• Title/Summary/Keyword: interval load

Search Result 282, Processing Time 0.03 seconds

Analysis of a cable-stayed bridge with uncertainties in Young's modulus and load - A fuzzy finite element approach

  • Rama Rao, M.V.;Ramesh Reddy, R.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.3
    • /
    • pp.263-276
    • /
    • 2007
  • This paper presents a fuzzy finite element model for the analysis of structures in the presence of multiple uncertainties. A new methodology to evaluate the cumulative effect of multiple uncertainties on structural response is developed in the present work. This is done by modifying Muhanna's approach for handling single uncertainty. Uncertainty in load and material properties is defined by triangular membership functions with equal spread about the crisp value. Structural response is obtained in terms of fuzzy interval displacements and rotations. The results are further post-processed to obtain interval values of bending moment, shear force and axial forces. Membership functions are constructed to depict the uncertainty in structural response. Sensitivity analysis is performed to evaluate the relative sensitivity of displacements and forces to uncertainty in structural parameters. The present work demonstrates the effectiveness of fuzzy finite element model in establishing sharp bounds to the uncertain structural response in the presence of multiple uncertainties.

Measurement of workload by cardiac arrhythmia (부정맥을 이용한 작업부하의 평가)

  • 박영택;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 1983
  • While three subjects were running on treadmill at five different speeds, their heart beat interval times were measured and analyzed. From the analysis, we discovered some relation- ships between workload and cardiac response, especially cardiac arrhythmia. Using these relationships, a physioligical model for estimating workload was developed. Although pulse rate has been considered as a good measure of physical load, this study shows that it is highly subject dependent and therefore unsuitable for task evalution. It is recommended to use range of heart beat interval times rather than pulse rate in the evaluation of light work.

  • PDF

Voltage Amplitude Control of Square-Wave VSIs with an R-L Load (R-L부하를 가진 구형파 VSI의 전압크기 제어)

  • Kim Kyung-Won;Hong Soon-Chan;Yoo Jong-Gul;Kim Sang-Kyun;Park Chae-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF

Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment (치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가)

  • Hwang, Jun Ho;Kwon, Sung-Min;Choi, Sung Gi;Sung, Mi Ae;Lee, Kyu-Bok
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.

Evaluation of full-order method for extreme wind effect estimation considering directionality

  • Luo, Ying;Huang, Guoqing;Han, Yan;Cai, C.S.
    • Wind and Structures
    • /
    • v.32 no.3
    • /
    • pp.193-204
    • /
    • 2021
  • The estimation of the extreme wind load (effect) under a mean recurrence interval (MRI) is an important task in the wind-resistant design for the structure. It can be predicted by either first-order method or full-order method, depending on the accuracy and complexity requirement. Although the first-order method with the consideration of wind directionality has been proposed, less work has been done on the full-order method, especially with the wind directionality. In this study, the full-order method considering the wind directionality is proposed based on multivariate joint probability distribution. Meanwhile, considering two wind directions, the difference of the corresponding results based on the first-order method and full-order method is analyzed. Finally, based on the measured wind speed data, the discrepancy between these two methods is investigated. Results show that the difference between two approaches is not obvious under larger MRIs while the underestimation caused by the first-order method can be larger than 15% under smaller MRIs. Overall, the first-order method is sufficient to estimate the extreme wind load (effect).

Behaviour Characteristics of Tunnel in the Cavity Ground by using Scale Model Tests (축소모형실험을 이용한 공동지반에서의 터널 거동특성)

  • Chung, Jeeseung;Moon, Innki;Yoo, Chanho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.61-69
    • /
    • 2013
  • As construction for road and train tunnel is increasing, various geotechnical conditions can be faced during the construction stage. Especially, if the tunnel is located in limestone area, the cavity is mostly to locate in tunnel planning location. One or some cavities which can be harmful for tunnel safety are predicted. Hence, this study was fulfilled to confirm the influence between tunnel and cavity using laboratory scale down model test and numerical analysis. The scale down model test was carried out to confirm the failure load of the model ground about the interval length of cavity and tunnel and to analyze behaviour characteristics of the model ground on the cavity shape. From the model test result, the failure load decrease in accordance with decreasing of interval length between cavity and tunnel within 0.5D. The numerical analyses were carried out for verification about scale down model test. From the numerical analysis result, tunnel safety decreases in the case of the interval between cavity and tunnel within 0.5D.

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement (유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구)

  • Um, Chan Hee;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1015-1024
    • /
    • 2015
  • An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

Batch Time Interval and Initial State Estimation using GMM-TS for Target Motion Analysis (GMM-TS를 이용한 표적기동분석용 배치구간 및 초기상태 추정 기법)

  • Kim, Woo-Chan;Song, Taek-Lyul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.285-294
    • /
    • 2012
  • Using bearing measurement only, target motion state is not directly obtained so that TMA (Target Motion Analysis) is needed for this situation. TMA is a nonlinear estimation technique used in passive SONAR systems. Also it is the one of important techniques for underwater combat management systems. TMA can be divided to two parts: batch estimation and sequential estimation. It is preferable to use sequential estimation for reducing computational load as well as adaptively to target maneuvers, batch estimation is still required to attain target initial state vector for convergence of sequential estimation. Selection of batch time interval which depends on observability is critical in TMA performance. Batch estimation in general utilizes predetermined batch time interval. In this paper, we propose a new method called the BTIS (Batch Time Interval and Initial State Estimation). The proposed BTIS estimates target initial status and determines the batch time interval sequentially by using a bank of GMM-TS (Gaussian Mixture Measurement-Track Splitting) filters. The performance of the proposal method is verified by a Monte Carlo simulation study.

Model Tests for Vertical Loads Acting on Embankment Piles (성토지지말뚝에 작용하는 연직하중에 대한 모형실험)

  • 홍원표;강승인
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.171-181
    • /
    • 2000
  • A series of model tests were performed both to investigate the load transfer by soil acrching in fills above embankment pils and to verify of the theoretical analysis. In the model tests, the piles were installed in a row below the embankment and the cap beams were placed on the pile heads perpendicular to the longitudinal axias of the embankment. The space between pile cap beams and the embankment height was focused as the major factors affecting the load transfer in embankment fill. When the embankment fill was higher than the minimum required height, which was about 33% higher than the radius of the soil arch proposed by theoretical discussion in the previous study, not only the soil arching could be developed completely but also the experimental results showed good agreement with theoretical predictions. The portion of the embankment load carried by model pile cap beams decreased with increment of the space between pile cap beams, while it increased with increment of the embankment height. Therefore, to maximize the effect of embankment load transfer by piles on design, the interval ratio of pile cap beams should be decreased under considerably high embankments by reducing the space between cap beams and/or enlarging the width of pile cap beams.

  • PDF

Pollutant Load Delivery Ratio for Flow Duration at the Chooryeong-cheon Watershed (추령천 유역의 유황별 유달율 계산)

  • Kim, Young-Joo;Yoon, Kwang-Sik;Son, Jae-Gwon;Choi, Jin-Kyu;Chang, Nam-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.19-26
    • /
    • 2010
  • To provide the basic information for the water quality management of the Sumjin River Basin, delivery ratios for flow duration were studied. Using the day-interval data set of discharge and water quality observed from the Chooryeong-cheon watershed, the flow-duration and discharge-load relation curves for the watershed were established, then the load-duration curve was constructed. Delivery ratios for flow duration were also developed. Delivery ratios showed wide variation according to flow conditions. In general, delivery ratio of high flow condition showed higher value reflecting nonpoint source pollution contribution from the forest dominating watershed. To resolve this problem, a regression model explaining the relation between flow rate and delivery ratio was suggested. The delivery ratios for different flow regime could be used for pollutant load estimation and TMDL (Total maximum daily load) development.