• 제목/요약/키워드: inversion intensity

검색결과 83건 처리시간 0.024초

Tethersonde와 기상탑 관측 자료를 이용한 울산지역 야간 역전에 따른 대기오염도 변화와의 관계 (Nocturnal Inversion Layer observed by Tethersonde and AWS System and its Relation to Air Pollution at Ulsan)

  • 임윤규;김유근;오인보;송상근
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.555-563
    • /
    • 2005
  • This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003, The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0,76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone $(O_3)$ concentration was lower, while nitrogen dioxide $(NO_2)$ concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide $(SO_2)$ concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.

Meteorological Factors Affecting Winter Particulate Air Pollution in Ulaanbaatar from 2008 to 2016

  • Wang, Minrui;Kai, Kenji;Sugimoto, Nobuo;Enkhmaa, Sarangerel
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권3호
    • /
    • pp.244-254
    • /
    • 2018
  • Ulaanbaatar, the capital of Mongolia, is subject to high levels of atmospheric pollution during winter, which severely threatens the health of the population. By analyzing surface meteorological data, ground-based LIDAR data, and radiosonde data collected from 2008 to 2016, we studied seasonal variations in particulate matter (PM) concentration, visibility, relative humidity, temperature inversion layer thickness, and temperature inversion intensity. PM concentrations started to exceed the 24-h average standard ($50{\mu}g/m^3$) in mid-October and peaked from December to January. Visibility showed a significant negative correlation with PM concentration. Relative humidity was within the range of 60-80% when there were high PM concentrations. Both temperature inversion layer thickness and intensity reached maxima in January and showed similar seasonal variations with respect to PM concentration. The monthly average temperature inversion intensity showed a strong positive correlation with the monthly average $PM_{2.5}$ concentration. Furthermore, the temperature inversion layer thickness exceeded 500 m in midwinter and overlaid the weak mixed layer during daytime. Radiative cooling enhanced by the basin-like terrain led to a stable urban atmosphere, which strengthened particulate air pollution.

장주기 변광성의 SiO 메이저 선 세기 변화 연구 : 메이저 펌핑 기작 (INTENSITY VARIATION OF THE SiO MASER LINE OF LONG PERIOD VARIABLES : MASER PUMPING MECHANISM)

  • 김은혁;이상각
    • 천문학논총
    • /
    • 제8권1호
    • /
    • pp.83-104
    • /
    • 1993
  • In principle, both radiation and collision are capable of pumping the SiO masers. In order to check which pumping mechanism is more efficient, we calculated the rate equation for our model including the 3 vibrational slates with 7 rotational states of each vibrational slate. Through solving the radiative transfer equation with the Sovolev approximation, we estimated the line profiles from an expanding envelope for several transitions. It is found that the collision works more efficiently than the radiation for the inversion in excited vibrational stales. However in an expanding envelope model we could not get the strong line intensity as observed one because the population inversion is possible only in a small restricted region. For the enough population inversion to get type observed maser intensity. the number density of SiO and hydrogen molecules should be up to about $2{\times}10^5\;cm^{-3}$ and $1{\times}10^9\;cm^{-3}$, respectively, and the inversion should be occured in the region of no Jess than 11014cm.

  • PDF

김해에서 관측한 접지역전층의 특성에 관한 연구 (A Study on the Characteristics of Inversion Layer Observed at Kimhae)

  • 박종길;원경미
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.305-315
    • /
    • 1994
  • The field observation was carried out to investigate the characteristics of surface inversion layer at Kimhae using the feild observed date and upper layer meteorological data during 4-5 February 1993. The results of the study can be summarized as follows : The maximum height of surface inversion layer observed at Kimhae is 193m and the height of upper level inversion layer ranges from 2nm to 300m. The surface weather elements was influenced the formation of surface inversion layer. According to the pasquill stability and time variation of temperature with height, both the surface heating from insolation and the disturbance of upper level of inversion layer was influenced the disappearance of inversion layer. And the stability of surface temperature inversion layer generally belongs to the class of F, that of upper level temperature inversion layer commonly to the class of E.

