• Title/Summary/Keyword: interruption

Search Result 1,055, Processing Time 0.028 seconds

Morphological and Photoluminescence Characteristics of Laterally Self-aligned InGaAs/GaAs Quantum-dot Structures (수평 자기정렬 InGaAs/GaAs 양자점의 형태 및 분광 특성 연구)

  • Kim J. O.;Choe J. W.;Lee S. J.;Noh S. K.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Laterally self-aligned InGaAs/GaAs quantum-dots (QDs) have been fabricated by using a multilayer stacking technique. For the growth optimization, we vary the number of stacks and the growth temperature in the ranges of 1-15 periods and $500-540^{\circ}C$. respectively, Atomic force microscope (AFM) images and photoluminescence (PL) spectra reveal that the lateral alignment of QDs is enhanced in extended length by an increased stack period, but severely degrades into film-like wires above a critical growth temperature. The morphological and the photoluminescence characteristics of laterally self-aligned InGaAs QDs have been analyzed through mutual comparisons among four samples with different parameters. An anisotropic arrangement develops with increasing number of stacks, and high-temperature capping allows isolated QDs to be spontaneously organized into a one-dimensionally aligned chain-like shape over a few ${\mu}m$, Moreover, the migration time allowed by growth interruption plays an additional important role in the chain arrangement of QDs. The QD chains capped at high temperature exhibit blue shifts in the emission energy, which may be attributed to a slight outdiffusion of In from the InGaAs QDs.

Effect of Cathode Porosity of Mixed Conducting (La0.6Sr0.4Co0.2Fe0.8O3) on the Power Generating Characteristics of Anode Supported SOFCs (혼합전도체 LSCF(La0.6Sr0.4Co0.2Fe0.8O3) 양극의 기공률에 따른 음극지지형 단전지의 출력특성 평가)

  • Yun, Joong-Cheul;Kim, Woo-Sik;Kim, Hyoungchul;Lee, Jong-Ho;Kim, Joosun;Lee, Hae-Weon;Kim, Byong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.4
    • /
    • pp.269-275
    • /
    • 2005
  • We analyzed the unit cell performance against the cathode porosity, which is supposed to be closely related with active sites for the cathode reaction. In order to fabricate the unit cells with different porosity in the cathode layer we changed the mixing ratio of fine and coarse LSCF cathode powders. The final porosity of each cathode layer was 14, 23, 27, $39\%$ respectively. According to the electrochemical analysis of unit cell performance via DC current interruption and AC impedance method, the electrodic polarization resistance was diminished as the cathode porosity increased. The decrease of polarization resistance was attributed due to the increase of active reaction sites and the enhancement of overall unit cell performance could be explained in the same line.

Experimental Analysis in the Reversible and Irreversible Cerebral Ischemic Models in the Rat (백서의 가역성 및 비가역성 뇌허혈 모형의 실험적 고찰)

  • Song, Kwang Chul;Choi, Byung Yon;Kim, Seong Ho;Bae, Jang Ho;Kim, Oh Lyong;Cho, Soo Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.853-860
    • /
    • 2000
  • Objective : The purpose of our experimental study was to analysis the advantages and disadvantages in the reversible and irreversible cerebral ischemic models with rats by staining with Neutral Red(NR) solusion, 2% 2,3,5-triphenyltetrazolium chloride(TTC) and Hematoxylin & Eosin(H & E). Methods : We have measured the range of cerebral infarction in the rat to get a suitable ischemic model along the object of study with and without craniectomy. With craniectomy, 9 rats were sacrificed for irreversible cerebral ischemic model by means of ligation at proximal(group I) and distal(group II), and coagulation at proximal(group III) middle cerebral artery. Also, 6 rats were sacrificed for irreversible(group IV) and reversible(group V) cerebral ischemic model using nylon thread without craniectomy. The sizes of infarction were measured by staining the coronal sections of the brain with NR solusion, TTC and H & E. Results : There are no difference of physiological parameters comparing the each group. Cerebral infarction was not observed in group II, but it's volume was largest in group IV. Disadvantages of craniectomy group(I, II, III) are the long duration of operation and cortical damage by procedure. It's advantage is confirmation of the middle cerebral artery occlusion and cessation of blood flow through the operative microscope. In case of ischemic models using nylon thread (group IV, V), it is hard to identify the interruption or recirculation of blood flow through the middle cerebral artery, but the advantage is the simplicity of operative technique which reduces the operation time and minimizes the cerebral damage due to craniectomy. Therefore, it seems important to set up the reversible and irreversible ischemic models by carefully considering advantages and disadvantages listed above. Conclusion : TTC staining seems to be effective since it reflects the histological damage sufficiently and quickly. It is hoped that researches focused on ischemic penumbra, which became popular recently, will be further carried on with use of NR staining, optical microscope and electron microscope.

  • PDF

The analysis of trends in domestic research on career development of nurses (간호사 경력개발에 관한 국내 연구 동향 분석)

  • Choi, Hyun-Ju;Jung, Kwuy-Im
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.325-336
    • /
    • 2018
  • This study was conducted to explore the latest trends in domestic research related to career development for nurses and present a theoretical approach and practical direction of career related papers in the field of nursing and health care. The subject of the study was articles regarding career development of nurses published in domestic journals from 2008 to 2017. The final 29 papers were found after searching the RISS and KISS databases for 'nursing', 'nurse', 'career', 'career development', 'career development program', and 'career management.' To analyze the overall trends, the analysis was reviewed by year, source, research design, and subjects, and content analysis was used to identify trends by topic. The results of content analysis were divided into career development and career development results as the upper categories. The subcategories of career development were divided into organizational career management, personal career management, and career performance. The subcategories of personal career management consisted of career exploration, career planning, career plateau, and career interruption. Organizational career management consisted of CLS development and application, CLS awareness survey, and career development model building. Career performance consisted of career commitment, organizational commitment, turnover intention, change after CLS application, career satisfaction, and career withdrawal intention. The most frequently discussed topics were career commitment among career performance. Therefore, the direction of nursing research related to career development requires integrated research that meets personal and organizational needs, and diversity in subject, research design and research theme is required.

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

Methods of The Promoting Blood Circulation and Removing Blood Stasis by Wang Cheong-Im (왕청임(王淸任)의 활혈거어법(活血祛瘀法))

  • Kim Hya-Sung;Jung Seung-Woo;Lee Jong-Il;Kwon Dong-Yeul
    • Herbal Formula Science
    • /
    • v.12 no.2
    • /
    • pp.47-55
    • /
    • 2004
  • Wang Cheong-Im(1768-1831) in the Ching dynasty conducted the therapy of blood statis syndrome using the methods for promoting blood circulation and removing blood statis in accordance with the description in the book Uirimgaechak(醫林改錯). Thus, this study examined his methods for promoting blood circulation and removing blood statis, therapy of blood statis syndrome and mechanism of function. Since the blood statis symptoms varied on the parts where the blood statis were occurred, the therapy for promoting blood circulation and removing blood statis applied different treatments and drugs depending on the symptoms. The therapy also valued much of qi and blood. Qi is important to the human body so that the therapy replenished qi and simultaneously promoted the blood circulation as mainly focusing on the regulation of the qi flow. Moreover, the therapy adjusted the level of removing blood circulation and rate of replenishing qi. The degree of prescription and drug was differentiated in treating a variety of blood statis because of the difference in the seriousness and characteristics of blood circulation, amount and application of drug and combination of drugs. The therapy was careful about the regulation of qi for the replenishment of qi and the nurishment of blood for the promotion of blood circulation. If the blood circulation was blocked, the blood statis was formed. Accordingly, the phlegm and the blood statis were closely related. Then, the phlegm and blood statis were simultaneously treated. The therapy divided the properties of blood statis into the stagnant excess syndrome, the stagnant deficiency syndrome, the stagnant cold syndrome and the stagnant heat syndrome and treated the patients suitable for each symptom. The function of mechanism in the treatment using the methods for promoting blood circulation and removing blood statis was divided into the stagnation of blood and interruption in blood circulation. The therapy laid stress on promoting blood circulation and removing blood circulation. With such emphasis, the therapy facilitated the circulation in the bloood vessel, prevented the coagulation of blood, removed the blood statis and promoted the metabolism. Then, the physiological function and pathological change internal organs were improved. Furthermore, the therapy strengtened the heart and promoted the blood circulation by improving the systemic blood circulation. Moreover, the therapy facilitated the micro-circulation by adjusting the balance of body.

  • PDF

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.

A retrospective clinical study of isolated patent ductus arteriosus (동맥관 개존증의 임상적 고찰)

  • 곽영태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.593-606
    • /
    • 1984
  • With the ligation of patent ductus arteriosus by Gross in 1938, surgeons first entered the field of congenital heart disease. Interruption of a ductus is one of the most satisfactory and curative operations in the field of surgery for congenital heart disease. 27 cases of isolated patent ductus arteriosus were operated from Jan. 1978 to July 1984 at the Department of Thoracic & Cardiovascular Surgery in Kyung-Hee University Hospital. Retrospective clinical analysis of these patients were: 1. Sex ratio, female: male, was 2:1. 2. Mean age at operation was 9.85\ulcorner.58 years. The youngest patient was a 23 month-old girl and the oldest one was a 24 year-old male. 3. More than half of the patients had less than 50 percentile of growth retardation. 4. Chief complaints of the patients were frequent URI [52%], dyspnea on exertion [33%], generalized weakness [22%], palpitation [7%], but 7 patients [26%] had no subjective symptoms. 5. Continuous machinery murmur could be heard at the 2nd or 3rd intercostal space on the left sternal border in 22 patients [81%]. The other S patients made systolic murmur with accentuation of the second heart sound and those were associated with pulmonary hypertension. 6. Radiologic findings of Chest P-A were cardiac enlargement in 15 patients [55%], enlargement of pulmonary conus and/or increasing density of pulmonary vascularity in 20 patients [74%]. 7. Electrocardiographic findings of the patients were within normal limit in 13 patients [48%], LVH in 4 patients [15%], biventricular hypertrophy in 3 patients [11%]. 8; echocardiogram was obtained from 11 patients. Ductus was directly visualized in 7 patients. Left atrial enlargement is the secondary change of left to right shunt, 10 patients had LA/Ao ratio more than 1.2. 9. Cardiac catheterization performed in 25 patients. The mean value of the results were:SO2[PA-RV]= 14.72\ulcorner6.01%, Qp/Qs=2.22\ulcorner.80, peak systolic pulmonary arterial pressure=48.28\ulcorner1.60 mmHg. 10. 26 patients were operated through the left posterolateral thoracotomy: closure of ductus by double ligation in 14 cases, triple ligation in 5 cases, and division with suture in 8 cases. One patient suffer from aneurysmal rupture of main pulmonary artery, endocarditis, hemopericardium was treated with cardiopulmonary bypass via median sternotomy and closure of ductus through the ruptured main pulmonary artery. 11.There was no death associated with the operation, but 3 cases were experienced with intraoperative rupture around the ductus resulting in massive bleeding. The other complications were transient hoarseness in one patient, atelectasis in left lower lobe in 3 patients, and postoperative systemic hypertension in 4 patients with unknown etiology. 12. Pulse pressure was reduced, 11.47+5.92 mmHg, postoperatively, as compare to preoperative status. 13. Intraoperative wedge lung biopsy from lingular segment for the evaluation of the pulmonary vascular disease was taken in S patients with severe pulmonary hypertension. The result was Heath-Edward grade I in one case, grade II in two cases, and grade III in two cases.

  • PDF

Flowering Control by Using Red Light of Chrysanthemum (적색광을 이용한 국화의 개화조절)

  • Hong, Seung-Chang;Kwon, Soon-Ik;Kim, Min-Kyeong;Chae, Mi-Jin;Jung, Goo-Bok;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.2
    • /
    • pp.123-127
    • /
    • 2013
  • BACKGROUND: The incandescent bulb and compact fluorescent lamp are widely using as a light sources for daylength extension of chrysanthemum. But, these light sources consume a lot of electricity and have short longevity. A light-emitting diode (LED) is a semi conductor light source. LEDs have many advantages over incandescent light sources including lower energy consumption, longer lifetime. In this study, we investigated the intensity of red light to control flowering of chrysanthemum (Dendranthema grandiflorum cv. "Shinma") by using LEDs. METHODS AND RESULTS: The red (660 nm) and far-red (730 nm) light were irradiated subsequently to investigate photo-reversible flowering responses of chrysanthemum. The flowering of chrysanthemum was inhibited by night interruption with red light but subsequently irradiated far-red light induced the flowering of chrysanthemum. This photoreversibility, reversion of the inductive effect of a brief red light pulse by a subsequent far-red light pulse, is a property of photo responses regulated by the plant photoreceptor phytochrome B. Four different intensity of red light of 0.7, 1.4, 2.1, and $2.8{\mu}mol/m^2/s$ (PAR) were irradiated at growth room in order to determine the threshold for floral inhibition of chrysanthemum. Over $1.4{\mu}mol/m^2/s$ of the red lights irradiated chrysanthemums were not flowered. The plant length, fresh weight, number of leaves, and leaf area of chrysanthemum irradiated with red light were increased by 17%, 36%, 11%, and 48%, respectively, compared to those of compact fluorescent lamp. CONCLUSION(S): The red light and subsequential far-red light showed that the photoreversibility on flowering of chrysanthemum. The red light ($1.4{\mu}mol/m^2/s$ of red LEDs) and white light (50 Lux of compact fluorescent lamp) have the same effect on inhibition of flowering in chrysanthemum. Additionally, the red light increased the plant height and dry weight of chrysanthemum.

Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages (서지전압에 대한 50[A]용 누전차단기의 부동작 특성)

  • 이승칠;장석훈;이복희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.44-52
    • /
    • 1997
  • Electronic circuits with semiconductor and IC are very weak against the surge voltage and currents. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of the earth leakage circuit breaker(ELB) due to the operation of surge protective devices, and the interruption of AC power lines on account of the malfunction of the ELB brings about several disadvantages such as low operation efficiency and reliability of electronic and informational systems, economical loss, and etc. The aim of the present work is to investigate the dead operation characteristics of the ELB against the surge voltages. The impulse generator of 10[kV) in an 1.2/ 50[~) voltage waveform was fabricated. The dead operation characteristics of the ELB applied by surge voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a consequence, the peak value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not bring about dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELB installed at the AC power lines with the surge protective devices bring about the dead operation.

  • PDF