• Title/Summary/Keyword: internal consistency

Search Result 1,004, Processing Time 0.024 seconds

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

Fecal Microbiota Transplantation via Commercial Oral Capsules for Chronic Enteropathies in Dogs and Cats

  • Min-Ok Ryu;Soh-Yeon Lee;Se-Hoon Kim;Hwa-Young Youn;Kyoung-Won Seo
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.150-156
    • /
    • 2024
  • This retrospective case series assessed the effectiveness of commercially available oral fecal microbiota transplantation (FMT) for treating chronic enteropathies in eight animals, five dogs, and three cats, between 2020 and 2023 at the Seoul National University Veterinary Medical Teaching Hospital. Chronic enteropathies, often resistant to conventional therapies, present a significant challenge in veterinary medicine. To assess oral capsule FMT's effectiveness (Doggybiome® one capsule daily for dogs and Kittybiome® one capsule daily for cats) as a universal adjunctive therapy for chronic enteropathies across species not responding to traditional treatments. This retrospective case series applied a uniform evaluation of gastrointestinal symptoms and treatment efficacy, utilizing established scoring systems (Canine Inflammatory Bowel Disease Activity Index [CIBDAI] and Canine Chronic Enteropathy Clinical Activity Index [CCECAI] for dogs, Feline Chronic Enteropathy Activity Index [FCEAI] for cats) before and one month after FMT. This approach ensured consistency in hypothesis testing across the study population. Results revealed significant improvements in clinical indices post-FMT, with notable reductions in the CIBDAI, CCECAI, and FCEAI scores (p < 0.05). Additionally, symptoms such as anorexia, lethargy, diarrhea, vomiting, and weight loss showed marked improvement, with normalization of appetite and activity levels observed in most cases. No adverse effects were reported, indicating the safety and tolerability of this treatment. This study highlights the potential of oral capsule FMT as a viable therapeutic option for dogs and cats with chronic enteropathies unresponsive to conventional treatments, providing a new avenue for clinical management. Further research is warranted to expand these findings and explore the microbiome changes associated with FMT in veterinary patients.

Sarcoidosis Presenting with Massive Pleural Effusion and Elevated Serum and Pleural Fluid Carbohydrate Antigen-125 Levels

  • Lee, In Seon;Kim, Sae Byul;Moon, Chan Soo;Jung, Sung Mo;Kim, Song Yee;Kim, Eun Young;Jung, Ji Ye;Kang, Young Ae;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Park, Moo Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.6
    • /
    • pp.320-324
    • /
    • 2012
  • A 55-year-old woman was admitted for an elevated serum carbohydrate antigen-125 (CA-125) level, and a left pleural effusion, which were detected at a routine health examination. Computed tomography of the chest was performed upon admission, revealing extensive bilateral paratracheal and mediastinal lymph node enlargement with a massive left-sided pleural effusion. Subsequent analysis of the pleural fluid demonstrated consistency with an exudate, no evidence of malignant cells, and a normal adenosine deaminase. However, the pleural fluid and serum CA-125 levels were 2,846.8 U/mL and 229.5 U/mL, respectively. A positron emission tomography did not reveal any primary focus of malignancy. Finally, a surgical mediastinoscopic biopsy of several mediastinal lymph nodes was performed, revealing non-necrotizing granulomas, consistent with sarcoidosis. After a month of treatment of prednisolone, the left pleural effusion had resolved, and after 2 months the serum CA-125 level was normalized.

Development and Standardization of Modified Self-Assessment Manikin for Emotional Valence and Arousal Manikin (정서가 및 각성수준에 대한 자가 평가 마네킹 척도개발 및 표준화)

  • Kang, Eun-Ho;Choi, Jeong-Eun;Ham, Byung-Joo;Seok, Jeong-Ho;Lee, Kyoung-Uk;Kim, Won;Lee, Seung-Hwan;Lim, Hyun-Kook;Park, Young-Min;Yang, Jong-Chul;Ahn, Meekyung;Lee, Jae Seon;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.7 no.2
    • /
    • pp.113-118
    • /
    • 2011
  • Objectives : The Self-Assessment Manikin (SAM) developed by Bradley and Lang is a non-verbal pictorial assessment tool that measures human emotion and has been widely used. However, the pictures in SAM have not been easy for Korean subjects to understand or relate to. The authors developed a new manikin (Emotional Valence and Arousal Manikin, EVAS) modeling it after Korean faces while modifying and standardizing the SAM. Methods : Forty-one healthy subjects participated in this study. They were asked to rate the emotional valence and level of arousal using both the SAM and EVAS after being exposed to pictures of facial expressions for affective neurosciences-Korean version. The internal consistency of the EVAS and the correlation between EVAS and SAM were examined. Resuts : Internal consistencies of the valence using the EVAS were from 0.63 (surprise) to 0.82 (happiness) and those of the arousal were from 0.90 to 0.95. Correlation coefficients of the valence and arousal between the SAM and EVAS were from 0.61 (both surprise and disgust) to 0.84 (neutral) and from 0.82 (sadness) to 0.94 (fear), respectively. Conclusions : We developed a new manikin (the EVAS) for the Korean population modifying and standardizing the SAM. The EVAS demonstrated a good internal consistency and validity. As such, it can be used in the field of human emotion research.

The Validity and Reliability of Communication Skills Attitude Scale (CSAS) for Nursing Students (간호대학생의 의사소통 태도 측정도구 타당도 및 신뢰도 검증)

  • Song, Mi-Ok;Yun, So-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.345-355
    • /
    • 2017
  • The purpose of this study was to examine the validity and reliability of the Communication Skills Attitude Scale, which is used to examine communication learning attitudes for domestic nursing students. Study subjects were 401 nursing students at two nursing college who completed the CSAS scale consisting of 26 items from June 1 to 15. Data were analyzed using exploratory factor analysis, confirmatory factor analysis, internal consistency with IBM Statistics SPSS 21.0, and the IBM Statistics AMOS 21.0 program. To verify the construction factor of the scale, exploratory factor analysis with varimax rotation was performed, resulting in four factors but confirmed positive and negative attitudes two factors with 19 items considering the construct of theory and interpretability. The internal structure of the scale was schematized using confirmatory factor analysis, and goodness of fit of the final research model was very appropriate as shown by ${\chi}^2=446.475$ (df=148, p<0.001), TLI=.90, CFI=.91, RMSEA=.07, SRMR=.05. The final scale consisted of 19 items and two factors based on the confirmatory factor analysis. Cronbach's ${\alpha}$ for final scale was .90, showing internal consistency. The CSAS is expected to be useful to monitor the effectiveness of multiple teaching strategies about communication for domestic nursing students.

The Validity and Reliability of Safety Competency Tool for Perioperative Nurses (수술실 간호사 안전역량 도구의 타당도 및 신뢰도 검증)

  • Song, Mi-Ok;Jang, Keum Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.345-356
    • /
    • 2016
  • The purpose of this study was to develop a scale to evaluate the safety competency of perioperative nurses and to examine its validity and reliability. The research process included the development of preliminary items through literature reviews and the construct validity examination of the conceptual framework for the preliminary scale. The content validity of the identified items was evaluated by experts, resulting in 30 preliminary items. The participants involved in testing the validity and reliability of the preliminary scale were 377 perioperative nurses. The data were analyzed using exploratory factor analysis, parallel analysis, confirmatory factor analysis, and internal consistency. To verify the construction factor of the preliminary scale, exploratory factor analysis and parallel analysis were performed, resulting in 3 factors and 27 items. The internal structure of the scale was schematized using confirmatory factor analysis and the goodness of fit of the final research model was very appropriate, as shown by the values of TLI=.90, CFI=.91, RMSEA=.07, and SRMR=.07. The final scale consisted of 27 items and 3 factors including knowledge (6 items), skill (13 items), and attitude (8 items). Cronbach' ${\alpha}$ for the final scale was .94, showing good internal consistency. This safety competency scale can be used for assessing the competency of perioperative nurses regarding patient safety, for developing patient safety studies and for the career development of perioperative nurses.

Development and Psychometric Assessment of a Self-evaluation Questionnaire for Gastroesophageal Reflux Disease

  • Jung, Hye-kyung;Choi, Myung-Gyu;Baek, Myung-Ki;Wu, Justin CY
    • Journal of Neurogastroenterology and Motility
    • /
    • v.24 no.4
    • /
    • pp.584-592
    • /
    • 2018
  • Background/Aims There is uncertainty about how to measure outcomes reported by patients in gastroesophageal reflux disease (GERD). This study was conducted to develop an instrument and to determine of the definition of respondent for a patient reported outcomes to assess the efficacy of a treatment used for GERD treatment. Methods A structural process has developed a self-evaluation questionnaire for GERD (SEQ-GERD); health-related quality of life questionnaire for GERD (GERD-QOL) was translated through cross-cultural validation. Two-week reproducibility was evaluated and construct validity was assessed by correlating the SEQ-GERD with the Patient Assessment of Gastrointestinal Disorders (PAGI-SYM), the reflux disease questionnaire (RDQ), and GERD-QOL. Changes in SEQ-GERD scores were compared to assess the discriminative validity following 4 weeks of proton pump inhibitor administration. Results A total of 83 Korean patients were included (mean age $46{\pm}14$ years, females 61.4%). The internal consistency of the 19-item SEQ-GERD was good (alpha = 0.60-0.94) and the test-retest reliability was high (intra-class correlation coefficient = 0.67-0.95). The SEQ-GERD highly correlated with the GERD domain of the PAGI-SYM (correlation coefficient r = 0.894, P < 0.001), the RDQ-GERD (r = 0.877, P < 0.001), and GERD-QOL (r = -0.536, P < 0.05). SEQ-GERD scores significantly varied according to the overall treatment effectiveness scale of drug responsiveness and significantly decreased after drug treatment (mean differences according to the overall treatment effectiveness scale, P = 0.020). Conclusion This study supports that SEQ-GERD is reliable and valid, and can be used to evaluate the treatment response in patients with GERD.

The Effect of Non-cognitive Skill on Employability: Focusing on the Period of Job Search and Tenure (비인지적 요인이 취업에 미치는 영향: 구직기간과 근속기간 분석을 중심으로)

  • Lim, Chan-young
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.3069-3085
    • /
    • 2018
  • In this study, we examined the effect of non-cognitive factors on job tenure and tenure using KLIPS. We examine the internal consistency of the big5 personality trait and of the locus of control, and use the parameterized proportional hazards model. As a result, we confirmed that non-cognitive skill such as personality traits and locus of control affect individual labor market performance. Conscientiousness has shown that the job seeking period of adult job seekers is lengthened, thereby lowering the unemployment rate. It can be understood that high attentiveness under uncertainty can misinterpret information, and that lack of decision restricts escape from unemployment. In the tenure analysis, people with internal locus of control tendency were less likely to leave the job due to longer tenure. Those who have internal control can not only be preferred by the organization but also the internal control tendency seems to be the factor that maintains the long-term job because of the motivation and self-control of their actions.

Interference of Acoustic Signals Due to Internal Waves in Shallow Water

  • Na, Young-Nam;Jurng, Mun-Sub;Taebo Shim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3E
    • /
    • pp.9-20
    • /
    • 1999
  • To investigate the characteristics of internal waves (IWs) and their effects on acoustic wave propagation, a series of sea experiment were performed in the east coast of Donghae city, Korea in 1997 and 1998 where the water depth varies between 130 and 140 m. Thermistor strings were deployed to measure water temperatures simultaneously at 9 depths. CW source signals with the frequencies of 250,670 and 1000 Hz were received by an array of 15 hydrophones. Through the Wavelet transform analysis, the IWs are characterized as having typical periods of 2-17 min and duration of 1-2 hours. The IWs exist in a group of periods rather than in one period. Underwater acoustic signals also show obvious energy peaks in the periods of less than 12 min. Consistency in the periods of the two physical processes implies that acoustic waves react to the IWs through some mechanisms like mode interference and travel time fluctuation. Based on the thermistor string data, mode arriving structures are analyzed. As thermocline depth varies with time, it may cause travel time difference as much as 4-10 ms between mode 1 and 2 over 10 km range. This travel time difference causes interference among modes and thus fluctuation from range-independent stratified ocean structure. In real situations, however, there exist additional spatial variation of IWs. Model simulations with all modes and simple IWs show clear responses of acoustic signals to the IWs, i.e., fluctuations of amplitude and phase.

  • PDF

The effect of focus of attention by electroencephalogram-feedback on balance in young adults

  • Lee, Dong-Yeop;Choi, Won-Jae;Lee, Seung-Won
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2012
  • Objective: Electroencephalogram (EGG)-feedback is a training procedure aimed at altering brain activity, and is used as a treatment for disorders like attention. The purpose of this study was to determine the effects of external focus of attention by EGG-feedback on balance in young adults. Design: Cross-sectional study. Methods: Subject were students in Sahmyook University. Fifty young adults in their twenties and thirties. Subjects were performed both with and without external focus of attention by EEG-feedback on the posture of standing and tandem standing. Participants were educated effort to maintain static posture when they were under internal focus of attention. Good Balance System was used for measurement of postural consistency upon the following force platforms. Results: Body sway decreased significantly both normal standing and tandem standing with external focus of attention by EEG-feedback (p<0.05). Conclusions: The results demonstrate that the benefits of an external attentional focus are generalizable to young adults. The external focus of attention outperformed the internal focus of attention on the postural balance (p<0.05). It is showed that external focus of attention significant effects on balance by revoked automatic postural control of movement. Furthermore balance might be improved by training with an external focus. Further study is required to develop for training as a method of preventing fall in elderly peoples.

  • PDF