  • PDF

복사/난류간 상호작용이 고려된 화염의 온도 및 농도분포의 SRS 역계산 (SRS Inversion of Flame Temperature/concentration Profile with Radiation/Turbulence Interaction)

  • 고주용;김현걸;송태호
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.891-897
    • /
    • 2006
  • The SRS method is applied to a turbulent flame with radiation/turbulence interaction to invert the temperature and concentration profile. The flame is conditioned as optically thin per each fluctuation length and the flame spectral intensity is measured for inversion. From inversion result, we find that SRS can successfully invert the coupled temperature/concentration fluctuation amplitudes. For two cases of experiments, inverted values are within approximately 1% over the full range of fluctuation amplitude. However, SRS cannot find the detailed local fluctuation parameters such as pattern and phase, etc. as far as they do not affect the resulting radiation intensity. Important available parameters are the mean temperature and the temperature fluctuation amplitude. The radiation/turbulence interaction effect is verified to play an important role in the radiation.

광 펄스 왜곡의 보상을 위해 Mid-Span Spectral Inversion 기법을 채택한 120 Gbps WDM 시스템에서 채널간 상호 위상 변조 현상의 영향 (Cross Phase Modulation Effects on 120 Gbps WDM Transmission Systems with Mid-Span Spectral Inversion for Compensation of Distorted Optical Pulse)

  • 이성렬;권순녀;이윤현
    • 한국전자파학회논문지
    • /
    • 제14권7호
    • /
    • pp.741-749
    • /
    • 2003
  • 광섬유의 색 분산과 자기 위상 변조 외에 상호 위상 변조 효과에 의해 왜곡된 WDM 채널 신호가 MSSI (Mid-Span Spectral Inversion) 기법을 통해 보상되는 정도를 다양한 광섬유 분산 계수를 고려하여 분석해 보았다. 본 연구에서 고려된 시스템은 120 Gbps (3$\times$40 Gbps) 강도 변조 직접 검파 방식의 WDM 시스템이다. 또한 전체 전송로의 중간에 비선형 매질로 HNL-DSF(Highly nonlinear dispersion shifted fiber)를 갖는 광 위상 공액기를 두고, 광 위상 공액기를 중심으로 첫 번째 전송 구간에서의 평균 강도와 두 번째 전송 구간에서의 평균 강도를 같게 하는 PAIA(Path Averaged Intensity Approximation) 방식 의 MSSI 기법을 채택한 시스템이다. 채널별 보상 특성의 분석은 1 dB 기준 눈 열림 패널티(Eye Opening Penalty)를 이용했다. 색 분산과 비선형 효과에 의한 채널 신호 왜곡이 유도될 수 있는 장거리 WDM 시스템에 MSSI 기법을 적용하면 전송 거리와 전송 품질을 단일 채널 전송 이상으로 개선시킬 수 있고, 상호 위상 변조에 의한 왜곡의 보상 측면에서 MSSI 기법은 광섬유의 분산 계수가 비교적 큰 WDM 시스템에 더욱 유효하다는 것을 확인할 수 있었다.

경로 평균 강도 근사 기법의 MSSI를 채택한 WDM 시스템에서 HNL-DSF를 갖는 광대역 광 위상 공액기 (Wideband Optical Phase Conjugator using HNL-DSF in WDM Systems with Path-Averaged Intensity Approximation Mid-Span Spectral Inversion)

  • 이성렬;이윤현
    • 한국항행학회논문지
    • /
    • 제7권1호
    • /
    • pp.14-21
    • /
    • 2003
  • 장거리 $3{\times}40$ Gbps 강도 변조 직접 검파 방식의 파장 분할 다중 시스템에서 색 분산과 자기 위상 변조에 의한 광 펄스 왜곡을 최상으로 보상할 수 있는 최적의 펌프 전력을 컴퓨터 시뮬레이션을 통해 살펴보았다. 본 논문에서 고찰한 파장 분할 다중 시스템은 전체 전송로 중간에 HNL-DSF (highly nonlinear dispersion shifted fiber)의 광 위상 공액기를 두어 광 신호 왜곡을 보상하는 경로 평균 강도 근사 (PAIA : Path-Averaged Intensity Approximation) 기법의 MSSI (Mid-Span Spectral Inversion)가 적용된 시스템이다. 우선 HNL-DSF는 광대역 파장 분할 다중 전송에서 매우 유용한 비선형 매질이라는 것을 확인할 수 있었고, 두 번째 광 전송로로 입사되는 공액파의 전력을 입력 광 신호의 전력과 같아지게 하는 HNL-DSF 광 위상 공액기의 펌프 전력에서 최상의 보상이 얻어지는 것을 확인할 수 있었다. 결과적으로 PAIA MSSI 기법에 전송 거리에 관계한 최적 펌프 전력을 갖는 HNL-DSF 광 위상 공액기를 적용하면 장거리 대용량 파장 분할 다중 시스템의 구현이 가능하다는 것을 확인할 수 있었다.

