories of industries (Mining of non-metallic minerals, Manufacture of basic organic petrochemicals, Manufacture of other basic organic chemicals, Manufacture of other chemical products etc.) seemed to be influenced by salinity. The Ion concentration in influent and effluent were similar. Concentration of $Na^+$, $Cl^-$, $K^+$, $Ca^{2+}$ ions were high in influent, however $Mg^{2+}$ and $SO_4^{2-}$ ions were high in effluent.

Biological Applications of Helium Ion Microscopy

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • v.43 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • The helium ion microscope (HIM) has recently emerged as a novel tool for imaging and analysis. Based on a bright ion source and small probe, the HIM offers advantages over the conventional field emission scanning electron microscope. The key features of the HIM include (1) high resolution (ca. 0.25 nm), (2) great surface sensitivity, (3) great contrast, (4) large depth-of-field, (5) efficient charge control, (6) reduced specimen damage, and (7) nanomachining capability. Due to the charge neutralization by flood electron beam, there is no need for conductive metal coating for the observation of insulating biological specimens by HIM. There is growing evidence that the HIM has substantial potential for high-resolution imaging of uncoated insulating biological specimens at the nanoscale.

Pt-and $TiO_2-doped\; Nb_2O_5$ Thin Film by Ion-Beam-Enhanced Deposition

  • Zhu, Jianzhong;Ren, Congxin
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.100-105
    • /
    • 1998
  • This paper describes the preparation of Pt-and $TiO_2$-doped $Nb_2O_5$ thin film by Ion-Beam-Enhanced Deposition. Platinum and titanium doping, and Nb2O5 deposition were carried out in situ. The dependence of oxygen sensing properties on the amounts of Pt and Ti dopant in the $Nb_2O_5$ film was investigated. There were the highist sensitivity, the lowest temperature coefficient and the shortest responce time at doping of 5 mol% $TiO_2$ and 0.3 mol%Pt

  • PDF

Analysis of Residual Pesticides in Herbal Drugs: GC/MS Analysis of 27 Controlled Pesticides (생약 중 잔류 농약의 분석법: GC/MS에 의한 27종 잔류 규제 농약의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Yoon, Hye-Ran;Yoon, In-Byoung;Cho, Sool-Yeon;Hwang, Gwi-Seo
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.141-148
    • /
    • 1996
  • GC/MS analysis of 27 controlled pesticides in herbal drugs was studied. Selected ion monitoring(sim) technique was applied to increase the GC/MS sensitivity. Typical peaks in th e mass spectrum of each pesticides were selected as quantitation, comfirmation or alternate ion. Twenty seven pesticides were divided into five groups according to their retention time and the peaks for SIM were programmed accordingly. The combination of two ionization methods, electron impact(EI)-SIM-MS and negative ion chemical ionization(NCI)-SIM-MS, were well-fitted for the detection, confirmation and quantitation of multiclass residual pesticides in herbal drugs.

  • PDF

A Pyrenylboronic Acid-based Fluorescence Sensor for Highly Efficient Detection of Mercury(II) Ions (효율적인 수은이온 검출을 위한 피렌-보론산 기반의 형광센서 개발)

  • Lee, Seung Yeob;Lee, Seoung Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.2
    • /
    • pp.201-207
    • /
    • 2020
  • A new chemosensor based on a self-assembled system has been devised to detect Hg2+ions efficiently. We demonstrated that the amphiphilic building blocks consisting of pyrene and boronic acid (1) aggregate in aqueous solutions and provide an outstanding sensing platform for sensitive detection. The self-assembled 1 exhibited high selectivity and sensitivity for Hg2+ion detection via fluorescence quenching, where the Hg2+ion detection ensued from a fast transmetallation of 1. The Stern-Volmer (SV) quenching constant for its fluorescence quenching by Hg2+ions was approximately 1.58 × 108 M-1. In addition, self-assembled 1 exhibited excellent sensing abilities at nano-molar concentration levels when tap water and freshwater samples were contaminated with of Hg2+ ions.