• Title/Summary/Keyword: ion release

Search Result 203, Processing Time 0.024 seconds

Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel (초내식성 스테인레스강의 금속이온용출특성 및 세포적합성)

  • Kim, Cheol-Sang;Park, Jin-Soo;Her, Erk;Khang, Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

Kinetic Energy Release in the Fragmentation of tert-Butylbenzene Molecular Ions. A Mass-analyzed Ion Kinetic Energy Spectrometric (MIKES) Study

  • Choe, Joong-Chul;Kim, Byung-Joo;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.2
    • /
    • pp.167-171
    • /
    • 1989
  • Kinetic energy release in the fragmentation of tert-butylbenzene molecular ion was investigated using mass-analyzed ion kinetic energy spectrometry. Method to estimate kinetic energy release distribution (KERD) from experimental peak shape has been explained. Experimental KERD was in good agreement with the calculated result using phase space theory. Effect of dynamical constraint was found to be important.

Drug Release Characteristics of Famotidine-Cationic Exchange Resin Complexes and Their Pharmacokinetics in Rats (파모티딘-양이온 교환수지 복합체의 약물방출 특성 및 흰쥐에서의 체내동태)

  • Shin, Dong-Sun;Song, Woo-Heon;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.4
    • /
    • pp.313-321
    • /
    • 1997
  • Ion exchange resin complexes of famotidine have been prepared by the reaction of famotidine solution with activated ion exchange resins. Complex formation efficiency between famotidine and ion exchange resin was about $80{\sim}90%$ in average, calculated by HPLC determination. Drug release characteristics from the resin complexes were evaluated by the modified percolation method. Famotidine release was dependent on the type of ion exchange resins. In the case of weakly acidic resin complexes, the cumulative released amount of famotidine was more than 90% for 1hr in pH 1.2 buffer solution. However, in the case of strongly acidic resin complexes, it was less than 5% for 3hr in the same medium. Strongly acidic resins revealed some advantages over weakly, acidic resins for overcoming instability of famotidine in gastric juice. In addition, strongly acidic resin complexes showed controlled release of famotidine in pH 6.8 buffer solution, showing the result of about 60 to 70% of drug release for 5hr. After oral administrations of famotidine-resin complexes to rats as dose of 40 mg equivalent/kg, the pharmacokinetic parameters of famotidine were obtained by model independent analysis and compared with those of famotidine solution or suspension. $C_{max}$ of famotidine-resin complex was lower than that of famotidine solution or suspension. MRT, MAT, and MDT of the complexes were greater than those of famotidine solution or suspension. From these results, it was expected that famotidine was released slowly from the complexes and absorbed continuously into systemic circulation. It was recognized that drug release from the complexes was the rate-limiting step in drug absorption, since there were close correlations between in vitro drug release and in vivo pharmacokinetic parameters.

  • PDF

Preparation and Release Characteristics of Dextromethorphan HBr Ion-exchange Albumin Microcapsule (브롬화수소산 덱스트로메토르판의 이온교환 알부민 마이크로캅셀의 제조 및 용출특성)

  • Ahn, Eun-Sun;Ku, Young-Soon;Kim, Kil-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.2
    • /
    • pp.111-116
    • /
    • 1991
  • Dextromethorphan HBr (DMP HBr) ion exchange albumin microcapsules were prepared by the interfacial polymerization method. The incorporation of drugs in empty albumin microcapsules was more increased in case of glutaraldehyde (GA) and formaldehyde (FA) than terephthaloyl chloride (TC) as a cross linking agent. The amount of DMP HBr incorporated into empty albumin micorcapsules was augemented with increasing DMP HBr concentration and the amount of empty microcapsules in the incorporation medium. Increasing the salt concentration in the release medium, the release rate and the DMP HBr amount released from microcapsules were increased. The release rates of DMP HBr from microcapsules retarded considerably compared with DMP HBr powder.

  • PDF

In Vitro Controlled Release of Piracetam with Coated Ion-Exchange Resin (이온교환수지를 이용한 피라세탐의 in vitro 방출조절)

  • Hwang, Young-Sook;Lee, Kyung-Tae;Seo, Seong-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.2
    • /
    • pp.105-109
    • /
    • 1999
  • The sustained release of piracetam by complexation with ion exchange resin was prepared. The complex was coated with Eudragit RS100 and their releases in vitro were conducted with various different kinds of medium solution. Dissolution rate increased as ionic strength, acidity and drug concentrations increased and reached its maximal plateau concentration within 5 min. Based on these data, The controlled release of piracetam using ion-exchange piracetam complex coated with Eudragit RS100 could be available.

  • PDF

Effect of Curing and Compression Process on the Drug Release of Coated Ion-Exchange Resin Complexes

  • Jeong, Seong-Hoon;Wang, Hun-Sik;Koo, Ja-Seong;Choi, Eun-Joo;Park, Ki-Nam
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • Ion exchange resins can be one of the good carriers for sustained drug release. However, the sustained release may not be enough only with themselves and hence film coating with rate controlling polymers can be applied to have a further effect on the drug release. Due to the environmental and economic issues of organic solvent for the polymer coating, aqueous polymeric systems were selected to develop dosage forms. Among the many aqueous polymeric dispersions for the film coating, EC (ethylcellulose) based polymers such as Aquacoat$^{(R)}$ ECD and Surelease$^{(R)}$ were evaluated.A fluid-bed coating was applied as a processing method. The drug release rate was quite dependent on the coating level so the release rate could be modified easily by changing different levels of the coating. The drug release rate in the Aquacoat$^{(R)}$ coated resin particles was strongly dependent on curing, which is a thermal treatment to make homogeneous films and circumvent drug release changes during storage. After dissolution test using the compressed tablets in which the coated resin particles are contained, inhomogeneous coating and even pores could be observed showing that the mechanical properties of EC were not resistant to granulation and compaction process. However, when tablets were prepared in different batches, the release profiles were almost identical showing the feasibility of the coated resin particle as incorporated into the tablet formulation.

Corrosion Protection from Inhibitors and Inhibitor Combinations Delivered by Synthetic Ion Exchange Compound Pigments in Organic Coatings

  • Chrisanti, S.;Ralston, K.A.;Buchheit, R.G.
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.212-218
    • /
    • 2008
  • Inorganic ion exchange compounds (IECs) including hydrotalcites and bentonite clays are a well known classes of layered mixed metal hydroxides or silicates that demonstrate ion exchange properties. These compounds have a range of applications from water purification to catalyst supports. The use of synthetic versions of these compounds as environmentally friendly additives to paints for storage and release of inhibitors is a new and emerging application. In this paper, the general concept of storage and release of inhibiting ions from IEC-based particulate pigments added to organic coatings is presented. The unique aspects of the IEC structure and the ion exchange phenomenon that form the basis of the storage and release characteristic are illustrated in two examples comprising an anion exchanging hydrotalcite compound and a cation exchanging bentonite compound. Examples of the levels of corrosion protection imparted by use of these types of pigments in organic coatings applied to aluminum alloy substrates is shown. How corrosion inhibition translates to corrosion protection during accelerated exposure testing by organic coatings containing these compounds is also presented.

Determination of the Kinetic Energy Release Originating from the Reverse Critical Energy in Unimolecular ion Dissociation

  • Yeh, In-Chul;Lee, Tae-Geol;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.3
    • /
    • pp.241-245
    • /
    • 1994
  • A method has been developed to estimate the kinetic energy release originating from the reverse critical energy in unimolecular ion dissociation. Contribution from the excess energy was estimated by RRKM theory, the statistical adiabatic model and the modified phase space calculation. This was subtracted from the experimental kinetic energy release distribution (KERD) via deconvolution. The present method has been applied to the KERDs in $H_2$, loss from $C_6H_6^+$ and HF loss from ${CH_2CF_2}^+$. In the present formalism, not only the energy in the reaction coordinate but also the energy in some transitional vibrational degrees of freedom at the transition state is thought to contribute to the experimental kinetic energy release. Details of the methods for treating the transitional modes are found not to be critical to the final outcome. For a reaction with small excess energy and large reverse critical energy. KERD is shown to be mainly governed by the reverse critical energy.

Wear Corrosion Behaviour of Nitrogen Ion Implanted Super Stainless Steel (질소이온주입된 초내식성 스테인리스강의 마모부식 특성)

  • Kang, Sun-Hwa;Kim, Cheol-Sang
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.175-177
    • /
    • 1994
  • The wear corrosion behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr - 20Ni - 6Mo - 0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The Cr and Ni amounts won out from the materials were investigated using an electrothermal atomic absorption spectrometry. We observed that the Cr dissolution rate of the S.S.S was similar to that of 316L SS, however, the Ni release of the S.S.S was feater than 316L SS. The metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. The wear corrosion behaviour of the stainless steels was not correlated with the results shown by a static metal ion release test.

  • PDF