• 제목/요약/키워드: intracavitary brachytherapy

검색결과 55건 처리시간 0.026초

자궁 경부암 고선량율 강내조사 치료의 국내 현황과 적정 치료방법 (Current Status of High Dose Rate Brachytherapy in Cervical Cancer in Korea and Optimal Treatment Schedule)

  • 허승재
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.357-366
    • /
    • 1998
  • Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week. 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4.1 Gy each to Point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as. 78-86$\%$ for Stage 1, 68-85$\%$ for stage 11, and 38-56$\%$ for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In addition, standardization of HDR application (clinical, computer algorithms, and dosimetric aspects) is necessary.

  • PDF

High Dose Rate Brachytherapy in Two 9 Gy Fractions in the Treatment of Locally Advanced Cervical Cancer - a South Indian Institutional Experience

  • Ghosh, Saptarshi;Rao, Pamidimukkala Bramhananda;Kotne, Sivasankar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7167-7170
    • /
    • 2015
  • Background: Although 3D image based brachytherapy is currently the standard of treatment in cervical cancer, most of the centres in developing countries still practice orthogonal intracavitary brachytherapy due to financial constraints. The quest for optimum dose and fractionation schedule in high dose rate (HDR) intracavitary brachytherapy (ICBT) is still ongoing. While the American Brachytherapy Society recommends four to eight fractions of each less than 7.5 Gy, there are some studies demonstrating similar efficacy and comparable toxicity with higher doses per fraction. Objective: To assess the treatment efficacy and late complications of HDR ICBT with 9 Gy per fraction in two fractions. Materials and Methods: This is a prospective institutional study in Southern India carried on from $1^{st}$ June 2012 to $31^{st}$ July 2014. In this period, 76 patients of cervical cancer satisfying our inclusion criteria were treated with concurrent chemo-radiation following ICBT with 9 Gy per fraction in two fractions, five to seven days apart. Results: The median follow-up period in the study was 24 months (range 10.6 - 31.2 months). The 2 year actuarial local control rate, disease-free survival and overall survival were 88.1%, 84.2% and 81.8% respectively. Although 38.2% patients suffered from late toxicity, only 3 patients had grade III late toxicity. Conclusions: In our experience, HDR brachytherapy with 9 Gy per fraction in two fractions is an effective dose fractionation for the treatment of cervical cancer with acceptable toxicity.

자궁경부암 고선량율 강내치료의 치료선량 정확도에 관한 연구 (Accuracy of Dose Estimation in High Dose Rate Intracavitary Radiotherapy of Carcinoma of the Uterine Cervix)

  • 허승재;하성환;채규영
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.137-140
    • /
    • 1987
  • 자궁경부암의 고선량율 강내치료의 매 분할 치료시마다 강내 applicator의 위치 차이로 인하여 조사 선량이 치료전 계획된 선량과 차이가 있을 수 있다. 저자는 자궁경부암 환자의 강내치료시 치료전 계획된 A점 선량 500 cGy와 치료직후에 촬영한 전후 및 측면 선 사진을 이용하여 계산된 A점 선량을 비교한 결과, 82예의 강내치료에서 치료 후 계산된 조사 선량과 계획 선량은 $500\pm18 cGy$이었으며 $84\%$에서 $500\pm25 cGy$의 범위에 포함되었다. 이러한 결과에서 계획 선량과 치료 후 계산된 조사 선량사이에 비교적 높은 일치율을 확인할 수 있었다.

  • PDF

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.

Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획 (Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer)

  • 허승재;강위생
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.183-186
    • /
    • 1986
  • 고선량율을 이용한 자궁강내 치료시 정확하고 신속한 계산을 위하여 저자들은 개인용 컴퓨터를 이용하여 기준점의 선량분포 및 방사선조사 시간을 간편하게 계산할 수 있는 software를 개발하였다. 치료 계획용 software를 이용하여 짧은 시간내에 선량 분포 및 조사시간을 용이하고 정확하게 계산할 수 있으며, 고선량을 자궁경부암 임상적응에 효과적으로 이용할 수 있어서 보고한다.

  • PDF

강내온열 치료를 위한 원통형 초음파 치료기 개발 (Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia)

  • Lee, Rena J.;Hyunsuk Suh
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2002
  • 항문암 및 자궁경부암 치료시 사용되는 고선량률 강내 근접치료기와 병행하여 사용할 원통형 초음파 온열치료가 개발되었다. 온열치료를 위한 에너지원으로 원통형 트랜스듀서가(PZT-8 물질, 길이=1.5 cm 두께=1.5 mm 외경= 2.5cm) 사용되었다. PZT-8 물질의 특성을 측정하기위해 세 개의 단일 엘리멘트 어플리케이터가 제작되었다. PZT 물질을 작동하기 위한 주파수를 결정하기 위하여 벡터 임피던스가 측정되었다. 선택된 물질이 온열치료에 사용될 수 있는지 가능성을 타진하기위해 방사능력을 측정하는 방법으로 각 엘리맨트의 초음파발생 효율을 입력한 전기량과 발생한 초음파량의 비로 계산하였다. 마지막으로 질암의 온열치료에 사용할 수 있는 다채널 초음파 치료기가 디자인 되었다. 임피던스 실험결과 각 엘리맨트 1, 2, 그리고 3에 대해 1.78, 1.77, 그리고 1.77 MHz의 주파수에서 최대 임피더스 값을 얻었다. 방사능력 측정 실험결과 본 연구에서 사용된 에너지 소스는 40와트 이상의 초음파량이 방출되었다. 또한 각 엘리맨트 1, 2, 그리고 3의 평균 효율은 61.4, 65.2, 그리고 54.0% 이다. 본 연구에서 디자인되어진 원통형 초음파 치료기는 질 또는 항문 치료 시 고선량 강내근접치료와 더불어 사용할 수 있음이 증명되었다. 따라서 본 연구에서 개발된 온열 치료기구가 고 선량 강내 근접치료와 함께 사용하여 병변조직의 방사능 민감도를 증가시켜 암 치료효율을 높일수 있다.

  • PDF

Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

  • Choi, Euncheol;Kim, Jae Ho;Kim, Ok Bae;Byun, Sang Jun;Kim, Jin Hee;Oh, Young Kee
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.227-234
    • /
    • 2018
  • Purpose: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. Materials and Methods: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses of the actual 3D and 2D ICBT plans among patients grouped according to six anatomical variations: differences in a small-bowel V2Gy, small bowel circumference, the direction of bladder distension, bladder volume, sigmoid V3.5Gy, and sigmoid circumference. Seven dose parameters were measured in line with the EMBRACE recommendations. Results: In terms of bladder volume, the bladder and small-bowel D2cc values were lower in the 150-250 mL bladder volume subgroup; and the rectum, sigmoid, and bladder D2mL values were all lower in the >250 mL subgroup, for 3D vs. 2D ICBT. In the sigmoid V3.5Gy >2 mL subgroup, the sigmoid and bladder D2mL values were significantly lower for 3D than 2D ICBT. The bladder D2mL value was also significantly lower for 3D ICBT, as reflected by the sigmoid circumference. In patients with a small bowel V2.0Gy >10 mL or small bowel circumference >15%, most dose parameters were significantly lower for 3D than 2D ICBT. The bladder distension direction did not significantly affect the doses. Conclusion: Compared to 2D ICBT, a greater bladder volume can reduce the internal 3D ICBT organ dose without affecting the target dose.

고선량율 질강 근접조사를 위한 새로운 적용구의 제작 (Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy)

  • 신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제17권2호
    • /
    • pp.123-128
    • /
    • 2000
  • 본 연구에서 인체공학적으로 개선된 새로운 2-채널 고선량을 근접치료용 적용구(Shin's Applicator)를 개발하였으며, 기존의 단일 선원 근접치료 적용구와 비교하여 질벽에 더 균등한 방사선치료가 가능하고 방광과 직장선량이 적어 근접치료 후 발생할 수 있는 부작용이 감소될 가능성을 확인하였다. 임상적으로 Shin's Applicator는 자궁 경부암이나 자궁 체부암의 수술 후 국소재발이나, 절강에 발생한 다발설 악성종양을 효과적으로 치료하는 데 유용하게 사용될 수 있을 뿐 만 아니라, 방사선 치료 후 흔히 나타나는 질강의 협착을 예방할 수 있는 질 확장기(vaginal dilator)로도 사용 가능하였다. 이상의 결과에서 Shin's Applicator는 부인과 종양환자들의 방사선치료 뿐만 아니라 치료 후 삶의 질의 개선에도 크게 기여할 것으로 생각되었다.

  • PDF