• Title/Summary/Keyword: ion detection

검색결과 665건 처리시간 0.024초

열분무 LC/MS에 의한 인삼사포닌의 분석 (Analysis of Ginsenosides by Thermospray LC/MS)

  • Park, Man-Ki;Park, Jeong-Hill;Hwang, Gwi-Seo;Lee, Mi-Young;Park, In-Jeong
    • Journal of Ginseng Research
    • /
    • 제19권2호
    • /
    • pp.134-137
    • /
    • 1995
  • Ginseng saponins were analyzed by thermospray (TSP) LCMS method using ODS column and with acetonitrile/ammonium acetate solution. Optimal condition for TSP Lchfs was found as follows: capillary temperature: 33$0^{\circ}C$ repelled voltage: 200 V, and concentration of ammonium acetate: 0. 05 M. Panaxadiol and panaxatriol type saponins showed characteristic fragment ions. The calibration curve of ginseng saponin showed good linearity with a correlation coefficient of 0.99. Detection limits using selected ion monitoring (SIM) technique were improved by 10~200 times compared to conventional HPLCnnr detection method.

  • PDF

Free-standing 박막의 전계 방출 특성을 이용한 고에너지 이온 디텍터에 관한 연구 (Field Emission from Free-standing Nanomembrane For High Energy Ion Detection)

  • 박종후
    • 한국자기학회지
    • /
    • 제21권5호
    • /
    • pp.163-166
    • /
    • 2011
  • 기계적 자유도(mechanical degrees of freedom)를 가지는 free-standing 박막의 전계 방출 특성을 연구하였다. Free-standing 박막에서의 전계 방출 효과를 보다 정확히 해석하기 위하여 기계적 자유도(mechanical degrees of freedom)를 고려한 Fowler-Nordheim 전계 방출 식을 유도하였다. 새롭게 유도된 Fowler-Nordheim 식은 실험값과 매우 잘 일치한다. 이러한 free-standing 박막에서의 전계 방출 효과를 이용하여 이온화된 생체 분자의 충돌로 인해 발생된 free-standing 박막의 고주파 기계적 진동을 탐지함으로써 단백질 질량 분석기의 디텍터로 활용될 수 있음을 보였다.

3D CAD 모델을 이용한 이차 전지의 형상 결함 검출 (Geometrical Defect Detection of Secondary Battery Using 3-Dimensional CAD Model)

  • 조영호;류근호;이상열
    • Journal of Information Technology Applications and Management
    • /
    • 제29권6호
    • /
    • pp.135-144
    • /
    • 2022
  • In this study, we transformed 4680 type lithium-ion batteries to 3-dimensional CAD models and present a methodology to detect defects using Radon inverse transformation. Transparency was applied to the model to make it look like a CT image when viewed from the front. One normal and three defect models were created and analyzed. The models were saved as image files while rotating at a certain angle. Then, we used the Radon inverse transformation to reconstruct the original 3D geometry from the image files. Finally, we successfully found defects in the defect models for three cases.

질산이온 선택성 피복선 전극의 제작 및 환경분석에의 응용 (Preparation of Coated-Wire Nitrate Ion Selective Electrode and its Application for Environmental Analysis)

  • 李龍根;金昌圭;朴廷泰;金京燮;黃圭子
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.99-107
    • /
    • 1985
  • A coated wire ion selective electrode for nitrate (nitrate-CWE_ was constructed using epoxy resin, ion exchanger and plasticizer as a polymer membrane. It's stility, the composition of a polymer membrane, the response characteristics, the selectivity were examined and applied to the environmental analysis. The nitrate-CWE was prepared using a copper wire, wihch was coated with epoxy resin being incorporated with the nitrate ion exchanger and plasticizer. The best composition of the polymer membrane for the nitrate-CWE was obtained by mixing epoxy resin, ion exchanger and plasticizer in the ratio of 2:1:0.4. The potential (56.3$\pm$0.5 mV) of stick form nitrate-CWE in this composition was close to that (59.2 mV) of Nernstian response. The detection limit for nitrate ion were found to the about $6 \times 10^{-5}M$ and the useful pH was 2.5 $\sim$ 10.3. Furthermore, the selectivity of iodide and perchrorate for the nitrage-CWE was also much improved compared with that for a liquid membrane nitrate electrode. The nitrate-CWE was used to determind $NO_x$ in stack gas. The results were in good agreement with those obtained either by electrode method or by the improved NEDA method within a relative error of 4.0%.

  • PDF

Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

  • Park, Sehwan;Lee, Jihyeon;Cho, Soo Gyeong;Goh, Eun Mee;Lee, Sungman;Koh, Sung-Suk;Kim, Jeongkwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3659-3664
    • /
    • 2013
  • Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either $[M-H]^-$ for TNT and DNT or $[M]^{{\cdot}-}$ for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i.e., $[M+HCOO]^-$. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

Fluorometric Quantitative Analysis of Al(III) Ion Using 5-Methoxy-2-phenyliminomethylphenol

  • Kim, Sun-Deuk;Lee, Hye-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.1026-1030
    • /
    • 2009
  • A novel Schiff base ligand (N, O system) 5-methoxy-2-phenyliminomethylphenol ($5-CH_3O-PMP$) was synthesized. Using the synthesized ligand as a fluorescent reagent, a fluorometric method was developed for the quantitative analysis of Al(III) ion. The quantitative analysis of Al(III) ion was performed by making the complex compound between Al(III) ion and $5-CH_3O-PMP$ in ethanol-water solution (85/15, v/v, pH 6.2). The excitation wavelength (${\lambda}em$) of the complex compound was 397 nm while the emmision wavelength (${\lambda}em$) was 498 nm. The quantitative analysis of Al(III) ion was carried out by estimating the fluorescence intensity. The various calibration curves were used for the quantitative analysis in the range of 0.27$\sim$27 ng/mL Al(III) ion concentrations. The detection limit was 0.027 ng/mL. Using the fluorometric method developed in this study, satisfying results were obtained from various samples such as tap water, hot spring water, river water, sea water and waste water, which contained considerable amounts of interfering ions.

마스크의 중심 화소를 고려한 에지 검출에 관한 연구 (A Study on Edge Detection Considering Center Pixels of Mask)

  • 박화정;정회성;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.136-138
    • /
    • 2022
  • 에지 검출은 영상에 대하여 물체의 모양, 위치, 크기 및 재질 등과 같은 정보를 포함하고 있으며, 영상의 특징을 분석할 때 매우 중요한 요소이다. 기존의 에지 검출 방법에는 1차 미분을 이용한 소벨 필터(Sobel edge detection filter), 로버츠 필터(Roberts edge detection filter), 프리윗 필터(Prewitt edge detect ion filter) 등이 있으며, 2차 미분을 이용한 LoG(Laplacian of Gaussian) 등이 있다. 하지만 이러한 방법들은 전체 영상 영역에 대해 고정된 가중치 마스크를 적용하기 때문에 에지 검출 결과가 다소 미흡하다는 단점이 있다. 따라서 본 논문에서는 마스크 내의 중심 화소를 고려하여 에지 검출 특성을 높이는 에지 검출 알고리즘을 제안한다. 또한 제안한 에지 검출 성능을 확인하기 위하여 시뮬레이션 결과 영상을 통해 비교하였다.

  • PDF

High-Performance Liquid Chromatographic Determination of Cyclosulfamuron Residues in Soil, Water, Rice Grain and Straw

  • Lee, Young-Deuk;Kwon, Chan-Hyeok
    • 한국환경농학회지
    • /
    • 제23권4호
    • /
    • pp.251-257
    • /
    • 2004
  • Analytical methods were developed to determine cyclosulfamuron residues in soil, water, rice grain and straw using high-performance liquid chromatography (HPLC) with ultraviolet absorption detection. In these methods, cyclosulfamuron was extracted with aqueous $Na_2HPO_4$/acetone and acetone/methanol mixture from soil and rice samples respectively. Liquid-liquid partition coupled with ion-associated technique, Florisil column chromatography, and solid-phase extraction (SPE) were used to separate cyclosulfamuron from interfering co-extractives prior to HPLC analysis. For water sample, the residue was enriched in $C_{18}$-SPE cartridge, cleaned up in situ, and directly subjected to HPLC. Reverse-phase HPLC under ion-suppression was successfully applied to determine cyclo-sulfamuron in sample extracts with the detection at its ${\lambda}_{max}$ (254 nm). Recoveries from fortified samples averaged $87.8{\pm}7.1%$ (n=12), $97.3{\pm}7.2%$ (n=12), $90.8{\pm}6.6%$ (n=6), and $78.5{\pm}6.7%$ (n=6) for soil, water, rice grain and straw, respectively. Detection limits of the methods were 0.004 mg/kg, 0.001 mg/L, 0.01 mg/kg and 0.02 mg/kg for soil, water, rice grain and straw samples, respectively.