• Title/Summary/Keyword: iodine number

Search Result 116, Processing Time 0.026 seconds

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Effect of Postpartum Intrauterine Infusion of Povidone-iodine Solution on the Subsequent Reproductive Performance in Dairy Cows (분만 젖소의 자궁내 povidone-iodine 용액의 주입이 번식효율에 미치는 영향)

  • Lew, In-Cheon;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.337-341
    • /
    • 2007
  • This study determined the effect of postpartum intrauterine infusion of povidone-iodine solution on the subsequent reproductive performance in dairy cows. Six hundred and fifty-eight dairy cows that were around week 4 postpartum were randomly divided into two groups: (1) Cows in treated group received an intrauterine infusion of 100 to 150 ml 2% povidone-iodine solution (treated group, n=269), or (2) Cows that received no treatment were served as the controls (control group, n=389). The cows were bred at observed estrus more than 50 days after calving. Artificial insemination (AI) was done according to the a.m.-p.m. rule. The conception to AI was determined per rectum 60 days after AI by both ultrasonographical observation and manual palpation. The intervals from calving to first service and conception ($94.2{\pm}2.7$ and $144.1{\pm}4.1$ days vs. $88.0{\pm,}2.1$ and $143.5{\pm}4.6$ days, respectively), number of services per conception ($2.0{\pm}0.1$ vs. $2.1{\pm}0.1$), and cumulative pregnancy rates within 90 and 150 days postpartum (31.9 and 61.7% vs. 29.7 and 62.1%) did not differ between the control and treated groups (P>0.05), while conception rate at first service was lower (P<0.05) in the treated group (40.5%) than in the control group (49.4%). Additionally, we could not find any effect of intrauterine infusion of povidone-iodine solution according to cow parity or calving season on the reproductive performance. These results indicate that intrauterine infusion of povidone-iodine solution at week 4 postpartum does not affect the subsequent reproductive performance in dairy cows.

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

Observation on The Frequency of Chromosomal Aberration and Changes in Number of Peripheral Lymphocytes in Radioactive Iodine Treatment (방사성옥소 투여에 따른 말초혈액 림프구 수의 변화 및 염색체이상 빈도의 관찰)

  • Koo, Chun-Hee;Shin, Min-Ho;Park, Young-Ju;Lee, Jung-Yim;Park, Tae-Yong;Lee, Jae-Yong;Kim, Chong-Soon;Han, Seung-Soo;Kim, Kwang-Hoe;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.343-349
    • /
    • 1995
  • Background : For biological dosimetry of radiation exposure, both observing hematologic change and calculating Ydr by chromosomal analysis as biological indicators are widely used. However, due to the lack of studies on biological dosimetry of radiation dose absorbed in the body such as in the cases of radioactive iodine therapy, the maximal and safe dose is not well known, nor is the extent to which the body can safely endure radiation exposure. Purpose : To investegate the practical applicability of hematologic changes and Ydr as an indicator for estimating radiation exposure, to patients with thyroid diseases after doses of radioactive iodine. Material and Methods : 5 patients with hyperthyroidism and 35 patients who have had thyroid cancer operation were under treatment with radioactive iodine, changes in number of lymphocytes were tracked and Ydr was calculated for more than 2 months by chromosomal analysis in peripheral lymphocytes. Results ; 1) The number of lymphocytes began to decrease 2 weeks after doses of radioactive iodine, and reached the nadir after 6 and 8 weeks, then gradually recovered. 2) The nadir count of lymphocytes was reversely correlated with the administered dosage of radioactive iodine. 3) Ydr was generally stable between 2 and 8 weeks. 4) The maximal value of Ydr was correlated with the administered dosage of radioactive iodine. 5) Ydr value at the 2nd week increased with augmented dosage of radioactive iodine. 6) Ydr value at the 2nd week was correlated with fall of lymphocyte count. Conclusion : Patients must be closely observed, because temporary bone marrow suppression and slight chromosomal aberration can be produced by even generally used dosages of radioactive iodine for diagnosis and therapy. Maximal percent fall of lymphocyte count, Ydr at the 2 week interval and maximal Ydr can be used as the biological predictor of administered dosage of radioactive iodine.

  • PDF

Studies on the Syndiotactic Poly(vinyl alcohol) Polarizing Film -Iodine Desorption Behavior of High Molecular Weight Syndiotactic Poly(vinyl alcohol)/Iodine Complex Film- (신디오탁틱 폴리비닐알코올 편광필름에 관한 연구 - 고분자량 신디오탁틱 폴리비닐알코올/요오드 복합체 필름의 요오드 탈착 거동 -)

  • Lyoo, Won-Seok;Yeum, Jeong-Hyun;Choi, Jin-Hyun;Ji, Byung-Chul;Yoon, Won-Sik;Noh, Tae-Hwan;Ghim, Han-Do;Kim, Jae-Pil
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.115-121
    • /
    • 2001
  • High molecular weight syndiotactic poly(vinyl alcohol)(HMW s-PVA) with number-average degree of polymerization of 10000 and syndiotactic diad content of 61.5%/iodine complex film was prepared. Its adsorption and desorption behaviors of iodine in hot water were investigated. In comparison with atactic PVA film or low molecular weight s-PVA film, the degree of solubility of s-PVA film and the iodine desorption of HMW s-PVA/iodine film in hot water were limited to an extremely lower level. As the soaking time increased, the iodine desorption in hot water was increased. This reason might be explained by the fact that as the soaking time increased, so the iodine adsorption increased not by the stable molecular complex between PVA and iodine but by the simple physical adsorption of iodine.

  • PDF

The Study on the Physicochemical Properties of Fluid under High Pressure (1). Effects of Pressure and Temperature on the Pentamethyl Benzene-Iodine Charge Transfer Complex in n-HexaneⅠ

  • Kim, Jeong-Rim;Kwun, Oh-Cheun
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.74-79
    • /
    • 1985
  • The stabilities of the charge transfer complexes of pentamethyl benzene with iodine in n-hexane have been investigated by UV-spectrophotometric measurements at 25, 40 and 60$^{\circ}C$ up to 1600 bars. The equilibrium constant of the complex formation was increased with pressure while being decreased with temperature raising. Changes of volume, enthalpy, free energy and entropy for the formation of the complexes were obtained from the equilibrium constants. The red-shift at higher pressure, the blue-shift at higher temperature, and the relation between pressure and oscillator strength have been discussed by means of thermodynamic functions. In comparison with the results in the previous studies, the absolute values of ${\Delta}$V at each temperature were increased with the number of methyl groups of polymethyl benzene. However, it can be seen that both ${\Delta}$H and ${\Delta}$S show extreme behaviors in durene near atmospheric pressure but they are negatively increased with the number of methyl groups near 1600 bar. This order of the thermodynamic parameters may be a measure of the relative basicities of polymethyl benzenes toward iodine under each pressure, and these phenomena are explained in terms of a positive inductive effect and a steric hindrance effect of the polymethyl benzene molecule.

Additive Effects in Living Cationic Polymerization of tort-Butyl Vinyl Ether, initiated by Iodine

  • Jeon, Hyunjeong;Kwon, Soonhong;Han, Kyuchan;Mah, Soukil
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10a
    • /
    • pp.90-90
    • /
    • 2003
  • Living nature was appeared in the cationic polymerization of tort-butyl vinyl ether (TBVE), initiated by iodine, carried out in toluene at -78$^{\circ}C$. It was found that the number average molar mass of the resulting polymer (equation omitted) increases linearly as the conversion to polymer increase which reveals that there is no operation of chain transfer or termination process in this system. The polymers having narrow distribution and having molar mass of the resulting polymers are dependent on molar ratio of monomer and iodine.

  • PDF

The Charge Transfer Complexes of Monoalkylbenzene with Iodine in Carbon Tetrachloride (I)

  • Oh-Cheun Kwun
    • Bulletin of the Korean Chemical Society
    • /
    • v.1 no.2
    • /
    • pp.62-68
    • /
    • 1980
  • Ultraviolet spectrophotometric investigations have been carried out the systems of monoalkylbenzene with iodine in carbon tetrachloride. The results reveal the formation of one to one molecular complexes. The equilibrium constants for these complexes of representative monosubstituted benzene reveal the following order of increasing stability: benzene < methyl- < ethyl- < n-propyl-benzene. The value of ${\Delta}H$, ${\Delta}G$, and ${\Delta}S$ for interaction of a number of monoalkyl substituted benzene with iodine has been determinated. In general, as ΛH becomes increasingly negative, corresponding decreases in ${\Delta}G$ and ${\Delta}S$ values are observed, and these variation are linear. The thermodynamic constants become increasingly negative with increasing monoalkyl substitution of the aromatic donor nucleus. The complex bond is therefore weak, and its formation is accompanied by relatively small entropy changes.

The Study on the Physicochemical Properties of Fluid under High Pressure (Ⅱ). The Effect of Pressure and Temperature on the Hexamethyl Benzene-Iodine Charge Transfer Complex in n-Hexane

  • Kwun Oh Cheun;Kim Jeong Rim
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.4
    • /
    • pp.186-191
    • /
    • 1985
  • The effect of pressure and temperature on the stabilities of the charge transfer complexes of hexamethyl benzene with iodine in n-hexane has been investigated by UV-spectrophotometric measurements. In this experiment the absorption spectra of mixed solutions of hexamethyl benzene and iodine in n-hexane were measured at 25, 40 and $60^{\circ}C$ under 1,200, 600, 1200 and 1600 bar. The equilibrium constant of the complex formation was increased with pressure while being decreased with temperature raising. Changes of volume, enthalpy, free energy and entropy for the formation of the complexes were obtained from the equilibrium constants. The red shift at higher pressure, the blue shift at higher temperature and the relation between pressure and oscillator strength were discussed by means of thermodynamic functions. In comparison with the results in the previous studies, it can be seen that the pressure dependence of oscillator strength has a extremum behavior in durene as the variation of ${\Delta}H$ or ${\Delta}S$ with the number of methyl groups of polymethyl benzene near atmospheric pressure in the previous study. The shift or deformation of the potential in the ground state and in the excited state of the complexes formed between polymethyl benzene and iodine was considered from the correlation between the differences of the electron transfer energies and the differences of free energies of the complex formation for the pressure variation.

Thermodynamics of the Formation of Polynuclear Aromatics-Iodine Charge Transfer Complexes (여러고리 방향족 화합물과 요오드 사이의 전하이동 착물생성에 관한 열역학적 연구)

  • Oh Cheun Kwun;Jeong Rin Kim;Young Hoon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.575-581
    • /
    • 1985
  • Ultraviolet spectrophotometric investigations have been carried out on the systems of benzene, naphthalene and phenanthrene with iodine in carbon tetrachloride. The results reveal the formation of the one to one molecular complexes. The equilibrium constants were obtained in consideration of that absorption maxima due to the formation of the charge transfer complexes shift to blue with increasing temperature. Thermodynamic parameters for the formation of the charge transfer complexes were calculated from these values. These results indicate that the stabilities of the complexes formed between polynuclear aromatics and iodine increase with the number of aromatic rings. This may be a measure of the relative basicities of polynuclear aromatics toward iodine, which is explained in terms of the resonance of the interaction between aromatics and iodine. The results in this study were, additionally, compared with those of the polymethylbenzene series to be discussed the reason for them.

  • PDF