• 제목/요약/키워드: internal corrosion control

검색결과 24건 처리시간 0.023초

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제41권11호
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.

Fatigue Behavior of Prestressed Concrete Beams Using FRP Tendons (FRP 긴장재를 이용한 프리스트레스트 콘크리트 보의 피로 거동)

  • Kim, Kyoung-Nam;Park, Sang-Yeol;Kim, Chang-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • 제23권2호
    • /
    • pp.135-144
    • /
    • 2011
  • Recently, researches about fiber reinforced polymer (FRP) which has excellent durability, corrosion resistance, and tensile strength as a substitution material to steel tendon have been actively pursued. This study is performed to examine FRP tendon used prestressed beam's safety under service load. The specimen was a prestressed concrete beam with internal bonded FRP tendon. In order to compare the member fatigue capacity, a control specimen of a prestressed concrete beam with ordinary steel tendon was tested. A fatigue load was applied at a load range of 60%, 70%, and 80% of the 40% ultimate load, which was obtained though a static test. The fatigue load was applied as a 1~3 Hz sine wave with 4 point loading setup. Fatigue load with maximum 1 million cycles was applied. The specimen applied with a load ranging between 40~60% did not show a fatigue failure until 1 million cycles. However, it was found that horizontal cracks in the direction of tendons were found and bond force between the tendon and concrete was degraded as the load cycles increased. This fatigue study showed that the prestressed concrete beam using FRP tendon was safe under a fatigue load within a service load range. Fatigue strength of the specimen with FRP and steel tendon after 1 million cycles was 69.2% and 59.8% of the prestressed concrete beam's static strength, respectively.

Evaluation of bonding state of shotcrete lining using nondestructive testing methods - experimental analysis (비파괴 시험 기법을 이용한 숏크리트 배면 접착상태 평가에 관한 실험적 연구)

  • Song, Ki-Il;Cho, Gye-Chun;Chang, Seok-Bue;Hong, Eun-Soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제11권1호
    • /
    • pp.71-83
    • /
    • 2009
  • Shotcrete is an important primary support for tunnelling in rock. The quality control of shotcrete is a core issue in the safe construction and maintenance of tunnels. Although shotcrete may be applied well initially onto excavated rock surfaces, it is affected by blasting, rock deformation and shrinkage and can debond from the excavated surface, causing problems such as corrosion, buckling, fracturing and the creation of internal voids. This study suggests an effective non-destructive evaluation method of the tunnel shotcrete bonding state applied onto hard rocks using the impact-echo (IE) method and ground penetration radar (GPR). To verify previous numerical simulation results, experimental study carried out. Generally, the bonding state of shotcrete can be classified into void, debonded, and fully bonded. In the laboratory, three different bonding conditions were modeled. The signals obtained from the experimental IE tests were analyzed at the time domain, frequency domain, and time-frequency domain (i.e., the Short- Time Fourier transform). For all cases in the analyses, the experimental test results were in good agreement with the previous numerical simulation results, verifying this approach. Both the numerical and experimental results suggest that the bonding state of shotcrete can be evaluated through changes in the resonance frequency and geometric damping ratio in a frequency domain analysis, and through changes in the contour shape and correlation coefficient in a time-frequency analysis: as the bonding state worsens in hard rock condition, the autospectral density increases, the geometric damping ratio decreases, and the contour shape in the time-frequency domain has a long tail parallel to the time axis. The correlation coefficient can be effectively applied for a quantitative evaluation of bonding state of tunnel shotcrete. Finally, the bonding state of shotcrete can be successfully evaluated based on the process suggested in this study.

Detection and Control of Bacterial Diseases of Cultured Fishes in Korea (양식어류(養殖魚類)의 세균성질병(細菌性疾病)의 진단(診斷)과 대책(對策))

  • Chun, Seh-Kyu
    • Journal of fish pathology
    • /
    • 제1권1호
    • /
    • pp.5-30
    • /
    • 1988
  • This is a comprehensive study for considering the effective treatment and control program of bacterial disease occurring in common carp, israel carp, color carp, crucian carp, eel and tilapia by clarifying the causes, mechanism of infection and onset and the diagnostic criteria. As a first step, the authors investigated the external views, gross and histopathologic findings of diseased fish using 450 infected fishes obtained from various farmer of Korea. This infection was characterized by hyperemia, hemorrhage and swelling of body surface and fins, congestion of liver, spleen, kidney, inflammation of intestine, hemorrhagic inflammation of various tissues, and necrosis and ulcer of various tissues were accompanied in serious cases. Bacteriologically, Aeromonas hydrophila and Edwardsiella tarda were isoiated from these fishes. Particularly in the regular check on 222 eels, 177 strains were isolated as 29.94% of Aeromonas hydrophila, 48.58% of Edwardsiella tarda and 21.47% of Flexibacter columnaris. Hexibacter columnaris was isolated from corroded gill of eels. The identical disease was occurred by innoculating the isolated Aeromonas hydrophila and Edwardsiella tarda and the identical strains were isolated from infected experimental fishes. The eels which were diagnosed Aeromonas disease from Kwangju, Pusan accompanied hemorrhage, swelling of body surface and fins, inflammation of stomach and intestine containing mucous fluids mixed with the pathogens. Color carp and crucian carp which were innoculated with the isolated 5 strins of Aeromomas hydrorphil died within 3 or 4 days accompanying with the characteristics of Aeromonas disease. Edward disease was characterized by abscesses of body surface, pus formation with concentration on phagocytes. The size of absecsses increased with progression elf disease. There were also various abscesses at internal organ and white nodules appeared in kidney. Histologically, various progressive granuloma were examined without inflammation of intestine. Columnaris disease of eels showed no hemorrhage except slight white body color. In autopsy, most of internal organs appeared normal and there were no septic odors. The only character was corrosion of gills. In order to treat these bacterial diseases, infected fishes must bathe in 20ppm chloramphenicol or kanamycin solution for 1 hour. Besides, medication program in oral ingestion of 75mg/kg chloramphenicol per day continuing for 5 to 7 days. After injecting the formalin treated Aermonas hydrophila antigen into carp, relatively high agglutination titer showed between 3 weeks and 6 weeks. Though this titer decreased from that time, it was continued for 18 weeks. In the case of injecting the formalin treated Edwardsiella tarda antigen into tilapia, the titer also increased. But tilapia which were immersed in the suspension fluid of the formalin treated Edwardsiella tarda showed no increase of the titer.

  • PDF