  • PDF

차량 자력탐사에서 차량의 영향의 제거 (Elimination of car's magnetic effect as noise in a car-borne magnetic exploration system)

  • 임무택;박영수;정현기;임형래;구성본;이영철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.141-151
    • /
    • 2006
  • 차량이 자력계를 끌면서 자기장을 측정하는 자력탐사시스템에서 차량 자체가 발생하는 잡음으로서의 자기장을 제거하기 위한 실험을 하였다. 차량 자체의 잔류자기 및 유도자기를 추출하기 위하여, 먼저 자력계를 고정된 점에 두고 차량을 이동하면서 자기장을 측정하였고, 이 자료로부터 차량을 고정된 점에 두고 자력계를 이동하면서 측정한 자료로 만들었으며, 후자의 자료로부터 역산을 통하여 차량 자체의 잔류자기 및 유도자기를 계산하였다. 한편, 차량 자력탐사시스템으로 측정한 각 측점의 자료로부터, 역산으로부터 계산한 차량 자체의 잔류자기 및 유도자기에 의해 발생하는 잡음으로서의 영향을 벡터적으로 제거 즉, 보정하여 자력이상을 추출하였다.

  • PDF

상호 위상 변조에 의해 왜곡된 WDM 신호의 Mid-Span Spectral Inversion을 이용한 보상 (Compensation of Distorted WDM signals due to Cross Phase Modulation Effects using Mid-Span Spectral Inversion)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제7권2호
    • /
    • pp.128-134
    • /
    • 2003
  • 광섬유의 색 분산과 자기 위상 변조 외에 상호 위상 변조 효과에 의해 왜곡된 WDM 채널 신호가 MSSI(Mid-Span Spectral Inversion) 기법을 통해 전송 거리에 따라 보상되는 정도를 다양한 광섬유 분산 계수를 고려하여 분석해 보았다. 본 연구에서 고려된 시스템은 전체 전송로의 중간에 비선형 매질로 HNL-DSF (Highly nonlinear dispersion shifted fiber)를 갖는 광 위상 공액기를 두고, 광 위상 공액기를 중심으로 첫 번째 전송 구간에서의 평균 강도와 두 번째 전송 구간에서의 평균 강도를 같게 하는 PAIA (Path Averaged Intensity Approximation) 방식의 MSSI 기법을 채택한 $3{\times}40$ Gbps 강도 변조 직접 검파 방식의 WDM 시스템이다. XPM에 의한 왜곡의 보상 측면에서 광섬유의 분산 계수가 비교적 큰 WDM 시스템일수록 MSSI 기법이 더욱 효과적으로 적용되어 전송 거리를 신장시킬 수 있는 것을 확인할 수 있었다. 또한 색 분산, SPM 외에 XPM의 영향을 받아 왜곡된 채널 신호는 MSSI 기법을 통해 광섬유의 분산 계수가 큰 시스템에서 더욱 안정되게 보상된다는 것을 알 수 있었다.

  • PDF

A Potential Diagnostic Pitfall in the Differentiation of Hemorrhagic and Fatty Lesions Using Short Inversion Time Inversion Recovery: a Case Report

  • Kim, Jee Hye;Kang, Woo Young;Cho, Bum Sang;Yi, Kyung Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.181-184
    • /
    • 2016
  • Short inversion time inversion recovery (STIR) is widely used for spinal magnetic resonance imaging (MRI) because the pulse sequence of STIR is insensitive to magnetic field inhomogeneity and can be used to scan a large field of view. In this case report, we present a case of spinal epidural hematoma with unexpected signal decrease on a STIR image. The MRI showed an epidural mass that appeared with high signal intensity on both T1- and T2-weighted images. However, a signal decrease was encountered on the STIR image. This nonspecific decrease of signal in tissue with a short T1 relaxation time that is similar to that of fat (i.e., hemorrhage) could lead to a diagnostic pitfall; one could falsely diagnose this decrease of signal as fat instead of hemorrhage. Awareness of the nonselective signal suppression achieved with STIR pulse sequences may avert an erroneous diagnosis in image interpretation.