• Title/Summary/Keyword: internal reduction

Search Result 1,558, Processing Time 0.025 seconds

The usefulness of intermolar traction wiring for restoration of maxillary & mandibular dental arch in facial bone fracture (안면골 골절에서 상하악 치열궁 복원을 위한 양측 대구치간 철사견인술의 유용성)

  • Jeong, Jae Ho;Shin, Seung Kyu;Lee, Jun Ho;Kim, Yong Ha
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: Palatal fracture and mandible fracture result in instability of dental arch. Because they divide the maxillary and mandibular alveolus sagittally and / or transversely and comminute the dentition, they permit rotation of dental alveolar segments and significantly increase the potential for fracture malalignment, complicating fracture treatment. Previous treatment of palatal fracture consisted of palatal splint application and rigid palatal vault stabilization. This procedure result in patient's oral discomfort and removal of palate and screw. Mandible fracture often results in malocclusion due to widening of posterior aspect of dental arch. So we introduce more simple method using intermolar traction wiring, which can protect the widening of dental arch and rotation of dental alveolar segment. Methods: Arch bar and intermolar traction wiring with wire 1 - 0, or 2 - 0 was applied. After exposure of fracture line, neutrooclusion was maintained with intermaxillary fixation. And then open reduction & internal fixation on maxillary fracture line, commonly maxillary buttress, alveolar ridge, pyriform aperture except palatal vault or mandibular fracture line. After 1 week, intermolar traction wiring was removed. We checked occlusion and postoperative radiologic finding. Results: From June of 2007 to October of 2007, 10 patient, who have maxillary fracture with palatal fracture and mandible fracture, underwent open reduction & internal fixation with intermolar traction wiring. All have satisfactory occlusion and there were no complication, like gingiva disease, mouth opening impairment and nonunion. Conclusion: The intermolar traction wiring accompany open reduction and internal fixation can be alternative method for restoration of dental arch in facial bone fracture.

Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction (막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석)

  • Kim, Kyeong-Rae;Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Comparative analysis of proximal humerus fracture management in elderly patients: complications of open reduction and internal fixation by shoulder surgeons and non-shoulder surgeons-a retrospective study

  • Rui Claro;Bianca Barros;Carlos Ferreira;Ana Ribau;Luis Henrique Barros
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • Background: Open reduction and internal fixation (ORIF) with a locking plate is a popular surgical treatment for proximal humeral fractures (PHF). This study aimed to assess the occurrence of complications in elderly patients with PHF treated surgically using ORIF with a locking plate and to investigate the potential differences between patients treated by shoulder surgeons and non-shoulder surgeons. Methods: A retrospective study was conducted using a single-center database to identify patients aged ≥70 years who underwent ORIF for PHF between January 1, 2011, and December 31, 2021. Data on the Neer classification, follow-up, occurrence of avascular necrosis of the humeral head, implant failure, and revision surgery were also collected. Statistical analyses were performed to calculate the overall frequency of complications according to the Neer classification. Results: The rates of implant failure, avascular osteonecrosis, and revision surgery were 15.7%, 4.8%, and 15.7%, respectively. Complications were more common in patients with Neer three- and four-part fractures. Although the difference between surgeries performed by shoulder surgeons and non-shoulder surgeons did not reach statistical significance, the rate of complications and the need for revision surgery were nearly two-fold higher in the latter group. Conclusions: PHF are highly prevalent in the elderly population. However, the ORIF surgical approach, as demonstrated in this study, is associated with a considerable rate of complications. Surgeries performed by non-shoulder surgeons had a higher rate of complications and a more frequent need for revision surgery. Future studies comparing surgical treatments and their respective complication rates are crucial to determine the optimal therapeutic options. Level of evidence: III.

Internal Defect Minimization of Die Cast Impeller Blade Using Taguchi's Design of Experiment (다구치 실험계획법을 이용한 임펠러 블레이드 다이캐스팅의 내부 결함 최소화)

  • Kim, D.;Choo, I.H.;Lee, Y.S.;Kim, S.W.
    • Transactions of Materials Processing
    • /
    • v.19 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • A die cast impeller blade has been developed in the effort on cost reduction in marine equipment industry. The purpose of this work is to optimize the die casting process using Taguchi's design of experiment for minimizing the internal defect of the die cast impeller blade. The experiments were preformed using the numerical simulation based on the L18 orthogonal array. As a results, the internal defect size of the die cast impeller blade for optimal design was controlled less than 1mm.

A Study on the Machining Characteristics by the Internal Quality of Heat Resisting Steel (내열강의 내부품질에 따른 절삭가공 특성에 관한 연구)

  • 채왕석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.24-29
    • /
    • 2000
  • This paper is experimental study of machining characteristics about martensitic heat resisting steel STR11. Machining characteristics are different according to internal quality(chemical compositions, microscopic structure and nonmetallic inclusion) mechanical properties(tensile strength value impact value and hardness) and dynamic cutting force. Following are the results : 1. In analyzing internal quality test materials have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness are larger. But values of elongation and impact values are smaller. Fracture surface of tensile specimen is ductile. 3, Cutting force is decreasing with cutting speed increasing 4. Cutting force is increasing with feed speed increasing.

  • PDF

Design of MYNAMIC CMOS ARRAY LOGIC (DYNAMIC CMOS ARRAY LOGIC의 설계)

  • 한석붕;임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.10
    • /
    • pp.1606-1616
    • /
    • 1989
  • In this paper, the design of DYNAMIC CMOS ARRAY LOGIC which has both advantages of dynamic CMOS and array logic circuits is proposed. The major components of DYNAMIC CMOS ARRAY LOGIC are two-stage dunamic CMOS circuits and an internal clock generator. The function block of dynamic CMOS circuits is realized as a parallel interconnection of NMOS transistors. Therefore the operating speed of DYNAMIC CMOS ARRAY LOGIC is much faster than the one of the conventional dynamic CMOS PLAs and static CMOS PLA. Also, the charge redistribution problem by internl delay is solved. The internal clock generator generates four internal clocks that drive all the dynamic CMOS circuits. During evaluation, two clocks of them are delayed as compared with others. Therefore the race problem is completoly eliminated. The internal clock generator also prevents the reduction of circuit output voltage and noise margin due to leakage current and charge coupling without any penalty in circuit operating speed or chip area utilization.

  • PDF

A Study on the Internal Quality and the Machining Characteristics of Martensitic Heat Resisting Steel (마르텐사이트계 내열강의 금속 및 기계적 특성에 관한 연구)

  • 채왕석;권용기;김동현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.1073-1077
    • /
    • 1997
  • In this paper, we have studied internal quality including chemical compositions, microscopic structure and nonmetalic inclusion of test materials. We have analyzed machining characteristics including tensile strength value, impact value, hardness value etcs. Test materials are usd martensitic heat resisting steel, STR11 and STS420J2. The obtined results are as follows : 1. In analyzing internal quality, STR11 and STR420J2 have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness value are large STR11 than STS420J2. But elongation impact are smaller STR11 than STS420J2. 3. Fracture surface of tensile speciman is ductile in STR11 and STS420J2.

  • PDF

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

Incarcerated pericecal hernia: a rare form of the internal hernia

  • Kang, Sung Il
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.236-239
    • /
    • 2018
  • A pericecal hernia is a rare form of an internal hernia, which has been described in several case reports. We present a case of a 32-year-old woman who complained of vague abdominal pain a day prior to admission. Abdominal computed tomography revealed the presence of a pericecal hernia without bowel ischemia. The patient underwent manual hernia reduction and was discharged without complications. We describe this case in detail and provide a review of the pertinent literature.