• Title/Summary/Keyword: introduction to engineering design

Search Result 461, Processing Time 0.028 seconds

Seismic assessment and retrofitting of existing structure based on nonlinear static analysis

  • Ni, Pengpeng
    • Structural Engineering and Mechanics
    • /
    • v.49 no.5
    • /
    • pp.631-644
    • /
    • 2014
  • Seismic assessment and retrofitting of existing structure is a complicated work that typically requires more sophisticated analyses than performing a new design. Before the implementation of a Code for seismic design of buildings (GBJ 11-89), not enough attention has been paid on seismic performance of structures and a great part of the existing reinforced concrete structures built in China have been poorly designed according to the new version of the same code (GB 50011-2010). This paper presents a case study of seismic assessment of a non-seismically designed reinforced concrete building in China. The structural responses are evaluated using the nonlinear static procedure (the so-called pushover analysis), which requires its introduction within a process that allows the estimation of the demand, against which the capacity is then compared with. The capacity of all structural members can be determined following the design code. Based on the structural performance, suitable retrofitting strategies are selected and implemented to the existing system. The retrofitted structure is analyzed again to check the effectiveness of the rehabilitation. Different types of retrofitting strategy are discussed and classified according to their complexity and benefits. Finally, a proper intervention methodology is utilized to upgrade this typical low-rise non-ductile building.

Implementation of Customized EPM for Collaborative Resource Procurement in Small and Medium Size Plant Construction Enterprises (중소플랜트기업의 협업자원조달을 위한 Customized EPM구현)

  • Nam, Jung-Tai;Kim, Sung-Hun;Han, Young-Geun
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.133-141
    • /
    • 2008
  • The need for total enterprise management that covers from accepting orders, design, cost, procurement, manufacture, and delivery has been recently raised in order for efficient project management of small and medium size plant construction enterprises. This trend is reflected in the introduction of EPM(Enterprise Project Management) solutions by some shipbuilding enterprises and large construction corporations. In step with the trend, small and medium size plant construction enterprises are enabled to provide knowledge base in terms of reducing cost and production period and managing portfolio for accepting orders and attaining contract by inducing customized EPM This study presents a design of customized EPM based on a case study of a company. It exhibits a collaborative/collaboration resource-supply model which can be universally applied to small and medium size job-order production enterprises. The research discusses that under the assumption that information is shared internally between departments on planning, supply, manufacture, and quality control in order to create collaborative environment and close participation is created externally between suppliers and orderers, productivity can be improved in cost reduction through planning efficient collaborative supply model.

Surface Photooxidation of Poly(butylene terephthalate) Films by UV/Ozone Irradiation (자외선/오존 조사에 의한 Poly(butylene terephthalate) 필름의 표면 광산화)

  • Joo, Jin-Woo;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.28 no.2
    • /
    • pp.63-69
    • /
    • 2016
  • Poly(butylene terephthalate)(PBT) surface was modified by UV/ozone irradiation and the effect of UV energy on the surface properties of the irradiated PBT films were characterized by the reflectance, surface roughness, contact angles, ESCA, and ATR analyses of the film surface. The surface reflectance, at the short wavelength of visible spectrum of particularly 400nm, decreased with increasing UV energy. And the irradiation roughened the film surface uniformly in the nano scale. The maximum surface roughness increased from 110nm for the unirradiated sample to 303nm at the UV energy of $10.6J/cm^2$. The surface energy of PBT film increased from $50.5mJ/m^2$ for the unirradiated PBT to $58.8mJ/m^2$ at the irradiation of $21.2J/cm^2$. The improvement in hydrophilicity was caused by the introduction of polar groups containing oxygens such as C-O and C=O bonds resulting in higher $O_{1s}/C_{1s}$. The increased dyeability of the modified film to cationic dyes may be resulted from the photochemically introduced anionic and dipolar dyeing sites on the PBT films surfaces.

A Legal Alternative for Effective Application of Pressurized Smoke Control System to Provide ′Smoke-free′ Access for Escape Shafts Used in High-Rise Building (국내 고층건물의 피난성능확보를 위한 급기가압방연(제연) 시스템의 제도개선연구)

  • 박형주;김상욱
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.49-56
    • /
    • 2001
  • There have been the current controversy over effectiveness of the pressurized smoke control systems, which are installed within escape shaft to provide 'smoke-free' access for escaping peoples. Therefore, many effective measures were given in this paper by means of the production of a design guide for various types of escape routes used in domestic buildings. The solutions were established on basis of both an investigating current door closing device application in existing facilities and global standardization for pressurized smoke control system, especially in British Standard. Finally, the design guidance for open door air velocity with introduction to three door protection clauses was presented on the basis of consideration of the safety and economical factor,

  • PDF

A Study of on the Case Study of LCC Analysis for the Education and Research Building of S University (S대학교 교육연구동 LCC분석 사례 연구)

  • Seo Min-Gu;Ha Han-Ki;Park Tae-Keun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.329-332
    • /
    • 2003
  • The Ministry of Construction and Transportation has estimated the reconsideration of economy in construction and the dullness of LCC forcast method which supports decision-marking in safety and maintenance of buildings. So, they have introduced LCC analysis method in steps of a feasibility study and design. Because of the introduction of LCC analysis process and method, it would be possible to make a logical decision from management maintenance, estimation, user point of view. In this study, it would bepossible to show a plan and alternative of design factors and structure in one building by using LCC analysis method and to compare and analyze the reduction of life circle cost bi the elapsed time.

  • PDF

Numerical calculation of torque converter flow using interrow mixing model (익렬간 혼합모델을 이용한 토크 컨버터 유동장의 수치계산)

  • Park, Jae-In;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.326-335
    • /
    • 1998
  • In this study, a steady three-dimensional incompressible turbulent flow within a torque converter was numerically analyzed with the introduction of interrow mixing model. Mixing planes were introduced to exchange the flow informations between two adjacent elements of the torque converter. The mixing planes were installed among three elements of the torque converter. Therefore, in the present method, it could be possible to calculate the flow-filed within the torque converter without any assumption of circulating flow rates or any extension of boundaries toward the upstream and the downstream for each element. The numerically calculated performances of the torque converter were in good agreement with experimental results, and the complex flow patterns were be observed according to design and off-design condition. As a conclusion, it was found that the present numerical method was very effective in the steady flow analysis of torque converters.

Shake-table tests on moment-resisting frames by introducing engineered cementitious composite in plastic hinge length

  • Khan, Fasih A.;Khan, Sajjad W.;Shahzada, Khan;Ahmad, Naveed;Rizwan, Muhammad;Fahim, Muhammad;Rashid, Muhammad
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.23-34
    • /
    • 2022
  • This paper presents experimental studies on reinforced concrete moment resisting frames that have engineered cementitious composite (ECC) in plastic hinge length (PHL) of beam/column members and beam-column joints. A two-story frame structure reduced by a 1:3 scale was further tested through a shake-table (seismic simulator) using multiple levels of simulated earthquake motions. One model conformed to all the ACI-318 requirements for IMRF, whereas the second model used lower-strength concrete in the beam/column members outside PHL. The acceleration time history of the 1994 Northridge earthquake was selected and scaled to multiple levels for shake-table testing. This study reports the observed damage mechanism, lateral strength-displacement capacity curve, and the computed response parameters for each model. The tests verified that nonlinearity remained confined to beam/column ends, i.e., member joint interface. Calculated response modification factors were 11.6 and 9.6 for the code-conforming and concrete strength deficient models. Results show that the RC-ECC frame's performance in design-based and maximum considered earthquakes; without exceeding maximum permissible drift under design-base earthquake motions and not triggering any unstable mode of damage/failure under maximum considered earthquakes. This research also indicates that the introduction of ECC in PHL of the beam/column members' detailing may be relaxed for the IMRF structures.

A study on classification of the security controls for the effective implementation to nuclear power plant

  • Han, Sang Min;Lee, Chanyoung;Chae, Young Ho;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1245-1252
    • /
    • 2022
  • As regulatory bodies require full implementation of security controls in nuclear power plants (NPPs), security functions for critical digital assets are currently being developed. For the ultimate introduction of security controls, not alternative measures, it is important to understand the relationship between possible cyber threats to NPPs and security controls to prevent them. To address the effectiveness of the security control implementation, this study investigated the types of cyber threats that can be prevented when the security controls are implemented through the mapping of the reorganized security controls in RS-015 to cyber threats on NPPs. Through this work, the cyber threat that each security control can prevent was confirmed, and the effectiveness of several strategies for implementing the security controls were compared. This study will be a useful reference for utilities or researchers who cannot use design basis threat (DBT) directly and be helpful when introducing security controls to NPPs that do not have actual security functions.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

Mitigation of wind-induced vibrations of bridge hangers using tuned mass dampers with eddy current damping

  • Niu, Huawei;Chen, Zhengqing;Hua, Xugang;Zhang, Wei
    • Smart Structures and Systems
    • /
    • v.22 no.6
    • /
    • pp.727-741
    • /
    • 2018
  • To mitigate vibrations, tuned mass dampers(TMD) are widely used for long span bridges or high-rise buildings. Due to some durability concerns, such as fluid degradation, oil leakage, etc., the alternative solutions, such as the non-contacted eddy current damping (ECD), are proposed for mechanical devices in small scales. In the present study, a new eddy current damping TMD (ECD-TMD) is proposed and developed for large scale civil infrastructure applications. Starting from parametric study on finite element analysis of the ECD-TMD, the new design is enhanced via using the permanent magnets to eliminate the power need and a combination of a copper plate and a steel plate to improve the energy dissipation efficiency. Additional special design includes installation of two permanent magnets at the same side above the copper plate to easily adjust the gap as well as the damping. In a case study, the proposed ECD-TMD is demonstrated in the application of a steel arch bridge to mitigate the wind-induced vibrations of the flexible hangers. After a brief introduction of the configuration and the installation process for the damper, the mitigation effects are measured for the ambient vibration and forced vibration scenarios. The results show that the damping ratios increase to 3% for the weak axis after the installation of the ECD-TMDs and the maximum vibration amplitudes can be reduced by 60%.