• 제목/요약/키워드: intermediate moment resisting frame

검색결과 16건 처리시간 0.018초

비선형동적해석을 통한 건식 기계적이음을 갖는 프리캐스트 모멘트 골조의 동등성 평가 (Evaluation of Emulative Level for Precast Moment Frame Systems with Dry Mechanical Splices by Using Nonlinear Dynamic Analysis)

  • 김선훈;이원준;이득행
    • 한국지진공학회논문집
    • /
    • 제28권2호
    • /
    • pp.85-92
    • /
    • 2024
  • This study presents code-compliant seismic details by addressing dry mechanical splices for precast concrete (PC) beam-column connections in the ACI 318-19 code. To this end, critical observations of previous test results on precast beam-column connection specimens with the proposed seismic detail are briefly reported in this study, along with a typical reinforced concrete (RC) monolithic connection. On this basis, nonlinear dynamic models were developed to verify seismic responses of the PC emulative moment-resisting frame systems. As the current design code allows only the emulative design approach, this study aims at identifying the seismic performances of PC moment frame systems depending on their emulative levels, for which two extreme cases were intentionally chosen as the non-emulative (unbonded self-centering with marginal energy dissipation) and fully-emulative connection details. Their corresponding hysteresis models were set by using commercial finite element analysis software. According to the current seismic design provisions, a typical five-story building was designed as a target PC building. Subsequently, nonlinear dynamic time history analyses were performed with seven ground motions to investigate the impact of emulation level or hysteresis models (i.e., energy dissipation performance) on system responses between the emulative and non-emulative PC moment frames. The analytical results showed that both the base shear and story drift ratio were substantially reduced in the emulative system compared to that of the non-emulative one, and it indicates the importance of the code-compliant (i.e., emulative) connection details on the seismic performance of the precast building.

RBS-B 접합부 설계식 개선에 따른 철골모멘트골조 시스템의 내진성능평가 (Seismic Performance Evaluation of Steel Moment Resisting Frame Systems According to an Improved Design Method of RBS-B Connections)

  • 한상환;강기병;문기훈;황성훈
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.75-84
    • /
    • 2010
  • 현행 내진설계기준에서 RBS-B 접합부는 오직 중간모켄트골조(IMF) 시스템에서만 사용이 허용된다. 본 연구는 현행설계규준에 따라 설계한 RBS-B 접합부를 갖는 철골 모멘트골조 시스템의 내진성능평가를 수행하였다. 이를 위하여 층수(3층, 6층, 9층), 경간너비(6m, 9m), 내진설계범주(SDC $C_{max}$, SDC $C_{min}$)으로 구성된 12개의 RBS-B접합부를 갖는 철골모멘트골조 건물을 설계하였고 RBS-B 접합부의 비선형 이력거동을 잘 모사하는 접합부 모델을 개발하였다. 설계된 대상골조는 ATC-63에 의해 개발된 내진성능평가방법에 따라 내진성능평가를 수행하였다. 또한 본 연구는 저자가 이전연구에서 제안한 새로운 설계법에 따라 설계된 IMF 시스템의 내진성능평가를 수행하였다. 그 결과 현행규준에 따라 설계한 몇 개의 대상골조가 적절한 붕괴여유비를 보유하지 못하였다. 반면에 새로운 설계절차에 따라 설계된 대상골조는 적절한 붕괴여유비를 보유하였다.

Demand response modification factor for the investigation of inelastic response of base isolated structures

  • Cheraghi, Rashid Eddin;Izadifarda, Ramezan Ali
    • Earthquakes and Structures
    • /
    • 제5권1호
    • /
    • pp.23-48
    • /
    • 2013
  • In this study, the effect of flexibility of superstructures and nonlinear characteristics of LRB (Lead Rubber Bearing) isolator on inelastic response of base isolated structures is investigated. To demonstrate the intensity of damage in superstructures, demand response modification factor without the consideration of damping reduction factor, demand RI, is used and the N2 method is applied to compute this factor. To evaluate the influence of superstructure flexibility on inelastic response of base isolated structures, different steel intermediate moment resisting frames with different heights have been investigated. In lead rubber bearing, the rubber provides flexibility and the lead is the source of damping; variations of aforementioned characteristics are also investigated on inelastic response of superstructures. It is observed that an increase in height of superstructure leads to higher value of demand RI till 4-story frame but afterward this factor remains constant; in other words, an increase in height until 4-story frame causes more damage in the superstructure but after that superstructure's damage is equal to the 4-story frame's. The results demonstrate that the low value of second stiffness (rubber stiffness in LRBs) tends to show a significant decrease in demand RI. Increase in value of characteristic strength (yield strength of the lead in LRBs) leads to decrease in the demand RI.

N2 Method를 이용한 RC 중간모멘트 연성골조의 반응수정계수 및 내진성능 평가 (Estimation of R-factor and Seismic Performance for RC IMRFs using N2 Method)

  • 윤정배;이철호;최정욱;송진규
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.33-39
    • /
    • 2002
  • 반응수정계수는 구조물의 비탄성 거동을 설계에 반영하고 설계지진력 산정시 설계강도를 탄성범위 이내로 저감시키기 위한 목적으로 사용하고 있다. 그러나 설계코드에서 채택하고 있는 반응수정계수는 과거의 지진피해로부터 관찰된 보편적 구조성능에 기인한 경험치이므로, 주기에 따른 동적성능과 구조 시스템의 구성에 따른 내진성능을 정확히 대변하지 못하고 있다. 본 연구에서는 중간모멘트 연성골조를 대상으로 N2 Method를 이용하여 반응수정계수와 내진성능을 평가하였으며, 그 결과를 미국의 IBC 2000 코드와 비교하여 이론적 타당성을 검증하였다. 해석결과 코드에 제시된 반응수정계수와 잘 부합되는 것으로 나타났으나, 동일한 구조시스템의 경우에도 주기에 따라 비교적 큰 차이를 보였다. 성능목표에 따른 사용성 기준을 설정하여 IDI를 평가한 결과, 설계지진에 대한 성능목표가 건물에 대한 내진성능을 대변하기는 어려우며 PBD(Performance Based Design)에 의거한 합리적인 접근이 필요한 것으로 판단된다.

비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가 (Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis)

  • 신동현;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.9-20
    • /
    • 2014
  • 철골 중간모멘트골조는 강한 지반운동에 대하여 적합한 저항능력을 확보하기 위한 지진력저항시스템으로서 일반적으로 사용되고 있다. 하지만 국내의 대다수 중 저층 철골건축물은 내진설계가 도입되기 이전에 건설되었거나 현재의 내진설계기준의 요구조건을 준수하지 않은 것들로, 이러한 건물들이 가지는 내진성능에는 의문점이 존재한다. 이와 같은 문제점의 인식에 기반하여 본 연구에서는 국내 철골 중간 모멘트골조의 내진성능에 대한 정량적 제시를 목표로 우선 층수 종류, 지진에 대한 보유내력, 부재 연성도, 제진장치의 유무를 변수로 하여 표본 건물을 설계하였다. 표본 건물의 내진 성능과 붕괴 매커니즘은 비선형 정적해석과 증분동적해석으로부터 획득한 붕괴여유비와 붕괴확률을 이용하여 분석하였다. 해석결과를 통하여 현행 국내기준에 따라 내진설계된 신축건물은 설계지진에 대해 충분한 내진성능을 가졌으며, 이에 반해 구조부재의 연성저감이 발생하거나 낮은 설계 밑면전단력에 대한 저항력을 가진 기존건물의 경우에는 높은 붕괴확률을 가지며 목표로 한 내진성능을 만족시키지 못하는 것으로 나타났다. 이와 같은 내진성능을 충족시키지 못하는 내진설계 도입 이전의 건물에 대해서 에너지 소산장치를 통해 보강하게 되면 장치의 에너지 소산능력뿐만 아니라 소성힌지의 재분배를 통해 붕괴확률 및 내진성능이 신축건물 수준으로 향상되었다.

면외방향 어긋난 보를 갖는 철골모멘트골조의 접합부 성능 (Connection Performance of Steel Moment Frame with Out-of-Plane Beam Skew)

  • 홍종국
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권2호
    • /
    • pp.84-91
    • /
    • 2022
  • 본 연구에서는 국내 내진설계기준에 의해 중간모멘트골조로 설계된 철골 모멘트접합부에서 면외방향 어긋남을 갖는 보가 접합부의 거동에 미치는 영향을 평가하였다. 기둥을 중심으로 보가 접합되는 형식에 따라 2가지 경우(단면접합 및 양면접합)와 각각의 경우에 대하여 4개 수준의 어긋남 각도(0°, 10°, 20°, 30°)를 조합하여 총 14개의 유한요소해석 모델을 구성하였다. 해석결과, 면외 어긋남을 갖는 대상 모멘트접합부는 국내 구조기준에 따른 중간모멘트골조의 성능수준을 만족하는 것으로 나타났다. 그러나, 면외 어긋남 각도가 커질수록 접합부 시스템의 하중저항능력이 감소하였다. 면외 어긋남 각도가 30°인 접합부에서 보-기둥이 직교된 접합부에 비하여 최대 하중은 약 13% 감소하였고, 층간 변위각 0.02 rad까지의 에너지 소산능력은 최대 26% 감소하였다. 또한, 어긋남 형상에 기인하여 접합부와 인접한 보 플랜지에서 응력이 비대칭으로 분포되며, 보 플랜지와 기둥 플랜지가 예각을 이루는 내측 플랜지(Inner Flange)에 응력이 집중되었다. 본 연구에서 고려한 보-기둥 접합에서는 어긋난 보에 의해 기둥의 축방향 회전에 미치는 영향은 미미하여 무시할 만 하였다.