• Title/Summary/Keyword: interobserver reliability

Search Result 38, Processing Time 0.018 seconds

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.

A COMPARISON OF SCANORA$\textregistered$ RADIOGRAPHY WITH WATERS' AND PANORAMIC VIEWS FOR THE DETECTION OF MUCOSAL THICKENING OF MAXILLARY SINUS (워터스, 파노라마 방사선사진과 Scanora$\textregistered$ 방사선사진의 상악동 점막비후 진단 결과의 비교)

  • Yoon Suk-Ja;Jung Hyun-Dae;Kang Byung-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.389-398
    • /
    • 1995
  • The purpose of this study was to compare the diagnostic performance of Waters' and panoramic view; maxillary sinus posteroanterior and lateral scanography of Scanora/sup (R)/ for mucosal thickening of maxillary sinus as well as to identify the utility of Scanora/sup (R)/ for the detection of maxillary sinus disease. The assessment was done at 66 maxillary sinuses in 45 patients and the results were as follows ; 1. Estimation of presence or absence of mucosal thickening. The sensitivity, specificity, and positive and negative predictive value of maxillary sinus posteroanterior and lateral scanography were 0.865, 0.860, 0.921, and 0.805 respectively and slightly higher than those of Waters' and panoramic views, which were 0.832, 0.835, 0.903, and 0.728 respectively. However, paired t-test showed no significant differences in the diagnostic performance of the two pairs of imaging modalities. 2. Estimation of the types of mucosal thickening. The diagnostic accuracy for type I, II, III was 75.3% on Waters' and panoramic view; 77.9% on maxillary sinus posteroanterior and lateral scanography. It was higher on the latter ,but showed no significant differences from that on the former. 3. Reliability of interpretation. In itraobserver and interobserver agreement, both overall rates of agreement and kappa-value were slightly higher on maxillary sinus posteroanterior and lateral scanography than on Waters' and panoramic views. There was no significant differences between the two pairs of imaging modalities. These results suggested that scanogram is a useful diagnostic radiography as well as Waters' and panoramic views for detection of maxillary sinusitis.

  • PDF

Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography

  • Rosado, Lucas de Paula Lopes;Barbosa, Izabele Sales;de Aquino, Sibele Nascimento;Junqueira, Rafael Binato;Verner, Francielle Silvestre
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • Purpose: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs(PR) and cone-beam computed tomography (CBCT). Materials and Methods: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. Results: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial(0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better(P<0.05). Conclusion: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

Reliable Radiologic Parameters to Predict Surgical Management for Clubfoot Treated with the Ponseti Method (Ponseti 방법으로 치료를 시작한 선천성 만곡족 환자에서 수술적 치료 여부를 예측할 수 있는 방사선적 지표)

  • Song, Kwang Soon;Yon, Chang Jin;Lee, Si Wook;Lee, Yong Ho;Um, Sang Hyun;Kwon, Hyuk Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • Purpose: Several radiologic reference lines have been used to evaluate individuals with a clubfoot but there is no consensus as to which is most reliable. The aim of this study was to identify which radiologic parameters have relevance to the predictability of additional surgery after Ponseti casting on clubfoot and the effect of clubfoot treatments that contain Ponseti casting and additional surgery. Materials and Methods: A total of 102 clubfeet (65 patients, 37 bilateral) were reviewed from 2005 to 2013. The patients were divided into two groups (Group A, those for whom the result of the Ponseti method was successful and did not require additional surgery; and Group B, those for whom the result of the Ponseti method was unsuccessful and required additional surgery), and the following parameters were measured on the plain radiographs: i) talo-calcaneal angle on the anteroposterior and lateral view, ii) talo-1st metatarsal angle on the anteroposterior view, and iii) Tibio-calcaneal angle on the lateral view with the ankle full-dorsiflexion state. Each radiograph was reviewed on two separate occasions by one orthopedic doctor to characterize the intra-observer reliability, and the averages were analyzed. Next, 20 cases were chosen using a random number table, and two orthopedic doctors measured the angle separately to characterize the interobserver reliability. Results: Groups A and B included 73 clubfeet (71.6%) and 29 clubfeet (28.4%), respectively. The initial talo-calcaneal angle and tibiocalcaneal angle in the lateral view were significantly different among the groups. In addition, inter- and intra-observer biases were not detected. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view were significantly different after treatment in both groups. Conclusion: Congenital clubfeet treated with the Ponseti method showed successful results in more than 70% of patients. The initial talocalcaneal angle and tibio-calcaneal angle on the lateral view were the radiologic parameters that could predict the need for additional surgical treatments. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view could effectively evaluate the changes in clubfoot after treatment.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF