• 제목/요약/키워드: inverter topology

검색결과 376건 처리시간 0.03초

Step-up Switched Capacitor Multilevel Inverter with a Cascaded Structure in Asymmetric DC Source Configuration

  • Roy, Tapas;Bhattacharjee, Bidrohi;Sadhu, Pradip Kumar;Dasgupta, Abhijit;Mohapatra, Srikanta
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1051-1066
    • /
    • 2018
  • This study presents a novel step-up switched capacitor multilevel inverter (SCMLI) structure. The proposed structure comprises 2 unequal DC voltage sources, 4 capacitors, and 14 unidirectional power switches. It can synthesize 21 output voltage levels. The important features of the proposed topology are its self-voltage boosting and inherent capacitor voltage balancing capabilities. Furthermore, a cascaded structure of the proposed SCMLI with an asymmetric DC voltage source configuration is presented. The proposed topology and its cascaded structure are compared with conventional and other recently developed topologies in terms of different aspects, such as the required components to produce a specific number of output voltage levels, the total standing voltage (TSV) and peak inverse voltage of the structure, and the maximum number of switches in the conducting path. Furthermore, a cost function is developed to verify the cost-effectiveness of the proposed topology with respect to other topologies. The TSV of the proposed topology is significantly lower than those of other topologies. Moreover, the developed topology is cost-effective compared with other topologies. A detailed operating principle, power loss analysis, and selection procedure for switched capacitors are presented for the proposed SCMLI structure. Extensive simulation and experimental studies of a 21-level inverter structure prove the effectiveness and merits of the proposed SCMLI.

An Optimal Damping Control Algorithm of Direct Two-level Inverter for Miniaturization and Weight Reduction of Auxiliary Power Supply on Railway Vehicle

  • Lee, Chang-hee;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2335-2343
    • /
    • 2018
  • This paper proposes an optimal damping control algorithm of the DTI (Direct Two-level Inverter) to miniaturize and reduce the weight of auxiliary power supply for railway vehicles. The conventional auxiliary power supply for railway vehicles uses a DC-DC converter to maintain the inverter input power from the line voltage smoothly. The proposed topology does not use a DC-DC converter for reducing of manufacturing and maintenance costs. It also proposes a DTI topology removed damping resistors that generate ground signal noise in a certain period. At this time, a resonance phenomenon of DC-link voltage occurs due to variation of the inductive load, and a method of controlling the resonance phenomenon of DC-link voltage is required. In order to suppress the resonance phenomenon of the DC-link voltage, at a point before resonance occurs, this paper introduces an algorithm to suppress the resonance phenomenon of DC-link voltage by compensating the resonance component of the q axis voltage of the synchronous reference frame. The proposed algorithm verifies the effect through simulation and experiment.

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

500W급 순수사인파 인버터 설계 (Development of 500W Inverter with Pure Sine Wave Output)

  • 채용웅
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.61-68
    • /
    • 2018
  • 논문은 배터리로 구동되는 500W급의 순수사인파 단상인버터에 관한 연구이다. 푸쉬풀 토폴로지를 이용하여 배터리의 전압을 400V로 승압하고, 이 승압된 전압을 H-브리지를 이용하여 상용 220VAC를 출력하는 인버터 구조이다. 이러한 토폴로지를 이용하여 정격입력전압 12VDC에 500W의 인버터를 설계 제작하였다. 그 결과 효율은 일부구간에서 90%를 넘었으나 평균적으로는 약 89.5% 정도의 효율을 나타내고, 출력전압, 주파수 변동 오차 및 THD는 ${\pm}5%$ 미만의 결과를 얻을 수 있었다.

A Novel Photovoltaic Power Harvesting System Using a Transformerless H6 Single-Phase Inverter with Improved Grid Current Quality

  • Radhika, A.;Shunmugalatha, A.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.654-665
    • /
    • 2016
  • The pumping of electric power from photovoltaic (PV) farms is normally carried out using transformers, which require heavy mounting structures and are thus costly, less efficient, and bulky. Therefore, transformerless schemes are developed for the injection of power into the grid. Compared with the H4 inverter topology, the H6 topology is a better choice for pumping PV power into the grid because of the reduced common mode current. This paper presents how the perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) can be implemented in the H6 inverter topology along with the improved sinusoidal current injected to the grid at unity power factor with the average current mode control technique. On the basis of the P&O MPPT algorithm, a power reference for the present insolation level is first calculated. Maintaining this power reference and referring to the AC sine wave of bus bars, a sinusoidal current at unity power factor is injected to the grid. The proportional integral (PI) controller and fuzzy logic controller (FLC) are designed and implemented. The FLC outperforms the PI controller in terms of conversion efficiency and injected power quality. A simulation in the MATLAB/SIMULINK environment is carried out. An experimental prototype is built to validate the proposed idea. The dynamic and steady-state performances of the FLC controller are found to be better than those of the PI controller. The results are presented in this paper.

부유 인덕턴스를 고려한 새로운 유도 가열용 부하 공진형 인버터 (A New Load Resonant Inverter Topology Considering Stray Inductance Influences for Induction Heating)

  • 이병국;유상봉;서범석;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.416-419
    • /
    • 1995
  • An analysis of a new load resonant inverter considering stray inductance is given. There are several different types for load resonant inverters. They can offer zero turn-on as well as zero turn-off switching losses, yielding high efficiency at high power and high frequencies. However, they didn't consider the influences of stray inductance. In conventional topology using lossless snubber capacitor, stray inductances result in very high frequency resonant current. Especially, these influences can be problematic in high power system such as induction heating system with large current of some 10A associated with it. These currents increase EMI problem, give harmful effects in gate driver's operation and increase loss of dc-link capacitor as well as snubber capacitor. Therefore, the effect of stray inductances should be treated and reduced. This paper presents a new load resonant inverter topology, which can reduce the effect of stray inductances.

  • PDF

Novel Switched-Inductor Quasi-Z-source Inverter

  • Deng, Kai;Zheng, Jianyong;Mei, Jun
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.11-21
    • /
    • 2014
  • A novel switched-inductor quasi-Z-source inverter is proposed in this study. Compared with classic topologies, the boost ability of the proposed topology is strengthened. The voltage stress of the capacitors, diodes, and power devices are reduced, and the current ripple of the DC voltage source is suppressed. Conversion efficiency is also improved. The operation principle of the proposed topology is analyzed in detail and compared with that of similar topologies. The feasibility of the proposed topology is verified by simulations and experiments on a laboratory prototype.

LCD 백라이트용 트랜스포머 없는 냉음극관(CCFL) 구동 회로 (Transformer-less CCFL Driver for LCD Backlight)

  • 최은석;윤현기;문건우;윤명중;강문식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.81-83
    • /
    • 2006
  • The conventional cold cathode fluorescent lamp (CCFL) driver for LCD TV has a transformer for each lamp to step up the high sinusoidal waveform from the low input voltage. The transformer used in the conventional topology causes the driver to have bulky size and high cost. This paper proposes a new transformer-less CCFL driver for LCD backlight that is based on the parallel-loaded resonant inverter topology. This resonant topology enables the circuit to supply enough high voltage for CCFL without a transformer. Also, with current-balancing technique, this transformer-less inverter drives 16 CCFL lamps.

  • PDF

패널용 에어컨의 역률 개선 및 고조파 저감 (Power Factor Correction Improvement and Total Harmonic Distortion Reducing for Panel's Air-conditioner)

  • 박성우;박정우;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.258-261
    • /
    • 2001
  • High Power factor Active Filter converter is used for Inverter Air conditioner power supply to meet IEC standard. In the active filter topology for power factor, extra switch just control the input current indirectly to meet the IEC standard for reducing the cost and size. In this paper, low cost converter was suggested by simulation using extra switch which auxiliary pulse is inserted and quasi resonant soft switching topology control is adapted for panel's inverter air conditioner converter Inserting auxiliary Pulse method to the extra switch has the benefit of reducing THD by low cost input control circuit. And also quasi resonant soft switching topology can reduce switching loss. So both technical is suitable for Panel's Air conditioner.

  • PDF

An Extended Switched-inductor Quasi-Z-source Inverter

  • Deng, Kai;Mei, Fei;Mei, Jun;Zheng, Jianyong;Fu, Guangxu
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.541-549
    • /
    • 2014
  • In this paper, an extended switched-inductor quasi-Z-source inverter (ESL-qZSI) with high boost voltage inversion ability is presented, which combines the SL-qZSI with the traditional boost converter, as well as improves the switched-inductor cell. Compared with the classic qZSI topologies, the proposed topology reduces the voltage stresses of capacitors, power devices and diodes for the same input and output voltage. Furthermore, the conversion efficiency is improved. The operation principle of the proposed topology is analyzed in details, which is followed by the comparison between the three topologies. In addition, the performance of the proposed topology is verified by simulations and experiments.