• Title/Summary/Keyword: internal electrodes

Search Result 164, Processing Time 0.027 seconds

Modified regularized Newton-Raphson algorithm for Electrical Impedance Tomography in Region Of Interest

  • Nam, Il-Hwan;Kang, Byung-Chae;Kim, Ji-Hun;Choi, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.134-137
    • /
    • 2003
  • Newton-Raphson is most used algorithm in EIT(electrical impedance tomography), cross-sectional distribution of resistivity is reconstructed by mean of both generating and sensing electrodes attached onto the surface of the object. EIT has been suffered from the severe ill-posedness which is caused by the inherent low sensitivity of boundary measurements to any changes of internal resistivity values. In this paper, we propose modified cost function and weighting factor that compensate for low sensitivity between boundary measurements and internal resistivity and improve performance of Newton-Raphson for EIT in region of interest.

  • PDF

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Dielectric Breakdown Voltage and Dielectric Properties of High Voltage Mutilayer Ceramic Capacitor with C0G Temperature Coefficient Characteristics (C0G 온도계수 특성을 가지는 고압용 적층 칩 캐패시티의 유전 및 내전압 특성)

  • Yoon, Jung-Rag;Woo, Byong-Chul;Chung, Tae-Serk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • High voltage MLCCs with C0G temperature coefficient characteristics could apply DC-DC invertor were investigated for its dielectric properties. Also we manufactured MLCC through various process and studied the characteristics of dielectric break down voltage [BDV] and dielectric property as the variation of thickness in the green sheet and how to pattern the internal electrode. As the thickness of green sheet is increase, the dielectric BDV per unit thickness is decreased. But as the pattern of internal electrodes were floated we could manufacture the high voltage MLCC maintained its dielectric BDV a unit.

ELECTRICAL IMPEDANCE IMAGING FOR SEARCHING ANOMALIES

  • Ohin Kwon;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • Communications of the Korean Mathematical Society
    • /
    • v.16 no.3
    • /
    • pp.459-485
    • /
    • 2001
  • The aim of EIT (electrical impedance tomography) system is to image cross-section conductivity distribution of a human body by means of both generating and sensing electrodes attached on to the surface of the body, where currents are injected and voltages are measured. EIT has been suffered from the severe ill-posedness which is caused by the inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. With a limited set of current-to-voltage data, figuring out full structure of the conductivity distribution could be extremely difficult at present time, so it could be worthwhile to extract some necessary partial information of the internal conductivity. We try to extract some key patterns of current-to-voltage data that furnish some core information on the conductivity distribution such s location and size. This overview provides our recent observation on the location search and the size estimation.

  • PDF

Image Reconstruction using Modified Iterative Landweber Method in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 수정된 반복 Landweber 방법을 이용한 영상 복원)

  • Kim, Bong-Seok;Kim, Ji-Hoon;Kim, Sin;Kim, Kyung-Youn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.36-44
    • /
    • 2012
  • Electrical impedance tomography is a relatively new imaging modality in which the internal conductivity (or resistivity) distribution of a object is reconstructed based on the injected currents and measured voltages through the electrodes placed on the surface of the object. In this paper, it is assumed that the relationship between the resistivity distribution and the resistance of electrodes is linear. From this linear relation, the weighting matrix can be obtained and modified iterative Landweber method is applied to estimate the internal resistivity distribution. Additionally, to accelerate the convergence rate and improve the spatial resolution of the reconstructed image, optimal step lengths for the iterative Landweber method are computed from the objective function in the least-square sense. The numerical experiments have been performed to illustrate the superior reconstruction performance of the proposed scheme.

Characterization of Photoelectron Behavior of Working Electrodes with the Titanium Dioxide Window Layer in Dye-sensitized Solar Cells

  • Gong, Jaeseok;Choi, Yoonsoo;Lim, Yeongjin;Choi, Hyonkwang;Jeon, Minhyon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.346.1-346.1
    • /
    • 2014
  • Porous nano crystalline $TiO_2$ is currently used as a working electrode in a dye-sensitized solar cell (DSSC). The conventional working electrode is comprised of absorption layer (particle size:~20 nm) and scattering layer (particle size:~300 nm). We inserted window layer with 10 nm particle size in order to increase transmittance and specific surface area of $TiO_2$. The electrochemical impedance spectroscope analysis was conducted to analysis characterization of the electronic behavior. The Bode phase plot and Nyquist plot were interpreted to confirm the internal resistance caused by the insertion of window layer and carrier lifetime. The photocurrent that occurred in working electrode, which is caused by rise in specific surface area, increased. Accordingly, it was found that insertion of window layer in the working electrode lead to not only effectively transmitting the light, but also increasing of specific surface area. Therefore, it was concluded that insertion of window layer contributes to high conversion efficiency of DSSCs.

  • PDF

Ozone Generation Synergy Effects of Three-Phase Voltage Apply Type Superposed Discharge Ozonizer (3상 전압인가형 중첩방전 오존발생기의 오존생성 상승효과)

  • Lee, Byeong-Jun;Lee, Sang-Geun;Song, Hyeon-Jik;Kim, Yeong-Hun;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.468-476
    • /
    • 2000
  • Nowadays, ozone is mainly utilized for water treatment and home equipments. Although the demand for ozone is increasing, the ozone yield of silent discharge type ozonizer is low. Therefore, it is expected to improve the energy efficiency and ozone yield of an ozonizer. In this paper, a new ozone generation system is proposed. The 60[Hz] three-phase voltage is applied to three-phase superposed discharge type ozonizer(3PSDO) which has three electrodes(central, internal and external electrodes). There is no discharge pause time when three-phase voltage is applied due to 120-degree phase difference of applied voltage. The synergy effect of the three-phase superposed discharge type ozonizer is investigated by comparing with the three sort of single-phase discharge type ozonizer(1PDO). So, three-phase superposed discharge type ozonizer is able to obtain high ozone yield, and optimize discharge space, because this can increase the discharge power at low applied voltage.

  • PDF

The Capacitive Deionization Module Design and Its Analysis by Computational Flow Dynamics (CDI 모듈 설계와 전산유동해석)

  • Nam, Ki Jin;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.29 no.5
    • /
    • pp.284-291
    • /
    • 2019
  • In this study, for the improvement of flow pattern with the CDI module that had the larger electrodes, it was designed with the rectangular type which is gradually wider from the inlet. Based on this, both the flow pattern of feed solution and dead zone were observed and the internal pressure, streaming line and velocity vector distribution were analyzed through the computational flow dynamics and compared with the experimental results. For all flow rates of 10, 20, 30 mL/min, there were no dead zones and the flow patterns were maintained constant. Therefore, it may be possible that the larger electrodes are applied to the CDI process.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage (3상 전압을 사용한 중첩방전형 오존발생기의 오존생성 및 방전잡음특성)

  • 전병준;송현직;김영훈;최상태;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2000
  • In this paper, an ozonizer, which can supply individual and superposed silent discharge using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode and External electrode) and 2 gaps (gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the flow rate of supplied gas (O2). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum value was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF