• 제목/요약/키워드: inverter function

검색결과 330건 처리시간 0.025초

계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구 (Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System)

  • 김희중;정용호;이기수;전영수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

인버터 및 모터 인덕턴스를 이용한 PHEV 배터리 충전 기법 (Battery Charging Strategies for PHEVs using Motor Inductance and Multi-Function Inverter)

  • 우동균;최규영;김종수;이병국;강구배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.335-336
    • /
    • 2010
  • 본 논문에서는 Plug-in Hybrid Electric Vehicles (PHEVs)의 배터리 충전을 위해 필요한 추가적인 충전기 없이, 구동모터의 인덕턴스와 구동 드라이버인 3상 인버터를 이용하는 배터리 충전 기법을 소개한다. 모터의 인덕턴스를 승압용 에너지 저장장치로 사용하고 인버터의 스위칭 제어를 통해 부스트 컨버터로 사용하여 별도의 충전기를 제거함으로써 충전장치의 크기 및 단가를 저감할 수 있다. 상세한 유형별 이론적 분석과 시뮬레이션 결과를 제시하여 제안된 충전기법의 타당성을 검증한다.

  • PDF

DC-DC 전압 레귤레이터를 이용한 태양광전원의 효율향상 방안에 관한 연구 (A Study on the Efficiency Improvement Method of Photovoltaic System Using DC-DC Voltage Regulator)

  • 태동현;박재범;김미영;최성식;김찬혁;노대석
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.704-712
    • /
    • 2016
  • 최근, 전 세계적으로 신재생에너지에 대한 관심이 증가됨에 따라 친환경적이고 무한한 태양에너지를 이용하는 태양광전원의 설치가 급증하고 있다. 이러한 태양광전원은 주변 환경에 따라 출력이 크게 좌우되는데, 예를 들어 구름 또는 건물의 음영으로 인한 일부 모듈의 문제로 인해서 해당 스트링이 출력을 발생하지 못할 수 있다. 즉 기존의 제어방식에서는 모듈이 직렬로 연결된 스트링이 인버터에 연계되어 있으므로, 일부 모듈에 음영이 발생할 경우 스트링의 전압이 인버터의 동작전압 미만으로 되어 해당 스트링이 인버터에서 탈락되는 문제점이 발생할 수 있다. 따라서 본 논문에서는 각각의 스트링마다 전압을 제어하는 DC-DC 전압 레귤레이터를 이용하여, 스트링이 인버터에서 탈락되는 문제점을 개선하는 새로운 태양광전원 제어방식을 제안하였다. 또한, 회로해석 상용 프로그램인 PSIM S/W를 이용하여, 정전압 제어 및 MPPT(Maximum Power Point Tracking) 제어기능을 가지는 DC-DC 전압 레귤레이터와 위상동기루프(PLL, Phase-Locked Loop) 제어 기반의 3상 인버터의 모델링을 수행하였다. 이 모델링을 바탕으로 시뮬레이션을 수행한 결과, 부분적으로 음영이 발생하는 모듈을 가진 스트링이 인버터에서 탈락하는 현상을 개선함으로써 태양광전원의 운용효율이 향상됨을 확인하였다.

멀티플렉서 트리 합성이 통합된 FPGA 매핑 (FPGA Mapping Incorporated with Multiplexer Tree Synthesis)

  • 김교선
    • 전자공학회논문지
    • /
    • 제53권4호
    • /
    • pp.37-47
    • /
    • 2016
  • 광폭입력함수 전용 멀티플렉서가 슬라이스 구조에 포함되는 상용 FPGA의 현실적 제약 조건을 학계의 대표적 논리 표현 방식인 AIG (And-Inverter Graph)를 근간으로 개발된 FPGA 매핑 알고리즘에 적용하였다. AIG를 LUT (Look-Up Table)으로 매핑할 때 중간 구조로서 컷을 열거하는 데 이들 중에서 멀티플렉서를 인식해 낸 후 이들이 매핑될 때 지연 시간 및 면적을 복잡도 증가 없이 계산하도록 하였다. 이 때 트리 형성 전제 조건인 대칭성과 단수 제약 요건도 검사하도록 하였다. 또한, 멀티플렉서 트리의 루트 위치를 RTL 코드에서 찾아내고 이를 보조 출력 형태로 AIG에 추가하도록 하였다. 이 위치에서 섀넌확장을 통해 멀티플렉서 트리 구조를 의도적으로 합성한 후 최적 AIG에 겹치도록 하는 접근 방법을 최초로 제안하였다. 이때 무손실 합성을 가능하게 하는 FRAIG 방식이 응용되었다. 두 가지 프로세서에 대해 제안된 접근 방법과 기법들을 적용하여 약 13~30%의 면적 감소 및 최대 32%까지의 지연 시간 단축을 달성하였다. AIG 트리에 특정 구조를 의도적으로 주입시키는 접근 방법은 향후 캐리 체인 등에 확장 적용하는 연구가 진행될 것이다.

태양광발전의 운용효율 향상을 위한 DC/DC 전압 레귤레이터의 구현 및 특성분석 (Implementation and Characteristic Analysis of DC/DC Voltage Regulator for Operation Efficiency Improvement in PV system)

  • 김찬혁;최성식;강민관;정영문;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.201-208
    • /
    • 2017
  • 최근, 전 세계적으로 신 재생에너지에 대한 관심이 증가됨에 따라 친환경적이고 무한한 태양에너지를 이용하는 태양광 발전의 설치가 매년 급증하고 있다. 그러나, 태양광발전시스템은 일반적으로 태양광 전지에서 발생한 에너지로부터 전력변환장치(DC/AC)를 거쳐 계통연계 지점까지 약 25[%]의 전력손실을 발생시키고 있다. 이 전력손실 가운데, 일부 태양광 모듈에 음영이나 환경변화(일사량, 온도, 습도 등)로 인해 스트링의 출력 전압이 인버터의 동작전압보다 낮아지면 해당 스트링이 동작하지 않아 전체의 발전효율이 감소하거나, 최악의 경우 인버터가 탈락되어 계통의 출력 전력이 저하되는 등의 손실이 큰 부분을 차지하고 있다. 따라서, 본 논문에서는 상기의 문제점을 개선하기 위하여, 각각의 스트링별로 DC/DC 전압 레귤레이터를 도입하여 환경변화에 따른 전압 저하로 발생하는 스트링의 탈락을 방지하는 제어방식을 제시하였고, 기존 인버터의 MPPT(P&O) 제어와 정전압 제어기능을 전압 레귤레이터에서 수행하는 방식을 채택하였다. 또한, 제안한 알고리즘을 바탕으로 2kW급의 전압 레귤레이터를 구현하여 기존의 운용방식과 비교, 분석한 결과, 환경변화에 따른 다양한 시나리오에서 제안한 운용방식의 운용효율이 크게 향상됨을 확인하였다.

철도차량 보조전원장치의 순시전압제어 (Instantaneous Voltage Control Scheme of Auxiliary Power Supply System for Electric Railway Vehicles)

  • 김재식;최재호;임성수;이은규
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.349-356
    • /
    • 1999
  • 본 논문에서는 철도차량용 보조전원장치에 순시전압제어기법을 적용할 때 발생하는 문제들의 해결방안을 제시한다. 비선형부하나 과도상태에서 빠른 응답특성을 얻기 위해 순시전압제어기법을 사용할 때 LC 필터의 공진문제와 존재하는 정상상태 오차가 더욱 심각해진다. 인버터 출력측 LC 필터에 기인하는 공진현상을 억제하기 위해 전압전달함수의 제동비를 증가시키기 위한 방안으로 필터 커패시터 궤환제어기가 고려되었다. 그리고 교류전압 순시제어시 존재하는 정상상태 오차를 제거하기 위하여 고이득 전달함수를 기존의 PI 제어기에 첨가하였다. 이론적인 분석이 시뮬레이션 결과와 함께 잘 설명되어져 있다. 제안된 기법의 타당성을 5kVA급 시제품에 대한 시뮬레이션과 실험을 통하여 입증하였다.

  • PDF

액티브 필터기능을 갖는 3상 태양광 발전시스템의 단독운전 방지기능의 분석 (Analysis results of the Anti-islanding Function for PV-AF System)

  • 김경훈;서효룡;장성재;박상수;박민원;유인근;전진홍;김슬기;조창희;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1085-1086
    • /
    • 2008
  • Shunt active filter can compensate harmonic current of utility results from non-linear loads such as rectifiers, cycloconverters and arc furnaces. It has the same structure as photovoltaic(PV) generation system. So, It was proposed the system that generates PV power and also has active filter function. It is called PV-AF(Photovoltaic and Active Filter) power generation system. Islanding can be occurred in an inverter based dispersed generation system, when the system disconnected from utility and loads are entirely supplied by PV system only. Islanding may result in interference to grid protection devices, equipment damage, and even personnel safety hazards. Therefore, islanding has to be detected and protected. The conventional anti-islanding methods have NDZ(None-Detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, a novel anti-islanding method for PV-AF system is proposed and analysed in detail.

  • PDF

Study on Change of Poly ADP Ribose Polymerase in the Rat with Thrombotic Stroke by Full Wave Cockroft Walton method's Transcranial Magnetic Stimulation

  • Kim, Whi-Young;Kim, Jun-Hyoung
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.20-27
    • /
    • 2014
  • This study examined the relationships between protein expression and Poly ADP ribose polymerase in brain cell death in brains damaged by thrombotic stroke and treated with the Full Wave- Cockroft Walton (FWCW) method of Transcranial Magnetic Stimulation (TMS). The two-way switching element for TMS drove a half-bridge inverter of the current resonance of direct current voltage (+) and direct current voltage (-), and the experiment was conducted by stimulating the mice with thrombotic stroke through a range of pulses. Thrombotic stroke was caused of ligation of the common carotid artery of male SD mice, and blood reperfusion was conducted five minutes later. Protein expression was examined in immune reaction cells, which reacted to an antibody to Poly ADP ribose polymerase in the cerebrum cells, and western blotting. Observations of the PARP changes after thrombotic stroke showed that the number of Poly ADP ribose polymerase reactions were significantly lower (p < 0.05) in the group treated with TMS of the FWCW than the group with thrombotic stroke 24 hours after its onset. The application of FWCW-TMS helped prevent the necrosis of nerve cells and might prevent the brain damage that occurs as a result of thrombotic stroke, and improve the function recovery and disorder of brain cells.

비대칭 결합 마이크로스트립 선로를 이용한 능동 다이플렉서의 구현 (Design and Implementation of Active Diplexer Using Asymmetrical Coupled Microstrip Lines)

  • 윤현보;문승찬;최원영
    • 한국전자파학회지:전자파기술
    • /
    • 제4권3호
    • /
    • pp.11-17
    • /
    • 1993
  • 비대칭 결합선로를 이용한 대역통과 필터와 MESFET으로 구성되는 능동 다이플렉서를 실현하였다. 여기서 비대칭 결합 마이크로스트립 선로의 어드미턴스 인버터 파라미터는 대역통과 펼터의 기본적인 설계 파라미터에 대한 함수로서 주어진다. 능동 다이플렉서는 중심주파수 9 GHz와 11 GHz에서 각각 대역폭 22%와 18%로 설계하였고, Super-compact를 이용하여 설계값을 최적화하였다. 실험 결과 8.3-9.6 GHz와 10.3-11.8 GHz의 각대역에서 $6.2\pm0.3$ dB의 균일한 이득을 얻었고, 이 결과 는 대역폭은 잘 일치하나 이득은 설계값보다 1.5 dB 정도의 차이가 있었다.

  • PDF

멀티에어컨의 성능평가 및 제어시스템 개발에 대한 연구 (Development of Performance Evaluation and Control System of Multi-Air Conditioner)

  • 이한원;고국원;권영철;이중현;이유진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1107-1114
    • /
    • 2005
  • The running condition of multi-system air conditioner is prone to vary largely as it is designed for individual conditioning in each space of middle and small sized buildings. This leads to overcooling in case of partial load run, while the lack of capacity happens in case of full load run. Besides these, there exist such problems as instabilities due to the uneven refrigerant distribution caused by fluctuation of load and the change in piping line. Based upon the basic study on the function characteristics found in parts needed for maximized system working design in order to troubleshoot, the system functioning pattern should be identified through the different tests with various operating circumstances and the analysis models should be developed. With this ground, the control logic has to be made to have a control over capacity and make possible the efficient distribution of refrigerant.

  • PDF