• Title/Summary/Keyword: interference measurement

Search Result 614, Processing Time 0.028 seconds

Modeling of Propagation Interference and Channel Application Solution Suggestion In the UHF Band RFID Propagation Path (UHF 대역 RFID 전파경로에서의 전파간섭 모델링 및 채널 운용 방안 제안)

  • Moon, Young-Joo;Yeo, Seon-Mi;Jeon, Bu-Won;Roh, Hyoung-Hwan;Joung, Myoung-Sub;Oh, Ha-Ryoung;Seong, Yeong-Rak;Park, Jun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2047-2053
    • /
    • 2008
  • Auto-ID industries and their services have been improved since decades ago, and radio frequency identification (RFID) has been contributing in many applications. Product management can be the foremost example. In our industrial experiences, RFID in ultra high frequency (UHF) band provides much longer interrogation ranges than that of 13.56MHz; many more applications exist thereby. There should be several interesting and useful ideas on UHF RFID; however, those ideas can be limited due to the inevitable environmental circumstances that restrict the interrogation range in shorten value. This paper discusses the propagation interference among different types of readers (e.g, mobile RFID readers in stationary reader zone) in dense-reader environment. In most cases, UHF RFIDs in Korea will be dependent on the UHF mobile RFIDs. In this sense, the UHF mobile users accidently move into the stationary reader's interrogation zone. This is serious problem. In this paper, we analyze propagation loss and propose the effective channel allocation scheme that can contribute developing less-invasive UHF RFID networks. The simulation and practical measurement process using the commercial CAD tools and measurement equipments are presented.

3D Measurement of TSVs Using Low Numerical Aperture White-Light Scanning Interferometry

  • Jo, Taeyong;Kim, Seongryong;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.317-322
    • /
    • 2013
  • We have proposed and demonstrated a low numerical aperture technique to measure the depth of through silicon vias (TSVs) using white-light scanning interferometry. The high aspect ratio hole like TSV's was considered to be impossible to measure using conventional optical methods due to low visibility at the bottom of the hole. We assumed that the limitation of the measurement was caused by reflection attenuation in TSVs. A novel interference theory which takes the structural reflection attenuation into consideration was proposed and simulated. As a result, we figured out that the low visibility in the interference signal was caused by the unbalanced light intensity between the object and the reference mirror. Unbalanced light can be balanced using an aperture at the illumination optics. As a result of simulation and experiment, we figured out that the interference signal can be enhanced using the proposed technique. With the proposed optics, the depth of TSVs having an aspect ratio of 11.2 was measured in 5 seconds. The proposed method is expected to be an alternative method for 3-D inspection of TSVs.

INTERFERENCE CHARACTERISTICS OF CONSTRUCTION ENVIRONMENT FOR WSN APPLICATIONS

  • Sun-Chan Bae;Won-Sik Jang;Sang-Dae Park;Won-Suk Jang
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.592-595
    • /
    • 2013
  • Advent of Wireless Sensor Networks (WSN) has provided potentials to a variety of construction applications. It is well appreciated that WSNs have advantages over traditional wired system, such as ease of installation and maintenance with increased cost savings and efficiencies. However, the obstruction of wireless signal from physical objects in the heterogeneous construction environment often brings challenges to WSN measurement system. This paper analyzed the obstruction characteristic of construction environment where construction materials, equipment, and built structures obstruct the wireless signal yielding negative effect of measurement system. By adopting evaluation criteria, such as packet reception rate, field experiments have been implemented to quantitatively identify the interference of wireless signal from penetration, reflection, and network traffic under the construction environment. The results show that reliable performance of wireless sensor in construction environment depends on the optimal separation distance between a receiver and a transmitter, obstruction types, obstruction thickness, and transmission interval. In addition, the methodology and experimental results of this paper could be used in the practical design of network topology when hundreds of sensor nodes form a mesh network in the large scale construction applications.

  • PDF

A Study of Data Transmission Rate Measurement in 5 GHz Band Wireless LAN under the Influence of the Indoor Interference (5 GHz 대역 무선 랜의 실내 간섭 영향에 따른 데이터 전송률 측정 연구)

  • 송홍종;박유식;신용섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.5
    • /
    • pp.416-425
    • /
    • 2002
  • In this Paper, It is analysed 5 GHz frequency characteristics that carry out interference experimental under the indoor environments for understanding propagation interference between existing 5 GHz band wireless communication system and 5 GHz band wireless LAN system. The interference signal which was generated by signal generator injected to 5 GHz Wireless LAN communication system measured interference characteristics and This radio propagation main interference factors were classified received power level separation by interference source frequency and interference source frequency pulse period & width separation. It is measured transmission rate according to variable data and packet size for conforming the quality of 5 GHz band wireless LAN system. We measured the packet data loss rate and power level of received signal and analyzed its frequency characteristics effected by interference signal.

THE INFLUENCE OE BALANCING SIDE OCCLUSAL INTERFERENCE ON THE MASTICATORY MUSCLE ACTIVITY AND CONDYLAR PATH (균형측 교합장애가 저작근 활성도 및 과로에 미치는 영향에 관한 연구)

  • Jin, Tai-Ho;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.103-121
    • /
    • 1989
  • The purpose of this study was to investigate the influence of balancing interference on the activity of masticatory muscles and condylar path. Eight dental students of Won Kwang University without any symptoms of temporomandibular disorder and occlusal interferences, were selected for this study, The balancing interference was provided by construction and cementation of cast metal crowns on the upper and lower first molars. For the measurement of muscle activity, bioelectric processor (EM2, Myotronic Res., Inc., U.S.A.) was used and for the condular path, computerized electronic pantograph (Pantronics, Denar Corp., U.S.A.) was used and the myographic recordings were taken bilaterally from the anterior temporal, masseter and digastric muscles on rest position and on functions. These experimental procedures were done before cementation of experimental crown, three days after cementation of experimental crown, one week after, two weeks after and then one week after removal of experimental crown. The results are as follows: 1. The PRI score was increased at three days after application of balancing interference, and decreased at two weeks after. 2. Three subjects showed mild symptom of temporomandibular disorder at three or four days after application of interference, but the symptom was subsided in one or two weeks after application of interference. 3. One week after application of balancing interference, the activity of ipsilateral anterior temporal muscle in four subjects was decreased on gum chewing at experimental site. 4. Three days after application of balancing interference, the activity of ipsilateral anterior temporal muscle in three subjects was increased on gum chewing at non-experimental site. 5. The influence of balancing interference on the activity of anterior temporal, masseter and gigastric muscle was not prominent.

  • PDF

Optical Sensor Technology for Supervisory and Control of Electric Power System (전력 시스템 감시 제어용 광센서 기술)

  • Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2189-2191
    • /
    • 2000
  • Electric power systems are becoming advanced by using new technology year by year However, in electric power system environments. electromagnetic interference occurs in measurement, supervisory and control systems, especially in sensors. Optical sensor technologies are useful for solving the problem, since they are not affected by electromagnetic interference because they are composed of insulting materials. In this paper, some applications of optical sensor technology to electric power systems are introduced.

  • PDF

Measurement of Surface Temperature for Real Time Monitoring of the GMA Welding Processes (GMA용접공정의 실시간 모니터링을 위한 표면온도 측정)

  • 부광석;조형석
    • Proceedings of the KWS Conference
    • /
    • 1994.10a
    • /
    • pp.111-114
    • /
    • 1994
  • This paper describes a method to measure a weldment surface temperature for estimating variations of the weld pool size in the gas metal arc(GMA) welding processes. An Infrared sensing system is designed to measure the radiation emitted from the top surface of the weldment, The interference effect of the electric arc to the measurement is rejected by detecting the low peaks of the noisy signal. An optimizing criterion, in which the correlation between the weld quality and the measured temperature is maximized, is also proposed to determine the optimal measurement location.

  • PDF

A Broadband Reference Antenna to Measure an Electromagnetic Interference in the Range form 30MHz to 300MHz (30 MHz에서 300MHz 대역의 전자파 장해 즉정용 광대역 기준 안테나)

  • 조원서;황호정
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.417-423
    • /
    • 2000
  • A broadband antenna available in the range of 30MHz for electromagnetic interference (EMI) test is proposed in this paper, This antenna is configurated in a disk-loaded cylindrical dipole (DLCD) connected to an 180。 hybrid balun consisting of two coaxial feeders. The performance of EMI antenna is characterized with its accurate antenna factor. The antenna factor for this antenna is obtained by using the method of moments and the calculated results are compared with the measured ones. Normalized site attenuation (NSA) is also measured by using this antenna. The results present that the propose antenna could be used for a reference antenna having measurement reproducibility and represented by a theoretically accurate analysing model in EMI measurement.

  • PDF

Computer Simulation of Multiple Reflection Waves for Thickness Measurement by Ultrasonic Spectroscopy (초음파 Spectroscopy에 의한 두께측정을 위한 다중반사파의 시뮬레이션)

  • Park, I.G.;Han, E.K.;Choi, M.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 1992
  • Ultrasonic spectroscopy is likely to become a very powerful NDE method for detection of microfects and thickness measurement of thin film below the limit of ultrasonic distance resolution in the opaque materials, provides a useful information that cannot be obtained by a conventional ultrasonic measuring system. In this paper, we considered a thin film below the limit of ultrasonic distance resolution sandwitched between two substances as acoustical analysis model, demonstrated the usefulness of ultrasonic spectroscopic analysis technique using information of ultrasonic frequency for measurements of thin film thickness, regardless of interference phenomenon and phase reversion of ultrasonic waveform. By using frequency intervals(${\triangle}f$) of periodic minima from the ratio of reference power spectrum of reflective waveform obtained a sample to power spectrum of multiple reflective waves obtained interference phenomenon caused by ultrasonic waves reflected at the upper and lower surfaces of a thin layer, can measured even dimensions of interest are smaller than the ultrasonic wave length with simplicity and accuracy.

  • PDF

Measurement of Transient Electric Field Emission from a 245 kV Gas Insulated Substation Model during Switching

  • Rao, M. Mohana;Thomas, M. Joy;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.306-311
    • /
    • 2007
  • The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.