전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구 (COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY)

  • 강미애;박태원
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

구내 촬영용 방사선 장치의 촬영조건에 따른 선량변화 분석 (Analysis of Condition Changing on Dose Variation using Intraoral Radiation Devices)

  • 김영재;이용탁;송현철
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.137-142
    • /
    • 2012
  • 본 연구는 구강 내 방사선 촬영 시 동일조건 하에서 촬영장비의 기종을 다르게 한 경우와 동일 기종에서 노출조건을 일정하게 하였을 경우 획득되는 방사선의 선량변화를 알아보고자 하였다. 장비의 기종에 따른 변화를 알아보기 위해 3대의 각기 다른 촬영 장치를 이용하여 상악 전치부, 소구치부, 대구치부의 3가지의 촬영조건을 이용하여 선량을 측정하였고 장치의 재현성 검사를 위해서 각 장치에 동일한 조건으로 3회 조사하여 선량변화를 알아보았다. 선량의 측정은 반도체 측정기를 사용하였으며, 필름의 농도값을 획득하여 진단에 유효적인 범위에 만족하는지 분석해 보았다. 같은 촬영기를 사용하여 실험한 결과 각 부위별로 선량의 차이는 최대값과 최소값이 적게는 3배 많게는 10배의 선량 차이를 보였다. 흑화도의 범위 또한 적절한 범위인 0.25~2.0를 초과한 2.10~2.95의 허용범위를 보였다. 동일한 촬영기로 특정 부위를 같은 조건에서 촬영하더라도 측정된 선량값은 큰 차이를 보였으며 필름의 농도 분석의 결과 적합한 농도 분포를 보이지 않았던 것으로 나타났다. 이는 환자의 재촬영을 발생시킬 수 있으며 진단시 오류를 일으킬 수 있어 환자의 피폭에 직 간접적인 피해를 일으킬 수 있다. 따라서 치과 방사선 촬영장치 또한 정기점검이 필요할 것으로 생각되며 표준화된 촬영조건과 현상조건이 제공되어야 한다고 사료된다.

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Screening panoramic radiographs in a group of patients visiting a Health Promotion Center

  • Lee Jae-Seo;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.199-202
    • /
    • 2005
  • Purpose : To report the incidence of radiological findings from screening panoramic radiographs and verify the validity of the panoramic radiography for screening purposes. Materials and Methods : Six thousand one hundred and sixty panoramic radiographs taken from the patients visiting the Health Promotion Center of CNUH were selected for this retrospective study. Panoramic radiographs were examined into the following pathologic conditions : the presence of periodontal bone loss, dental caries, periapical radiolucencies, retained roots, impacted supernumerary teeth, impacted third molars, odontoma, cystic lesions other than radicular cyst, sialoliths, and mixed radiolucent-radiopaque lesions. Number of pathologic conditions and Prevalence values were recorded. Results: The prevalences of pathologic conditions were $72.9\%$ of periodontal bone loss, $32.2\%$ of dental caries, $11.9\%$ of periapical radiolucencies, $10.8\%$ of retained roots, $0.4\%$ of root fracture, $1.0\%$ of impacted supernumerary teeth, $1.0\%$ of impacted third molars, $0.06\%$ of odontoma, $0.08\%$ of cystic lesion other than radicular cyst, $0.2\%$ of prolonged retention of deciduous tooth, $0.1\%$ of sialolith, and $0.04\%$ of mixed radiopaque and radiolucent lesion. Conclusion : Although the panoramic radiograph should not be used to replace intraoral radiographic and clinical examinations, this study showed that many dental pathologic conditions could be detected on panoramic radiographs. The panoramic radiograph might serve as a diagnostic aid in dental health evaluation programs.

  • PDF

심층학습 알고리즘을 활용한 인접면 우식 탐지 (Detection of Proximal Caries Lesions with Deep Learning Algorithm)

  • 김현태;송지수;신터전;현홍근;김정욱;장기택;김영재
    • 대한소아치과학회지
    • /
    • 제49권2호
    • /
    • pp.131-139
    • /
    • 2022
  • 이번 연구는 소아의 인접면 우식을 진단하는데 있어 사용하고 있는 구내방사선 사진에서 심층학습(deep learning) 알고리즘을 활용하여 치아우식을 진단하는 모델의 성능을 평가하고자 하였다. 제1유구치와 제2유구치 사이의 인접면이 포함된 500개의 구내방사선 사진을 대상으로 연구를 시행하였다. 치아우식을 진단하는 모델의 학습에는 Resnet50 기반의 인공신경망 모델을 사용하였다. 평가자료군에서 진단모델의 정확도, 민감도, 특이도를 구하고, ROC 곡선을 얻어 AUC 값을 바탕으로 분류 모델의 성능을 평가하였다. 학습 모델의 정확도는 0.84, 민감도는 0.74, 특이도는 0.94로 나타났으며 AUC는 0.86으로 나타났다. 인공신경망을 기반으로 하는 소아의 구내방사선 사진에서의 인접면 우식의 진단 모델은 비교적 높은 정확도를 보여주었다. 심층학습 모델은 구내방사선 사진상에서 인접면 우식을 진단하는데 있어 향후 치과의사를 보조하는 진단 도구로서 활용될 수 있을 것이다.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

근관장 측정시 구내 디지털 방사선 시스템인 Digora System의 정확도에 관한 연구 (THE ACCURACY OF DIGORA SYSTEM, AN INDIRECT DIGITAL RADIOGRAPHIC SYSTEM, IN DETERMINING THE WORKING LENGTH)

  • 한상욱;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.347-357
    • /
    • 1997
  • An accurate working length is an essential factor in the success of endodontic treatment. There are several methods for determining working length; electronic apex locator, tactile sense by clinician, and radiography. Among these methods, the most commonly used method is radiography. But this method requires excessive radiation, long developing time, and many equipments. In additon, it could give an image distortion and two dimensional image. To improve these disadvantages, an intraoral digital radiographic system (Digora$^{(R)}$) which use an imaging plate instead of a film, was developed. The purpose of this investigation was to compare Digora imaging with conventional radiography in determining the working length. Maxillary first or second molars of human dried skull were used. Files were inserted into canals at randomly selected lengths, from 2mm short of the radiographic apex to 2rnm beyond. Radiographs and Digora images(Digora positive and Digora negative) were evaluated to determine the adjustment needed to place the file 0.5mm from the radiographic apex. The results were as follows ; 1. There was no significant difference in accuracy between those evaluated in ${\pm}0.5mm$ and those accurately evaluated in the 3 images. 2. When comparing the accuracy of each image without distinguishing the 3 images, in the group accurately determined within ${\pm}0.5mm$, the mesiobuccal group showed significantly higher accuracy compared to the palatal group(p<0.05).

  • PDF

The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

  • Miri, Shimasadat;Mehralizadeh, Sandra;Sadri, Donya;Motamedi, Mahmood Reza Kalantar;Soltani, Parisa
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.141-145
    • /
    • 2015
  • Purpose: This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods: Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections $5{\mu}m$ in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (${\alpha}=0.05$). Results: Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion: The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy.

Deep learning convolutional neural network algorithms for the early detection and diagnosis of dental caries on periapical radiographs: A systematic review

  • Musri, Nabilla;Christie, Brenda;Ichwan, Solachuddin Jauhari Arief;Cahyanto, Arief
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.237-242
    • /
    • 2021
  • Purpose: The aim of this study was to analyse and review deep learning convolutional neural networks for detecting and diagnosing early-stage dental caries on periapical radiographs. Materials and Methods: In order to conduct this review, the Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA) guidelines were followed. Studies published from 2015 to 2021 under the keywords(deep convolutional neural network) AND (caries), (deep learning caries) AND (convolutional neural network) AND (caries) were systematically reviewed. Results: When dental caries is improperly diagnosed, the lesion may eventually invade the enamel, dentin, and pulp tissue, leading to loss of tooth function. Rapid and precise detection and diagnosis are vital for implementing appropriate prevention and treatment of dental caries. Radiography and intraoral images are considered to play a vital role in detecting dental caries; nevertheless, studies have shown that 20% of suspicious areas are mistakenly diagnosed as dental caries using this technique; hence, diagnosis via radiography alone without an objective assessment is inaccurate. Identifying caries with a deep convolutional neural network-based detector enables the operator to distinguish changes in the location and morphological features of dental caries lesions. Deep learning algorithms have broader and more profound layers and are continually being developed, remarkably enhancing their precision in detecting and segmenting objects. Conclusion: Clinical applications of deep learning convolutional neural networks in the dental field have shown significant accuracy in detecting and diagnosing dental caries, and these models hold promise in supporting dental practitioners to improve patient outcomes.