• Title/Summary/Keyword: intracoronary stenting

Search Result 7, Processing Time 0.022 seconds

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF

Comparison of Clopidogrel versus Cilostazol in Coronary Artery Stenting (관상동맥 스텐트 삽입술 후 Clopidogrel과 Cilostazol의 비교)

  • Song, In-Sook;Choi, Seung-Ki;Oh, Jung-Mi
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.2
    • /
    • pp.105-117
    • /
    • 2005
  • Following intracoronary stenting, antiplatelet therapy lead to greater protection from thrombotic complication. A few data are available about the effect of clopidogrel versus cilostazol, an antiplatelet commonly used after intracoronary stenting. To evaluate the efficacy and safety of clopidogrel plus aspirin compared with those of cilostazol plus aspirin in coronary stenting and to evaluate the efficacy of clopidogrel loading dose prior to coronary stealing in clopidogrel group. Data were retrospectively collected from medical charts of patients who had undergone coronary stenting and received either clopidogrel with or without loading 300 mg followed by 75 mg/d (n=58), or 200 mg/d cilostazol(n=72) for 1 year, between January 2000 and May 2002. All patients in both groups received aspirin 200 mg/d throughout the study. The primary endpoints at 7, 30, 180 and 365 days after stealing were the composite of death, Myocardial Infarction, stroke, angina, and revascularization in the intent to treat population and restenosis at follow up angiography. The secondary endpoints were the incidence of bleeding complications at 7, 30, and 365 days, and durg adverse effects at 365 days after stenting. At 180 and 365 days after stenting, the combined primary endpoints were significantly reduced in clopidogrel plus aspirin group (relative risk 0.39; 95% CI 0.17 to 0.92; p=0.021, RR 0.43; 95% CI 0.22 to 0.84; p=0.0085, respectively). However, the combined primary endpoints were not significantly different between the two groups at 7 and 30 days (p:1.00, p=0.79, respectively). Angiographic restenosis rate was 14.3% in clopidogrel plus aspirin uoup and 32.1% in cilostazol plus aspirin group (p=0.19). 300mg of clopidogrel loading dose did not significantly reduce the combined primary endpoints at 30 days after stenting (RR 0.14; 95% CI 0.01 to 2.65; p=0.23). The rate of bleeding complications and drug adverse effects were not different between the two groups. In patients undergoing intracoronary stenting, clopidogrel plus aspirin therapy is more beneficial than cilostazol plus aspirin in reducing major adverse cardiac events with similar rate of bleeding complication. A loading dose of clopidogrel did not lead to a statistically significant reduction in major adverse cardiac events.

  • PDF

Changes of Hemodynamic Characteristics during Angulated Stenting in the Stenosed Coronary (관상동맥 협착부에 각이진 스텐트 시술시 혈류역학적 특성변화)

  • Suh Sang-Ho;Cho Min-Tae;Kwon Hyuck-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.717-720
    • /
    • 2002
  • The present study is to evaluate the performances of flow velocity and wall shear stress in the stenosed coronary artery using human in vivo hemodynamic Parameters and computer simulation. Initial and follow-up coronary angiographics in the patients with angulated coronary stenosis are performed. Follow-up coronary angiogram demonstrated significant difference in the percent of diameter in the stenosed coronary between two groups ($Group\;1:\;40.3{\%},\;Group\;2:\;25.5{\%}$). Flow-velocity wave obtained from in vivo intracoronary Doppler ultrasound data is used for the boundary condition for the computer simulation. Spatial and temporal variations of flow velocity vector and recirculation area are drawn throughout the selected segment of coronary models. The WSS of pre- and post-intracoronary stenting are calculated from three-dimensional computer simulation. Then negative shear stresses area on 3D simulation we noted on the inner wall of the post-stenotic area before stenting. The negative WSS is disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2. The present study suggest that hemodynamic forces exerted by pulsatile coronary circulation termed WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. The local recirculation area which has low or negative WSS, might lead to progression of atherosclerosis.

  • PDF

Intracoronary Radiation Therapy (관동맥혈관 내 방사선 근접 치료)

  • Moon, Dae-Hyuk;Park, Seong-Wook;Hong, Myeong-Ki;Oh, Seung-Jun;Bom, Hee-Seung;Lee, Hee-Kyung
    • 대한핵의학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.24-34
    • /
    • 2001
  • Restenosis remains a major limitation of percutaneous coronary interventions. Numerous studios including pharmacological approaches and new devices failed to reduce the restenosis rate except coronary stenting. Since the results of $BENESTENT^{1)}\;and\;STRESS^{2)}$ studies came out, coronary stenting has been the most popular interventional strategy in the various kinds of coronary stenotic lesions, although the efficacy of stenting was shown only in the discrete lesion of the large coronary artery. The widespread use of coronary stenting has improved the early and late outcomes after coronary intervention, but it has also led to a new and serious problem, e.g., in-stent restenosis. Intravascular radiation for prevention of restenosis is a new technology in the field of percutaneous coronary intervention. Recent animal experiments and human trials have demonstrated that local irradiation, in conjunction with coronary interventions, substantially diminished the rate of restenosis. This paper reviews basic radiation biology of intracoronary radiation and its role in the inhibition of restenosis. The current status of intracoronary radiation therapy using Re-188 liquid balloon is also discussed.

  • PDF

Effects of Stenting Shapes on the Wall Shear Stress in the Angulated Coronary Stenosis (협착된 관상동맥에 시술된 스텐트형상이 벽면 전단응력에 미치는 영향)

  • Cho, Min-Tae;Suh, Sang-Ho;Yoo, Sang-Sin;Keun, Huk-Moon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.219-222
    • /
    • 2001
  • The objective of the present study is to evaluate the effects of the stenting shapes on flow velocity and wall shear stress in angulated coronary stenosis by computer simulation. Coronary angiogram and Doppler ultrasound measurement in the patients with angulated coronary stenosis were obtained. Inlet wave velocity distribution obtained from in vivo intracoronary Doppler data was used for the numerical simulation. Spatial pattern of blood flow velocity and recirculation area were drawn through out the selected segment of coronary models. Wall shear stresses in the intracoronary stent models were calculated from three-dimensional computer simulation. A negative shear stress region, which is consistent with re-circulation area on flow pattern, was noted on the inner wall of post-stenotic area of pre-stenting model. The negative shear stress was disappeared after stenting. Shear stress in the post-stenting model was markedly reduced up to about two orders of magnitude compared to that of the pre-stenting model.

  • PDF

Combined Percutaneous Transluminal Coronary Angioplasty and Minimally Invasive Coronary Arterial Bypass Grafting(Hybrid CABG) (경피적 경혈관 관상동맥 중재술과 최소침습성 관상동맥 우회술의 병용요법)

  • 장지민;유원희;김기봉
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1127-1130
    • /
    • 1999
  • Percutaneous coronary intervention including intracoronary stenting is currently an accepted treatment modality in the treatment of coronary artery disease and is widely performed to treat the patient with multivessel disease with decreased morbidities and less cost compared with conventional coronary rtery bypass grafting(CABG), Repeated interventions due to restenosis even after successful angioplasty are the major disadvantage of the angioplsty especially when the lesion is located inthe left anterior descending artery(LAD) Recently CABG through left anterior small thoracotomy using the left internal thoracic artery to revascularize the LAD territory without cardiopulmonary bypass so called Minimally Invasive Direct Coronary Artery Bypass(MIDCAB) was intrduced and performed with comparable early outcomes. In this regard the integrated approach with percutaneous coronary intervention and minimally invasive direct coronary artery bypass surgery so called 'Hybrid CABG' was suggested to be an effective treatment in suitable patients with multivessel coronary artery disease. We report three cases of Hybrid CABG.

  • PDF

Cardiac Intracoronary Stenting vs CABG: Prevention of Medical Accident (심장 스텐트 시술과 의료사고 예방)

  • Kim, Kyoung Reay;Park, Kook Yang
    • The Korean Society of Law and Medicine
    • /
    • v.18 no.2
    • /
    • pp.163-194
    • /
    • 2017
  • Coronary artery disease has increased in Korea as the country enters the aged society. It is well known that the incidence of coronary artery disease is related to aging, hypertension, diabetes, hyperlipidemia, and dietary habit. For effective treatment of significant coronary stenosis, close coordination between cardiac surgery and cardiology team is essential. Especially cardiologists' decision whether to do the stent placement or CABG is very important because the cardiologists usually start to consult the patients for their treatment. Recently, non-surgical interventions(that is stent placement) in cardiology field have dramatically increased as the national insurance system removed the limitation of the number of stents deployed. However, accidents are often caused by inappropriate use of stents, especially in patients with triple coronary disease or left main disease with heavy coronary calcifications. Another aspect of stent placement is to cope with an emergency case in the event of coronary rupture or pericardial tamponade during coronary interventions without cardiac surgeons. In the past two years, the Korea Consumer Agency (Consumer Dispute Coordination Committee) analyzed eight cases of medical dispute settlement. Only two hospitals were manned with both cardiologists and cardiac surgeons. Seven patients died of procedures of stenting and five patients died on the day of the procedure. Among the 8 cases, 5 cases showed 3 vessel disease and the rest of the cases had either severe calcification, complete occlusion or poor coronary antomies for stenting According to a 2017 national data registry of coronary stenting, less than 3 drug-eluting stents were implanted in 98% of all patients. In 2015, the number of stent procedures was 38,922, and approximately in 800 (2%) cases, more than four stents were used per patient. We emphasize that it is necessary to seriously consider the cost-benefit analysis between stent and CABG. The patient has the right to choose the right procedure by asking the liability of 'instruction explanation obligation'. He should be well informed of the pros and cons of both procedures to avoid overuse of stent. It can be solved by intimate discussion of individual cases with the cardiac surgeon and the patient. Unilateral dialogue with the patient, forceful restriction on the number of stenting, lack of surgeon's backup in difficult cases should all be avoided. It is also necessary to solve the problem not only at the hospital level, such as multidisciplinary integrated medical care, but also a nationwide solution such as expanding cardiac surgeons as essential personnel to public officials.

  • PDF