• 제목/요약/키워드: internal dissipation

검색결과 120건 처리시간 0.03초

바이오 텔레메-터용 CMOS Custom LSI 제작 (Fabrication of CMOS Custom LSI for Implantable Biotelemeter)

  • 서희돈;최세곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1305-1308
    • /
    • 1987
  • This paper presents a design of an optimized implantable biotelemetry system and the fabrication of custom CMOS LSI for implementing this system. The internal circuits of this system are fabricated on a single silicon chip with a size of $4{\times}5mm^2$. This LSI is designed and fabricated not only to get as small size and low power dissipation as possible, but also to have multiple function. Its main functions are to select one of implanted sensors and to accomplish ON - OFF power switching of an implanted battery by receiving appropriate Command signals and control signals fran external circuits. The internal system which was assembled on a bread-board using fabricated LSI chip is confirmed to work as designed. The total power dissipation of this interal system was $10.12{\mu}W$.

  • PDF

저밀도 폴리에틸렌을 위한 고전계 파형의 필름 두께의존성에 관한 연구 동향 (A Research Trend on Film Thickness Dependence of Ac High Feld for Low Density Polyethylene)

  • 정성찬;노정현;이주홍;황종선;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1988-1989
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Research on a novel shear lead damper: Experiment study and design method

  • Chong, Rong; Wenkai, Tian;Peng, Wang;Qingxuan, Shi
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.865-876
    • /
    • 2022
  • The slit members have lower strength and lower stiffness, which might lead to lower energy dissipation. In order to improve the seismic performance of the slit members, the paper proposes the shear lead damper, which has stable performance and small deformation energy dissipation capacity. Therefore, the shear lead damper can set in the vertical silts of the slit member to transmit the shear force and improve energy dissipation, which is suitable for the slit member. Initially, the symmetrical teeth-shaped lead damper was tested and analyzed. Then the staggered teeth-shaped lead dampers were developed and analyzed, based on the defect analysis and build improvements of the symmetrical specimen. Based on the parameter analysis, the main influence factors of hysteretic performance are the internal teeth, the steel baffles, and the width and length of damper. Finally, the theoretical analysis was presented on the hysteretic curve. And the skeleton curve and hysteresis path were identified. Based on the above theoretical analysis, the design method was proposed, including the damping force, the hysteresis model and the design recommendations.

유동해석을 활용한 DUT Shell의 최적 방열구조 설계 (Design of Optimal Thermal Structure for DUT Shell using Fluid Analysis)

  • 이정구;진병진;김용현;배영철
    • 한국전자통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.641-648
    • /
    • 2023
  • 최근 4차 산업 혁명 중에서 인공지능의 급성장은 반도체의 성능 향상 및 회로의 집적을 기반으로 진보하였다. 전자기기 및 장비의 내부에서 연산을 돕는 트랜지스터는 고도화 및 소형화 되어 가며 발열의 제어 및 방열의 효율 개선이 새로운 성능의 지표로 대두되었다. DUT(Device Under Test) Shell은 트랜지스터의 검수를 위하여 정격 전류를 인가한 후, 임의의 발열 지점에서 전원을 차단한 상태에서, 방열을 통하여 트랜지스터의 내구도를 평가하여 불량 트랜지스터를 검출하는 장비이다. DUT Shell은 장비 내부의 방열 구조에 따라 동시에 더 많은 트랜지스터를 테스트할 수 있기 때문에 방열 효율은 불량 트랜지스터 검출 효율과 직접적인 관계를 갖는다. 이에 본 논문에서는 DUT Shell의 방열 최적화를 위하여 배치구조의 다양한 방법을 제안하고 전산유체역학을 이용하여 최적의 DUT Shell의 다양한 변형과 열 해석을 제안하였다.

접속 속도 향상 및 전력소모를 줄인 위성용 접속회로 연구 (Research for the interface circuit to reduce static current and rising time)

  • 원주호;고형호
    • 한국위성정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.114-118
    • /
    • 2016
  • 인공위성은 다양한 제작사에서 공급하는 전장품들로 구성되는 시스템이다. 각 제작사에서는 각 제작사에서 사용하는 제작 이력 및 제작하는 위성 요구조건에 따라 다양한 내부전원을 사용하게 된다. 따라서 전장품마다 사용하는 내부전원이 다르기 때문에 전장품 사이의 접속요건에 대한 분석이 필수적이다. 접속요건에 대한 검증을 완화시키기 위해서 사용되는 회로가 Open Collector회로로, Open collector는 내부전원 차이에서 발생하는 문제를 완화시킬 수 있지만, 정전류에 의한 전력소모 증가 및 상승시간의 증가와 offset 전압 문제를 발생시킬 수 있다. 따라서 본 논문에서는 전력소모를 감소시키면서 빠른 반응시간을 얻기 위한 접속회로를 제안하고, 감소되는 전력 및 상승시간 감소를 분석한다.

적외선 열화상을 활용한 리튬 이온 ESS의 방열설계 성능평가에 관한 연구 (A Performance Evaluation of a Heat Dissipation Design for a Lithium-Ion Energy Storage System Using Infrared Thermal Imaging)

  • 김은지;이경일;김재열
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.105-110
    • /
    • 2020
  • The global battery market is rapidly growing due to the development of vehicles(EV) and wireless electronic products. In particular logistics robots, which hielp to produce EVs, have attracted much interest in research in Korea Because logistics sites and factories operate continuously for 24 hours, the technology that can dramatically increase the operation time of the logistics equipment is rapidly developing, and various high-level technologies are required for the batteries used in. for example, logistics robots. These required technologies include those that enable rapid battery charging as well wireless charging to charge batteries while moving. The development of these technologies, however, result in increasing explosions and topical accidents involving rapid charging batteries These accidents due to the thermal shock caused by the heat generated during the charging of the battery cell. In this study, a performance evaluation of a heat dissipation design using infrared thermal imaging was performed on an energy storage systrm(Ess) applied with an internal heat conduction cooling method using a heating plate.

내부 철골끼움골조 및 벽체형 마찰댐퍼(WFD)로 보강된 2층 철근콘크리트골조 내진성능에 대한 실험적 연구 (An Experimental Study on Seismic Performance of Two-story Reinforced Concrete Frames Retrofitted with Internal Steel Frame and Wall Type Friction Damper)

  • 유창기;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.64-72
    • /
    • 2022
  • 본 연구에서는 WFD(Wall Friction Damper)를 보강한 철근콘크리트 골조의 내진성능을 확인하기 위해 2층 철근콘크리트 골조 의 보강방법(무보강, 내부 H- 형철골과 WFD보강)을 주요 변수로 하였다. WFD 내진 보강 공법은 강도 향상과 에너지 소산 공법을 혼합한 것이다. WFD의 충분한 에너지 소산 이전에 보강재와 기존 구조물의 접합부에서 사전 파괴를 방지하기 위해 내부 H형 철골과 보 측면을 관통하는 케미컬 앵커를 사용하여 WFD를 설치하였다. 시험결과 OMF-N 시험체는 최대강도 발현 후 R/C 기둥의 전단력에 의한 취성파괴 양상을 보였다. OMF-ALL(H) 실험체는 핀칭 효과의 감소와 RC 기둥의 파손이 발생함을 보였다. 또한 OMF-ALL(H)의 최대 강도, 누적 에너지 소산 및 연성은 OMF-N의 경우 3.01배, 7.2배 및 1.72배 증가하였다. 그 결과 철근콘크리트 구조물에 시공한 WFD 내진 보강공법이 내진성능을 향상시키고 보강효과가 유효한 것으로 나타났다.

두 열적 단순계로 구성된 복합계의 열역학 (Thermodynamics of a composite system composed of two simple thermal systems)

  • 정평석;김수연
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.275-284
    • /
    • 1997
  • Thermodynamic behavior of a composite system which is composed of two simple thermal subsystems with constant heat capacities is analyzed, and several thermodynamic phenomena are investigated. The changes of the states and the potential work of the composite system are shown as the interaction between the subsystems in the composite system. The potential work is defined as the possible maximum available work from the composite system, and it is a thermodynamic property of the composite system. The decrease of the potential work is the same as the available work output from the composite system in reversible processes. The dissipation of available work is directly connected to the generation of entropy. The concepts of exergy and internal energy can be explained as a special case of the potential work.

인버터용 전해커패시터의 수명 추정 (Life Estimation of Electrolytic Capacitors for Inverters)

  • 이동춘;김형진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.338-346
    • /
    • 2001
  • In this paper, dc link currents for the three-phase diode rectifiers and PWM inverters are analyzed and an algorithm of estimating the life of dc link electrolytic capacitors using the analyzed ripple current is presented. Since the capacitor life is dependent on the operating temperature, the power dissipation in capacitors should be calculated. For this, the ESR(equivalent series resistance) model of the capacitor is derived and ripple currents through the capacitor are analyzed. Relating the power dissipation and the heat transfer equation, the internal operating temperature is calculated. Then, the capacitor life can be predicted by using Arrhenius's equation. An example for applications is given for the practical system.

  • PDF

다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작 (Manufacture of Custom IC and System for Multi-channel Biotelemeter)

  • 서희돈;박종대
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF