• Title/Summary/Keyword: interval scanning

Search Result 103, Processing Time 0.033 seconds

Caption Detection and Recognition for Video Image Information Retrieval (비디오 영상 정보 검색을 위한 문자 추출 및 인식)

  • 구건서
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.7
    • /
    • pp.901-914
    • /
    • 2002
  • In this paper, We propose an efficient automatic caption detection and location method, caption recognition using FE-MCBP(Feature Extraction based Multichained BackPropagation) neural network for content based retrieval of video. Frames are selected at fixed time interval from video and key frames are selected by gray scale histogram method. for each key frames, segmentation is performed and caption lines are detected using line scan method. lastly each characters are separated. This research improves speed and efficiency by color segmentation using local maximum analysis method before line scanning. Caption detection is a first stage of multimedia database organization and detected captions are used as input of text recognition system. Recognized captions can be searched by content based retrieval method.

  • PDF

Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline (단열배관의 온라인 두께측정시스템 개발)

  • Jang, Ji-Hun;Kim, Byeong-Ju;Jo, Gyeong-Sik;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.32
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF

Clinical Experience of Management of Lower Leg Pain due to Chloroma of Lumbosacral Bone in Chronic Myelogenous Leukemia (만성골수성 백혈병 환자에서 발생한 요천추부 Chloroma로 인한 좌하지통증의 치료경험 1예 보고)

  • Sung, Choon-Ho;Chung, Woon-Hyok
    • The Korean Journal of Pain
    • /
    • v.2 no.1
    • /
    • pp.61-65
    • /
    • 1989
  • Chloroma is a localized myeloblastic tumor which may develop during the course of myelogenous leukemia or as a presenting sign of the disease. A 47-year-old female diagnosed as chronic myelogenous leukemia in her hematologic remission period complained of left lower leg pain. The lumbar-spine series showed multiple osteolytic changes in the left lateral border of the lumbar spine. An inhomogenous soft tissue mass involving left lateral aspects of lumbar vertebrae was identified by CT-scanning. At the first pain attack, lumbar epidural steroid and local anesthetic injection could abolish her pain and the patient could go a few days without pain. The following radiation therapy could also improve the symptom and retain the pain free interval. One month later, a second pain attack occurred and lumbar and caudal epidural steroid and local anesthetic injections could result only in an incidental relief of pain. Radiation and chemotherapy were started but failed to relieve pain. A neurolytic block was considered but the patient's general condition was aggravated and even verbal communication with her became impossible.

  • PDF

A New Driving Method for Gray-scale Expression in an AC Plasma Display Panel (교류형 플라즈마 디스플레이 패널에서 계조표현을 위한 새로운 구동방식)

  • 김재성;황현태;서정현;이석현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.407-414
    • /
    • 2004
  • In this paper, a new gray scale expression method that divides the scan lines into multiple blocks is suggested. The proposed method can drive 16 sub-fields per 1 TV field in the panel with XGA ($1366{\times}768$) resolution. The on and off states of even subfields depend on the condition of odd subfields. The write address mode is used in the odd subfields, while the erase address mode is used in the even subfields. Because the ramp reset pulse is applied every 2 sub-fields, both the contrast ratio and the dynamic voltage margin are sufficiently obtained in comparison with previous AWD (Address While Display) methods. In realizing 16 subfields, shortening the scan time in the erase address period was important. The X bias voltage in the erase address period affected the minimum address voltage but did not the delay time of the address discharge. The delay time of the address discharge was affected by the address voltage and the time interval between the last sustain discharge and the scanning time. We also evaluated the dynamic false contour. New method shows an improved image quality in horizontal moving, but discontinuous lines were observed at the boundaries of each block in vertical moving

Digital Scan Converter Algorithm for Ultrsound Sector Scanner (초음파 섹터 스캐너를 위한 디지털 스캔 변환 기법)

  • 김근호;오정환
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.469-478
    • /
    • 1996
  • In the conventional digital ultrasound scanner, the reflected signal is sampled either in polar coordinates of R-$\theta$ method, or in Cartesian coordinates of uniform ladder algorithm (ULA). The R-$\theta$ scan method necessitates a coordinate transform process which makes hardware complex in comparison with ULA scan mrthoA In spite of this complexity, R-$\theta$ method has a good resolution in ultrasonographic (US) image, since scan direction of the US imaging is a radial direction. In this paper, a new digital scan converter is proposed, which is named the radius uniform ladder algorithm (RULA). The RULA has the rome scan direction as the US scanning in the radial direction and as the display space in the $\theta$ direction. In tllis new approach, sampled points we uniformly distributed in each horizontal line i.n well as in each radial ray so that the data are displayed in the Cartesian coordinates by the 1-D interpolation process. The propped algorithm has an uniform resolution in the periphery and the center field in comparison with equi-angle ULA and equi-interval ULA. To extend the scan angle, concentric square raster sampling (CSRS) is adopted with reduction of discontinuities on the junctions between horizontal scan and vertical scan. The discontinuities are reduced by using the hmction filtering along the $\theta$ direction.

  • PDF

Improvement of Fatigue Properties in Ferroelectric Dy-Doped Bismuth Titanate(BDT) Thin Films Deposited by Liquid Delivery MOCVD System (Liquid Delivery MOCVD로 증착된 강유전체 BDT 박막의 피로 특성 향상)

  • Kang, Dong-Kyun;Park, Won-Tae;Kim, Byong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.171-171
    • /
    • 2007
  • Dysprosium-doped bismuth titanate (BDT) thin films were successfully deposited on Pt(111)/Ti/$SiO_2$/Si(100) substrates by liquid delivery MOCVD process and their structural and ferroelectric properties were characterized. Fabricated BDT thin films were found to be random orientations, which were confirmed by X-ray diffraction experiment and scanning electron microscope analysis. The crystallinity of the BDT films was improved and the average grain size increased as the crystallization temperature increased from 600 to $720^{\circ}C$ at an interval of $40^{\circ}C$. The BDT thin film annealed at $720^{\circ}C$ showed a large remanent polarization (2Pr) of $52.27\;{\mu}C/cm^2$ at an applied voltage of 5V. The BDT thin film exhibits a good fatigue resistance up to $1.0{\times}10^{11}$ switching cycles at a frequency of 1 MHz with applied pulse of ${\pm}5\;V$. These results indicate that the randomly oriented BDT thin film is a promising candidate among ferroelectric materials useti비 in lead-free nonvolatile ferroelectric random access memory applications.

  • PDF

Effect of granite fines on mechanical and microstructure properties of concrete

  • Jain, Kishan Lal;Sancheti, Gaurav
    • Advances in concrete construction
    • /
    • v.13 no.6
    • /
    • pp.461-470
    • /
    • 2022
  • Solid waste management is of great concern in today's world. An enormous amount of waste is generated from various industrial activities. Concrete production utilizing some of the potential waste materials will add to the benefit of society. These benefits will include reduction of landfill burden, improved air quality, riverbed protection due to excessive sand excavation, economical concrete production and much more. This study aims to utilize waste granite powder (GP) originating from granite industries as a sand replacement in concrete. Fine GP was collected in the form of slurry from different granite cutting industries. In this study, GP was added in an interval of ten percent as 10%, 20%, 30%, 40% and 50% by weight of sand in concrete. Mechanical assets; compressive strength, flexural strength and splitting tensile strength were prominent for control and blended mixes. Modulus of elasticity (MoE) and abrasion tests were also performed on control and blended specimens of concrete. To provide a comprehensive clarification for enhanced performance of GP prepared concrete samples, scanning electron microscopy (SEM) and X-ray diffraction (XRD) were performed. Results indicate that 30% replacement of sand by weight with GP enhances the mechanical assets of concrete and even the results obtained for 50% replacement are also acceptable. Comprehensive analysis through SEM and XRD for 30% replacement was better than control one. The performance of GP added to concrete in terms of abrasion and modulus of elasticity was far better than the control mix. A significant outcome shows the appropriateness of granite fines to produce sustainable and environmentally friendly concrete.

