• Title/Summary/Keyword: internal pressures

Search Result 229, Processing Time 0.028 seconds

Effect of liquid viscosity on internal flow and spray characteristics of Y-jet atomizers (액체 점도에 따른 Y-jet 노즐 내부 유동 및 분무 특성의 변화)

  • Song, Si-Hong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4053-4061
    • /
    • 1996
  • Internal flow characteristics within Y-jet atomizers and the local drop size distribution and cross-sectional averaged drop size at the outside were investigated with the liquid and air injection pressures, mixing port length of atomizers, and the liquid properties taken as parameters. To examine the effect of the liquid viscosity, glycerin-water mixtures were used in this study. The liquid viscosity plays only a minor role in determining the internal flow pattern and the spatial distribution shape of drops, but the drop sizes themselves generally increase with increasing of the liquid viscosity. An empirical correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results; the liquid discharge coefficient strongly depends on the liquid flow area at the mixing point which is proportional to the local volumetric quality(.betha.$_{Y}$), and the volumetric quality was included in the correlation. Regardless of the value of the liquid viscosity, the compressible flow through the gas port was well represented by the polytropic expansion process(k=1.2), and the mixing point pressure could be simply correlated to the aspect ratio( $l_{m}$/ $d_{m}$) of the mixing port and the air/liquid mass flow rate ratio( $W_{g}$/ $W_{f}$) as reported in the previous study.udy.udy.y.

Plantar Soft-tissue Stress states in standing: a Three-Dimensional Finite Element Foot Modeling Study

  • Chen, Wen-Ming;Lee, Peter Vee-Sin;Lee, Tae-Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.197-204
    • /
    • 2009
  • It bas been hypothesized that foot ulceration might be internally initiated. Current instruments which merely allow superficial estimate of plantar loading acting on the foot, severely limit the scope of many biomechanical/clinical studies on this issue. Recent studies have suggested that peak plantar pressure may be only 65% specific for the development of ulceration. These limitations are at least partially due to surface pressures not being representative of the complex mechanical stress developed inside the subcutaneous plantar soft-tissue, which are potentially more relevant for tissue breakdown. This study established a three-dimensional and nonlinear finite element model of a human foot complex with comprehensive skeletal and soft-tissue components capable of predicting both the external and internal stresses and deformations of the foot. The model was validated by experimental data of subject-specific plantar foot pressure measures. The stress analysis indicated the internal stresses doses were site-dependent and the observation found a change between 1.5 to 4.5 times the external stresses on the foot plantar surface. The results yielded insights into the internal loading conditions of the plantar soft-tissue, which is important in enhancing our knowledge on the causes of foot ulceration and related stress-induced tissue breakdown in diabetic foot.

Changes in Internal Pressure of Frozen Fruits by Freezing Methods (동결방법에 따른 냉동 과일의 내부압력 변화)

  • 정진웅;정승원;박기재
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.459-465
    • /
    • 2003
  • This study was carried out to investigate the changes in internal pressure according to various freezing methods, as basic research to protect the destruction of tissues when fruits and vegetables are frozen. The rate of weight loss, caused by the freezing of fruits and vegetables, was found to be the least (0.44∼1.38%) when the immersion freezing method was applied. The difference in the rate of weight loss was the highest when freezing methods were applied to watermelon, and the freezing rate of watermelon whose moisture contents were greater have relatively greater influence on the weight loss. The difference in internal pressures was the least and caused by the volume increase and decrease, when pear, apple, and melon were frozen using the immersion freezing method, while the diffeyence the greatest when the air-blast freezing method was used. As the freezing rate was greater, the internal pressure was less. However, the internal pressure of strawberry and watermelon was the greatest when the immersion freezing method was applied. Frozen without using the thermal equalizing method, the change in internal pressure of fruits was about 2 psig. In contrast, the internal pressure of watermelon applied with the thermal equalizing method was changed in a way similar to that of watermelon not applied with the method, but the former generated a certain level of internal pressure and maintained a significantly low level of internal pressure (about 1.3 psig). When thawed, the internal pressure of samples to which the thermal equalizing method was applied was less than that of what the thermal equalizing method was not applied to. In comparison with the application of multi-step thermal equalizing method, 3∼4 times of application of the thermal equalizing method to the freezing resulted in the decrease of fluctuation range of internal pressure.

Nonlinear transient analysis of FG pipe subjected to internal pressure and unsteady temperature in a natural gas facility

  • Soliman, Ahmed E.;Eltaher, Mohamed A.;Attia, Mohamed A.;Alshorbagy, Amal E.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.1
    • /
    • pp.85-96
    • /
    • 2018
  • This study investigates the response of functionally graded (FG) gas pipe under unsteady internal pressure and temperature. The pipe is proposed to be manufactured from FGMs rather than custom carbon steel, to reduce the erosion, corrosion, pressure surge and temperature variation effects caused by conveying of gases. The distribution of material graduations are obeying power and sigmoidal functions varying with the pipe thickness. The sigmoidal distribution is proposed for the 1st time in analysis of FG pipe structure. A Two-dimensional (2D) plane strain problem is proposed to model the pipe cross-section. The Fourier law is applied to describe the heat flux and temperature variation through the pipe thickness. The time variation of internal pressure is described by using exponential-harmonic function. The proposed problem is solved numerically by a two-dimensional (2D) plane strain finite element ABAQUS software. Nine-node isoparametric element is selected. The proposed model is verified with published results. The effects of material graduation, material function, temperature and internal pressures on the response of FG gas pipe are investigated. The coupled temperature and displacement FEM solution is used to find a solution for the stress displacement and temperature fields simultaneously because the thermal and mechanical solutions affected greatly by each other. The obtained results present the applicability of alternative FGM materials rather than classical A106Gr.B steel. According to proposed model and numerical results, the FGM pipe is more effective in natural gas application, especially in eliminating the corrosion, erosion and reduction of stresses.

Does the Mean Arterial Pressure Influence Mortality Rate in Patients with Acute Hypoxemic Respiratory Failure under Mechanical Ventilation?

  • Gjonbrataj, Juarda;Kim, Hyun Jung;Jung, Hye In;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • Background: In sepsis patients, target mean arterial pressures (MAPs) greater than 65 mm Hg are recommended. However, there is no such recommendation for patients receiving mechanical ventilation. We aimed to evaluate the influence of MAP over the first 24 hours after intensive care unit (ICU) admission on the mortality rate at 60 days post-admission in patients showing acute hypoxemic respiratory failure under mechanical ventilation. Methods: This prospective, multicenter study included 22 ICUs and compared the mortality and clinical outcomes in patients showing acute hypoxemic respiratory failure with high (75-90 mm Hg) and low (65-74.9 mm Hg) MAPs over the first 24 hours of admission to the ICU. Results: Of the 844 patients with acute hypoxemic respiratory failure, 338 had a sustained MAP of 65-90 mm Hg over the first 24 hours of admission to the ICU. At 60 days, the mortality rates in the low (26.2%) and high (24.5%) MAP groups were not significantly different. The ICU days, hospital days, and 60-day mortality rate did not differ between the groups. Conclusion: In the first 24 hours of ICU admission, MAP range between 65 and 90 mm Hg in patients with acute hypoxemic respiratory failure under mechanical ventilation may not cause significantly differences in 60-day mortality.

Study on the Structural and Mechanical Characteristics of ITO Films Deposited by Pulsed DC Magnetron Sputtering

  • Kang, Junyoung;Le, Anh Huy Tuan;Park, Hyeongsik;Kim, Yongjun;Yi, Junsin;Kim, Sunbo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.351-354
    • /
    • 2016
  • The mechanical properties of ITO films such as adhesion and internal stress are very important for the commercial application of solar cell devices. We report high quality pulsed DC magnetron sputtered ITO films deposited on silicon and glass substrates with low resistivity and high transmittance for various working pressures ranging from 0.96 to 3.0 mTorr. ITO films showed the lowest resistivity of $2.68{\times}10^{-4}{\Omega}{\cdot}cm$, high hall mobility of $46.89cm^2/V.s$, and high transmittance (>85%) for the ITO films deposited at a low working pressure of 0.99 mTorr. The ITO films deposited at a low working (0.96 mTorr) pressure had both amorphous and polycrystalline structures and were found to have compressive stress while the ITO films deposited at higher temperature than 0.99 mTorr was mixture of amorphous and polycrystalline and was found to have tensile stress.

Impact of Internal/External Diffusion on Gasification Reaction Rate Analysis of Coal Char in High Temperatures and Elevated pressures (고온/고압 조건에서의 석탄 촤 내부 및 외부 가스화 반응효과)

  • Kim, Gyeong-Min;Kim, Jin-Ho;Lisandy, Kevin Yohanes;Kim, Ryang-Gyoon;Kim, Gyu-Bo;Jeon, Chung-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.23-29
    • /
    • 2016
  • Reactivity of gasification defined by bouardard reaction is critical parameter in efficiency of the gasifier. In this study, char reactivity of the gasification was derived from the experiments using the intrinsic reaction kinetics model. Pressurized wire mesh heating reactor (PWMR) can produce high temperature and high pressure conditions up to 50 atm and 1750 K, respectively and PWMR was designed to evaluate the intrinsic reaction kinetics of $CO_2$ gasification. In this study, Kideco and KCH (sub-bituminous Indonesian coal) were pulverized and converted into char. Experiments used the PWMR were conducted and the conditions of the temperature and pressure were 1373~1673 K, 1~40 atm. To distinguish the pressure effect from high pressurized condition, internal and external effectiveness factors were considered. Finally, the intrinsic kinetics of the Kideco and KCH coal char were derived from $n^{th}$ order reaction rate equations.

Manufacturing Integral Safety Vents in Prismatic Lithium-ion Batteries (직사각형 리튬 이온 전지의 일체형 안전장치 제조 공정에 관한 연구)

  • Kim, J. H.;Lee, K. H.;Lim, Y. J.;Kim, B. M.
    • Transactions of Materials Processing
    • /
    • v.24 no.4
    • /
    • pp.293-298
    • /
    • 2015
  • A safety vent is crucial to protect its user from unpredictable explosions caused by increasing internal pressure of the lithium-ion batteries. In order to prevent the explosion of the battery, a safety vent rupture is required when the internal pressure reaches a critical value. In conventional manufacturing, the cap plate and the safety vent are fabricated separately and subsequently welded to each other. In the current study, a manufacturing process including a backward extrusion and coining process is suggested to produce an integral safety vent which also has the benefit of increasing production efficiency. FE simulations were conducted to predict the rupture pressure and to design the safety vent using a ductile fracture criterion and the element deletion method. The critical value, C, in the ductile fracture criterion was obtained from uniaxial tensile tests with an annealed sheet of 1050-H14 aluminum alloy. Rupture tests were preformed to measure the rupture pressure of the safety vent. The results met the required rupture pressure within 8.5±0.5 kgf/cm2. The simulation results were compared with experimental results, which showed that the predicted rupture pressures are in good agreement with experimentally measured ones with a maximum error of only 3.9%.

Performance characteristic investigation and stay vane effect on Ns100 inline francis turbine

  • Singh, Patrick Mark;Chen, Zhenmu;Hwang, Yeong-Cheol;Kang, Min-Gu;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.397-402
    • /
    • 2016
  • This study presents the performance characteristics of a small Francis turbine with an inline casing and is a continuation of a previous study. A new runner design has been implemented using the previous facility. The specific speed of the new runner has been modified from $N_s$ 80 to $N_s$ $100m-kW-min^{-1}$. This turbine can be installed in a city water supply system. To dissipate excess pressures in the water line system an inline-turbine can be used instead of an inline-pressure reducing valve. Thus, some of the energy can be recovered by utilizing the pressure difference. For best applicability and minimal space consumption, the turbine is designed with an inline casing instead of a common spiral casing. As a characteristic of inline casing, the flow accesses to the runner are in the radial direction, showing low efficiency. The installation of vanes improves the internal flow and positively affects the output power. In contrast to the previous study, the new runner reduces the effect of the stay vanes by maintaining a higher efficiency.

Wind-induced tall building response: a time-domain approach

  • Simiu, Emil;Gabbai, Rene D.;Fritz, William P.
    • Wind and Structures
    • /
    • v.11 no.6
    • /
    • pp.427-440
    • /
    • 2008
  • Estimates of wind-induced wind effects on tall buildings are based largely on 1980s technology. Such estimates can vary significantly depending upon the wind engineering laboratory producing them. We describe an efficient database-assisted design (DAD) procedure allowing the realistic estimation of wind-induced internal forces with any mean recurrence interval in any individual member. The procedure makes use of (a) time series of directional aerodynamic pressures recorded simultaneously at typically hundreds of ports on the building surface, (b) directional wind climatological data, (c) micrometeorological modeling of ratios between wind speeds in open exposure and mean wind speeds at the top of the building, (d) a physically and probabilistically realistic aerodynamic/climatological interfacing model, and (e) modern computational resources for calculating internal forces and demand-to-capacity ratios for each member being designed. The procedure is applicable to tall buildings not susceptible to aeroelastic effects, and with sufficiently large dimensions to allow placement of the requisite pressure measurement tubes. The paper then addresses the issue of accounting explicitly for uncertainties in the factors that determine wind effects. Unlike for routine structures, for which simplifications inherent in standard provisions are acceptable, for tall buildings these uncertainties need to be considered with care, since over-simplified reliability estimates could defeat the purpose of ad-hoc wind tunnel tests.