• 제목/요약/키워드: internal wave

검색결과 625건 처리시간 0.022초

초음파 비파괴 검사를 이용한 AISI 304 스테인리스강의 크리프-피로 손상의 평가 (Evaluation of Creep-Fatigue Damage in 304 Stainless Steel using Ultrasonic Non-Destructive Test)

  • 이성식;오용준;남수우
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.924-929
    • /
    • 2011
  • It is well known that grain boundary cavitation is the main failure mechanism in austenitic stainless steel under tensile hold creep-fatigue interaction conditions. The cavities are nucleated at the grain boundary during cyclic loading and grow to become grain boundary cracks. The attenuation of ultrasound depends on scattering and absorption in polycrystalline materials. Scattering occurs when a propagation wave encounters microstructural discontinuities, such as internal voids or cavities. Since the density of the creep-fatigue cavities increases with the fatigue cycles, the attenuation of ultrasound will also be increased with the fatigue cycles and this attenuation can be detected nondestructively. In this study, it is found that individual grain boundary cavities are formed and grow up to about 100 cycles and then, these cavities coalesce to become cracks. The measured ultrasonic attenuation increased with the cycles up to cycle 100, where it reached a maximum value and then decreased with further cycles. These experimental measurements strongly indicate that the open pores of cavities contribute to the attenuation of ultrasonic waves. However, when the cavities develop, at the grain boundary cracks whose crack surfaces are in contact with each other, there is no longer any open space and the ultrasonic wave may propagate across the cracks. Therefore, the attenuation of ultrasonic waves will be decreased. This phenomenon of maximum attenuation is very important to judge the stage of grain boundary crack development, which is the indication of the dangerous stage of the structures.

판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발 (Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor)

  • 김회웅;김상활;한재원;주영상;박창규;김종범
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.48-57
    • /
    • 2015
  • 제 4세대 원자로로 개발되고 있는 소듐냉각고속로는 냉각재로 사용되는 소듐의 물과 공기에 의한 반응을 방지하기 위하여 원자로 헤드의 개방 없이 회전 구동만을 이용하여 핵연료 교환을 수행한다. 따라서 핵연료 교환을 위해서는 노심과 상부내부구조물 사이의 공간에 원자로 헤드의 회전 구동을 방해하는 장애물의 존재 여부를 확인하는 검사가 반드시 선행되어야 하는데, 소듐의 불투명성으로 인해 통상적인 광학 장비를 사용한 검사방법으로는 장애물의 확인이 어렵고, 초음파를 이용한 검사방법이 적용되어야 한다. 이 연구에서는 불투명한 소듐 중에서 노심과 상부내부구조물 사이의 장애물 존재 여부를 확인하기 위하여 판형 웨이브가이드 초음파 센서를 적용한 원격주사 검사기법을 개발하였다. 웨이브가이드 센서는 원자로헤드 상부의 저온 구간에 초음파 트랜스듀서를 설치하고 길이가 긴 웨이브가이드를 사용하여 노심 상부의 고온 고방사능 소듐 내부로 초음파를 전파시키기 때문에, 고온 고방사능에 의한 손상 없이 장시간 적용이 가능한 장점을 가지고 있다. 먼저, 수평 방향으로 초음파를 방사시킬 수 있는 10 m 길이의 수평 빔 웨이브가이드 센서를 설계 제작하였고, 제작된 센서의 특성 분석을 위한 빔 프로파일 측정 및 기초 실험을 수행하여 방사되는 초음파의 빔 폭과 전파 거리를 평가하였다. 또한, 실제 장애물로 작용할 수 있는 부품들의 형상인 원형 목표물에 대한 원격탐지 성능시험을 수행하여 개발된 원격주사 기술의 유용성을 평가하였다.

FPSO 안정성 평가를 위한 절단계류선 모델링 수치 연구 (Numerical Study on Designing Truncated Mooring Lines for FPSO Stability Analysis)

  • 김윤호;조석규;성홍근;서장훈;서용석
    • 한국해양공학회지
    • /
    • 제28권5호
    • /
    • pp.387-395
    • /
    • 2014
  • In this paper, a numerical analysis for an internal turret moored vessel located at a 400-m water depth is conducted. The target vessel has an internal turret that is located at the 0.2 Lpp position from the fore-side, with $3{\times}4$ complex mooring lines installed around the turret circumference. To investigate the motion response of the vessel and the structural reliability of the lines, model tests were conducted. The KRISO ocean basin has a water depth of 3.2 m, which represents 192m using a scaling of 1:60. In order to precisely represent the real-scale condition, equivalent mooring lines needed to be designed. Truncated mooring lines were designed to supplement the restriction of the flume's water depth and increase the reliability of the model testing. These truncated mooring lines were composed of two different chains in order to match the pre-tension, simultaneously restoring the curve and variation in the effective line tension. The static similarities were compared using a static pull-out test and free decaying test, and the dynamic similarities were matched via a regular wave test and combined environments test. Consequently, the designed truncated mooring system could represent the prototype mooring system relatively well in the aspects of kinematics and dynamics.

내부 유체 슬로싱 효과를 고려한 부유이송 해상풍력 기초의 동적 안정성 해석 (Dynamic Stability Analysis of Floating Transport Wind-Turbine Foundation Considering Internal Fluid Sloshing Effect)

  • 홍석진;김동현;강신욱;강금석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.461-467
    • /
    • 2016
  • 부유 이송식 해상풍력 기초를 목표 지점에 설치하기 위해서는 내부의 중공부에 해수를 주입하여 착저 시키게 되는데, 그 과정에서 중량 및 무게 중심과 부력중심이 변하게 되어 부유식 기초가 불안정해 질 수 있다. 부유 이송식 기초의 동적안정성 해석은 기초 외부의 수력학적 하중과 6-자유도 운동을 하게 되는 기초에 작용하는 파도와 조류 하중 및 설치 과정에서 기초 내부의 중공부로 투입되는 해수의 무게중심 이동까지 동시에 고려해야 하는 복잡한 문제이다. 따라서 본 연구에서는 3차원 비정상 CFD 기법과 다물체 동역학 기법을 연성 (coupling)한 정밀 해석기법을 적용하여 부유 이송식 기초 내부 물의 슬로싱 운동까지 고려한 동적안정성 해석을 수행하고 특성을 분석하였다.

가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법 (UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear)

  • 송원표;김정배;김민수;정재룡;박승재;고희석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

유체 순환 혈압 시뮬레이터의 구현 (Implementation of The Fluid Circulation Blood Pressure Simulator)

  • 김철한;이규원;남기곤;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

천궁(川芎)의 형태(形態)에 관한 연구(硏究) (A Study on a Morphological Identification of Cnidium Rhizome and Ligusticum Rhizome)

  • 최정국;임덕빈;이영종
    • 대한본초학회지
    • /
    • 제20권4호
    • /
    • pp.95-101
    • /
    • 2005
  • Objectives : In order to distinguish Cnidii Rhizoma and Ligustici Chuanxiong Rhizoma (cultivated in Korea and China), their external and internal states were observed via microscopic examination. Methods : The slice of the tested material made by paraffin section technique was colored with Safranine Malachite Green contrast methods, and then observed and photographed by olymphus-BHT. Results : Cnidii Rhizoma, Ligustici Chuanxiong Rhizoma (from Korea), and Ligustici Chuanxiong Rhizoma (from China) all demonstrated similar patterns as following : 1. external form 1) showing irregular nodular form with $2{\sim}7cm$ diameter. 2) having several trochites in parallel, and nodulose root trace on surface. 3) in addition to yellow-white or yellow-gray intersections, yellow-brown oil sacs were distributed, with cambium resembling a form of annulus. 2. internal form 1) its root and rhizome is composed of 10 layers of cork, with narrow cortical layers. 2) its phloem is wide, and oval light yellow-brown oil sacs are distributed around. The closer to the cambium, the smaller it is. 3) cambium is a form of a wave-like ring or an irregular polygon. 4) xylem and vessel are rare, most of which are arranged in a 'V' format, and sometimes xylem fiber is found. 5) pith is composed of parenchymatous cell, and parenchyma is full of starch grains. Conclusions : In conclusion, C officinale, L. chuanxiong (from Korea), and L. chuanxiong (from China) have rhizomes in a similar form with no special difference. Therefore, it is concluded that C. officinale, L. chuanxiong (from Korea), and L. chuanxiong (from China) are categorized into the same species.

  • PDF

과학로켓 모델의 정적 안정성에 대한 초음속풍동 실험연구 (Experimental Study on the Static Stability of a Sounding Rocket Model in the Supersonic Wind Tunnel)

  • 이상현;조환기;성홍계;김진곤
    • 한국항공우주학회지
    • /
    • 제38권9호
    • /
    • pp.856-861
    • /
    • 2010
  • 본 연구에서는 하이브리드 과학로켓의 공력특성을 파악하고 정적 세로 안정성에 대한 판단을 하기 위해서 초음속 풍동실험을 하였다. 과학로켓의 10% 축소모델에 대해서 마하수 1.75~2.5, 받음각 $0^{\circ}{\sim}6^{\circ}$의 조건에서 실험을 수행하였으며, 4분력 내장형 밸런스를 사용하여 실험모델의 공력과 모멘트를 측정하였다. 측정된 자료를 바탕으로 로켓의 안정성을 판단하였으며, 로켓의 길이효과를 분석하기 위하여 길이가 다른 3개의 모델에 대하여 실험을 수행하였다. 또한, 쉴리렌 광학장치를 이용하여 초음속 비행 시 발생하는 충격파를 가시화하고 속도 및 받음각 변화에 따른 충격파의 변화를 관찰하였다.

실시간 탄성초음파를 이용한 만성 뇌졸중 후 편마비 환자의 상지 강직에 대한 사암침 효과 연구 (Study of the Effects of Sa-am Acupuncture on Upper Limb Spasticity in Patients with Chronic Post-stroke Hemiparesis using Real-time Sonoelastography)

  • 백경민;권동락;박기영
    • 대한한방내과학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2014
  • Objectives : To investigate the effects of Sa-am acupuncture on muscle architecture and elastic properties of the spastic elbow flexor and to evaluate the correlation between clinical findings and parameters of real-time sonoelastography (RTS) in patients with chronic post-stroke hemiparesis. Materials and Methods : Seven patients (five males, two females) with chronic post-stroke hemiparesis were included. Sa-am acupuncture of Ganseunggyeok (肝勝格: LU8 LR4 補, HT8 LR2 瀉) was applied to the unaffected side 3 times a week for 4 weeks. During each acupuncture treatment period, patients were requested to exercise their affected arm, and spasticity and functional recovery outcomes of the affected arm were evaluated before and after Sa-am acupuncture treatment. Clinical outcomes were assessed using motricity index (MI), modified Ashworth scale (MAS), Fugl-Meyer assessment scale (FMA) and modified Barthel index (MBI) for elbow flexor spasticity. RTS images indicate the relative hardness of the examined muscles ranged from red (hard) to purple (soft) for color-scale, and from black (hard) to white (soft) for hue scale. Color and hue histograms of the biceps brachii and brachialis were analyzed using Image J software, and median red, blue, and hue pixel intensity were obtained. Results : MI and FMA score significantly increased and MAS score significantly decreased (p<0.05). F-wave maximal amplitude of affected abductor pollicis brevis significantly decreased (p<0.05). Muscle thickness of affected brachialis significantly increased (p<0.05). Red and green pixel intensity of affected brachialis significantly decreased (p<0.05). Conclusions : Our study revealed that Sa-am acupuncture is effective as a useful and safe treatment for spasticity in chronic post-stroke hemiparesis.

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권1호
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF