• Title/Summary/Keyword: interference evaluation

Search Result 461, Processing Time 0.024 seconds

A Performance Evaluation of MB-OFDM UWB System Considering the Domestic DAA Regulation (국내 DAA 기술 기준을 고려한 MB-OFDM UWB 성능 평가)

  • Shin, Cheol-Ho;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1000-1009
    • /
    • 2008
  • The purpose of this paper is to analyze the performance of MB-OFDM UWB system when the interference signal that can be WIMAX signal or 4 G system signal is received by detection limit of -80 dBm/MHz proposed in Korea for DAA(Detect And Avoid) to permit UWB in $3.1{\sim}4.8$ GHz. MB-OFDM UWB system supports two transmission modes; one is TFI(Time frequency Interleaving) mode that transmits OFDM symbols using different carrier frequency from symbol to symbol according to Time Frequency(TF) codes, the other is FFI(Fixed Frequency Interleaving) mode that transmits OFDM symbols using a specific carrier frequency. In this paper, we considered the TX average power and the synchronization structure to reflect the effect of frequency hopping according to TFC. Interference analysis results show that the WiMAX system is fenced thoroughly from UWB interference in domestic DAA regulation, but the performance of MB-OFDM UWB system is degraded seriously by an interference signal with the DAA detection limit even in frequency Hopping mode that can get frequency diversity effect.

Psycho-acoustic evaluation of the indoor noise in cabins of a naval vessel using a back-propagation neural network algorithm

  • Han, Hyung-Suk
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.374-385
    • /
    • 2012
  • The indoor noise of a ship is usually determined using the A-weighted sound pressure level. However, in order to better understand this phenomenon, evaluation parameters that more accurately reflect the human sense of hearing are required. To find the level of the satisfaction index of the noise inside a naval vessel such as "Loudness" and "Annoyance", psycho-acoustic evaluation of various sound recordings from the naval vessel was performed in a laboratory. The objective of this paper is to develop a single index of "Loudness" and "Annoyance" for noise inside a naval vessel according to a psycho-acoustic evaluation by using psychological responses such as Noise Rating (NR), Noise Criterion (NC), Room Criterion (RC), Preferred Speech Interference Level (PSIL) and loudness level. Additionally, in order to determine a single index of satisfaction for noise such as "Loudness" and "Annoyance", with respect to a human's sense of hearing, a back-propagation neural network is applied.

Performance Evaluation of Hybrid DS/SFH-CDMA Noncoherent MFSK Signal with Channel Coding and MRC Diversity Techniques in Mobile Communication Nakagami Fading Channels (이동통신 Nakagami 페이딩 채널에서 채널코딩과 최대비합성 다이버시티 기법에 의한 Hybrid DS / SFH-CDMA 비동기 MFSK 신호의 성능평가)

  • ;Norihiko Morinaga
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.342-353
    • /
    • 1997
  • This paper presents an analytical evaluation of a hybrid direct-sequence/slow frequencyhopped code division multiple-access (DS/SFH-CDMA) system employing noncoherent M-ary frequency shift keying(MFSK) modulation in a multiple Nakagami fading (m) environment. Multipath interference (MPI) and multi-access interference (MAI) is taken into account and the spectral efficiency is calculated for uncoded as well as channel coding systems. Predetection multipath maximal ratio combining (MRC) diversity in conjunction with interleaved channel coding (Hamming(7,4) code, BCH(15, 7) code and RS (7, 4), (15, 9)) code ) is employed for improving the bit error rate (BER) performance. The BER of noncoherent hybrid system is obtained using a Gaussian interference approximation.

  • PDF

Development of 3-Component tool Dynamometer for Evaluation of Machinability in High Speed Machining (고속가공에서 가공성 평가를 위한 3축 공구동력계 개발)

  • Kang, Myeong-Chang;Kim, Jeong-Suk;Lee, Deuk-Woo;Lee, Ki-Yong;Kim, Jeong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.11-18
    • /
    • 1999
  • Recently high speed machining is being studied actively to reduce machining time and to improve machining precision. To perform efficient high speed machining, evaluation of high speed machinability must be studied preferentially and it can be identified by investigation of cutting force. To measure cutting forces in high speed machining, dynamometer which has high natural frequency was newly designed using 3-axes piezo force sensor. For newly designed dynamometer, calibration is conducted with sensitivity of force sensor modulated and proper preload and interference force are investigated experimently. Also, cutting force signals of newly designed dynamometer are compared with those of conventional one in high speed cutting experiment and its superiority is confirmed. Then using newly designed dynamometer, high speed machinability is evaluated about cutting force and tool wear in various cutting conditions.

  • PDF

A Study on the Characteristics of Electronic Magnetic Interference(EMI) in Acoustic Emission Testing for Corrosion Detection of Ground Tank (지상탱크의 부식감지를 위한 음향방출시험에서 발생한 전자기간섭신호의 특성 연구)

  • Kim, Sung-Dai;Jung, Woo-Gwang
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.239-243
    • /
    • 2007
  • The evaluation and comparison have been made for the EMI noise which was included in the signal from the sensors in the acoustic emission testing for the bottom plate of ground tank at full. The EMI signal has been classified into two types. One is the signal with very short AE count, and this signal possibly can be filtered by front end filter setting of the channel count with low level of 4 and high level of $10^8$. The other EMI signal occurred from CH 1, CH 3 and CH 10, and had high and constant duration with high energy and count (maximun duration > $10^5\;{\mu}s$), and has characteristic gradient of accumulation amplitude distribution. This signal should be removed in the AE signal evaluation by filtering, because this may affect to the total gradient.

Sound Source Separation Using Interaural Intensity Difference in Closely Spaced Stereo Omnidirectional Microphones (인접 배치된 스테레오 무지향성 마이크로폰 환경에서 양이간 강도차를 활용한 음원 분리 기법)

  • Chun, Chan Jun;Jeong, Seok Hee;Kim, Hong Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.191-196
    • /
    • 2013
  • In this paper, the interaural intensity difference (IID)-based sounr source separation method in closely spaced stereo omnidirectional microphones is proposed. First, in order to improve the channel separability, a minimum variance distortionless response (MVDR) beamformer is employed to increase the intensity difference between stereo channels. After that, IID-based sound source separation method is applied. In order to evaluate the performance of the proposed method, source-to-distortion ratio (SDR), source-to-interference ratio (SIR), and sources-to-artifacts ratio (SAR), which are defined as objective evaluation criteria in stereo audio source separation evaluation campaign (SASSEC), are measured. As a result, it was shown from the objective evaluation that the proposed method outperforms a sound source separation method without applying a beamformer.

Study on the Performance of Wireless Local Area Network in a Multistory Environment with 8-PSK TCM

  • