• 제목/요약/키워드: interstory drift angle

검색결과 5건 처리시간 0.019초

Seismic and progressive collapse assessment of SidePlate moment connection system

  • Faridmehr, Iman;Osman, Mohd Hanim;Tahir, Mahmood Bin Md.;Nejad, Ali Farokhi;Hodjati, Reza
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.35-54
    • /
    • 2015
  • The performance of a newly generated steel connection known as SidePlateTM moment connection for seismic loading and progressive collapse phenomenon has been investigated in this paper. The seismic evaluation portion of the study included a thorough study on of interstory drift angles and flexural strengths based on 2010 AISC Seismic Provisions while the acceptance criteria provided in UFC 4-023-03 guideline to resist progressive collapse must be satisfied by the rotational capacity of the connections. The results showed that the SidePlate moment connection was capable of attaining adequate rotational capacity and developing full inelastic capacity of the connecting beam. Moreover, the proposed connection demonstrated an exceptional performance for keeping away the plastic hinges from the connection and exceeding interstory drift angle of 0.06 rad with no fracture developments in beam flange groove-welded joints. The test results indicated that this type of connection had strength, stiffness and ductility to be categorized as a rigid, full-strength and ductile connection.

강구조 성능기반설계를 위한 접합부의 내진성능평가치 제안 (The Suggestion of Seismic Performance Values on Connections for Performance Based Design of Steel Structures)

  • 오상훈;오영석;홍순조;이진우
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.147-158
    • /
    • 2011
  • 본 연구의 목적은 국내 강구조 성능기반설계를 위한 접합부의 내진성능평가치를 제안하는 것에 있다. 최근 성능설계에 대한 기초연구가 국내, 외에서 증가하고 있으며, 본 연구에서는 외국의 성능설계기법을 조사, 분석하여 강구조 건축물의 성능한계분류를 제안하였다. 제안된 성능한계분류에 따라 강구조에 적합한 공학량으로서 내진성능규정치를 제시할 필요가 있다. 그 첫 번째 단계로 강구조 실대형 실험을 통한 접합부의 실험결과를 중심으로 기초자료를 조사하여 작성하였다. 모멘트 골조 접합부의 실험 데이터에서 얻은 모멘트-회전각 관계를 이용하여 항복하중 이하에 존재할 것으로 판단되는 기능한계와 손상한계는 층간변형각으로 구분하였다. 또한 항복하중과 최대하중 사이에 존재할 것으로 판단되는 복구한계와 안전한계는 소성율과 누적소성변형배율을 조사하여 구분하였다.

콘크리트채움 U형 강재보 - 콘크리트 기둥 접합부의 내진성능 (Seismic Resistance of Concrete-filled U-shaped Steel Beam-to-RC Column Connections)

  • 황현종;박홍근;이철호;박창희;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.83-97
    • /
    • 2011
  • 본 논문에서는 콘크리트 채움 U형 강재보와 철근콘크리트 기둥으로 구성된 접합부의 내진 상세를 개발하였다. 접합부 내진성능을 평가하기 위하여 세 개의 보-기둥 접합부 실험체를 반복주기하중에 대하여 실험하였다. 보춤과 기둥 단면 형상을 실험 변수로 하였다. 합성보의 춤은 슬래브 두께를 포함하여 610mm, 710mm이며, 철근콘크리트 기둥은 사각단면과 원형단면이 사용되었다. 접합부를 보강시키기 위하여 사각단면 기둥과 원형단면 기둥에 각각 대각 철근과 외다이어프램 강판을 사용한 특수 상세가 사용되었다. 실험 결과 실험체는 강도와 변형능력, 에너지 소산에 있어서 우수한 성능을 보여주었다. 변형능력은 특수모멘트골조 기준인 4% 이상의 층간변위각을 발휘하였다.

Seismic behavior of steel truss reinforced concrete L-shaped columns under combined loading

  • Ning, Fan;Chen, Zongping;Zhou, Ji;Xu, Dingyi
    • Steel and Composite Structures
    • /
    • 제43권2호
    • /
    • pp.139-152
    • /
    • 2022
  • Steel-reinforced concrete (SRC) L-shaped column is the vertical load-bearing member with high spatial adaptability. The seismic behavior of SRC L-shaped column is complex because of their irregular cross sections. In this study, the hysteretic performance of six steel truss reinforced concrete L-shaped columns specimens under the combined loading of compression, bending, shear, and torsion was tested. There were two parameters, i.e., the moment ratio of torsion to bending (γ) and the aspect ratio (column length-to-depth ratio (φ)). The failure process, torsion-displacement hysteresis curves, and bending-displacement hysteresis curves of specimens were obtained, and the failure patterns, hysteresis curves, rigidity degradation, ductility, and energy dissipation were analyzed. The experimental research indicates that the failure mode of the specimen changes from bending failure to bending-shear failure and finally bending-torsion failure with the increase of γ. The torsion-displacement hysteresis curves were pinched in the middle, formed a slip platform, and the phenomenon of "load drop" occurred after the peak load. The bending-displacement hysteresis curves were plump, which shows that the bending capacity of the specimen is better than torsion capacity. The results show that the steel truss reinforced concrete L-shaped columns have good collapse resistance, and the ultimate interstory drift ratio more than that of the Chinese Code of Seismic Design of Building (GB50011-2014), which is sufficient. The average value of displacement ductility coefficient is larger than rotation angle ductility coefficient, indicating that the specimen has a better bending deformation resistance. The specimen that has a more regular section with a small φ has better potential to bear bending moment and torsion evenly and consume more energy under a combined action.

다목적 최적화 기법을 이용한 편심가새골조의 역량설계 (Capacity Design of Eccentrically Braced Frame Using Multiobjective Optimization Technique)

  • 홍윤수;유은종
    • 한국전산구조공학회논문집
    • /
    • 제33권6호
    • /
    • pp.419-426
    • /
    • 2020
  • 본 연구에서는 철골편심가새골조 시스템을 대상으로 다목적최적화기법을 통해 설계를 수행하고 그 결과를 분석하였다. 최적화 설계를 위해 유전 알고리즘의 일종인 NSGA-II를 활용하였다. 여기서, 목적함수는 이율배반적 관계를 갖는 구조물량과 층간변위로 하여 최소화되고, 제약조건에는 구조기준에서 요구하는 내력비, 링크의 회전각 등을 포함하였다. 제약조건은 최적화 알고리즘 내에서 각 항목을 위반할수록 목적함수 값을 크게 증가시키는 벌금함수의 형태를 가지고 있다. 설계기준에서 EBF 시스템의 설계규정은 링크 부재만 항복이 허용되며 나머지 부재는 링크 항복 시 발생되는 부재력을 탄성상태에서 견디도록 의도한 역량설계법에 기초한다. 그러나 최적화를 통해 도출된 결과 중 일부는 구조기준의 설계조항은 만족하지만 특정층 링크에 소성변형이 집중되어 연약층을 형성함으로써 기준에서 의도하는 역량설계의 원칙을 위배하는 결과가 나타났다. 이를 해결하기 위해 모든 링크의 전단 초과강도계수 중 최대값이 최소값의 1.25배를 넘지 않도록 하는 제약식을 추가하였다. 새로운 제약식을 추가한 경우 모든 최적해는 설계기준과 역량설계의 원칙을 준수하는 것으로 나타났다. 모든 설계안에서 보 경간에 대한 링크의 길이비는 전단링크의 범주에 해당하는 10% ~ 14%였다. 전체적으로 설계안들은 링크의 초과강도 계수비가 가장 지배적인 제약으로 작용하였으며, 구조기준의 요구사항 중 층간변위와 내력비 등의 항목에서 허용치에 비해 매우 보수적으로 설계되었다.