Study On The Signal Radar Plan Position Indicator Scope Of The Data Expressed Scanning System Implemented As An Sticking Image On LCD Display (Plan Position Indicator Scope 주사방식의 Radar 영상신호를 LCD Display에 잔상영상으로 데이터 표출 구현에 관한 연구)

  • Shin, Hyun Jong;Yu, Hyeung Keun
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.94-101
    • /
    • 2015
  • The display device is an important video information communication system device to connect between human and device. it transfers the information as characters, shapes, images and pattern to enable recognizing by eyes. Theres absolutely needs some key functions and role to quickly display informations. It can analyse a information through a PPI Scope of a cathode-ray tube(CRT) displays information which can perform a role. this research proposed a radar device to display informations as received signal. The radar display researches can apply to fixed function graphics pipeline algorithms of the large capacity type through a vertical blanking interval and buffer swap of display unit. Also, it can be possible to apply to performed algorithms to FPGA logic without high-performance graphics processing unit GPU through synchronization which can implement a display system. In this paper, we improved the affordability and reliability through proposed research. 이So, we have studied the radar display unit which can change a flat display from radar display of CRT radar display.

Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography (초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구)

  • Lee, Jong-Seok;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.149-160
    • /
    • 2007
  • Recent advent of 64-multidetctor (MD) CT enables more coverage of Z-axis in the perfusion imaging. The purpose of this study was to evaluate the clinical usefulness of perfusion CT by using 64-MD CT in detecting the lesion in patients with acute stroke. The perfusion CT was performed by using 64-MD CT in 62 consecutive patients who were initially suspected to have subacute ischemic stroke symptoms during the period of recent 9 months. These patients had subacute stroke (n=62). CT scanning was conducted with Jog Mode which provided 16 imaging slices with 5 mm of slice thickness, and 8 cm of coverage in Z-axis. Scan interval was 1 seconds for each imaging slice and total 15 scans were repeated. After CT scanning, perfusion maps (CBV, CBF, MTT and TTP) were created at Extended Brilliance Workstation. The CBV and CBF maps showed that lesions were smaller images. While on the MTT and TTP map lesions were seen to be larger fifty-one were large than they appeared on these images. Two slices of perfusion maps obtained at the level of the basal ganglia were chosen to simulate conventional older perfusion CT with 8 cm of coverage in Z-axis. TTP and MTT maps may be clinically useful for evaluation of the penumbral zone in cases of aubacute cerebral ischemic stroke. The perfusion CT is useful in the assessment of acute stroke as an initial imaging modality.

  • PDF

Formation Mechanism of Pores in Ni-P Coated Carbon Fiber Prepared by Electroless Plating Upon Annealing (무전해 니켈-인 도금법을 이용하여 도금된 탄소 섬유의 열처리 과정에서 나타나는 다공성 구조 생성 메커니즘 분석)

  • Ham, Seung Woo;Sim, Jong Ki;Kim, Young Dok
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.438-442
    • /
    • 2013
  • In the present work, electroless plating was used for coating thin films consisting mainly of Ni and P on carbon fiber. Structural changes appeared upon the post-annealing at various temperatures of the Ni-P film on carbon fiber was studied using various analysis methods. Scanning, a flat surface structure of Ni-P film on carbon fiber was found after electroless plating of Ni-P film on carbon fiber without post-annealing, whereas annealing at $350^{\circ}C$ resulted the formation of porous structures. With increasing the annealing temperature to $650^{\circ}C$ with an interval of $50^{\circ}C$, the pore size increased, but the density decreased. X-ray diffraction (XRD) showed the existence of metallic Ni, and Ni-P compounds before post-annealing, whereas the post-annealing resulted in the appearance of NiO peaks, and the decrease in the intensity of the peak of metallic Ni. Using X-ray photoelectron spectroscopy (XPS), phosphorous oxides were detected on the surface upon annealing at $650^{\circ}C$, and $700^{\circ}C$, which can be attributed to the phosphorous compounds originally existing in the deeper layers of the Ni films, which undergo sublimation and escape from the film upon annealing. Escape of phosphorous species from the bulk of Ni-P film upon annealing could leave a porous structure in the Ni films. Porous materials can be of potential applications in diverse fields due to their interesting physical properties such as high surface area, and methods for fabricating porous Ni films introduced here could be easily applied to a large-scale production, and therefore applicable in diverse fields such as environmental filters.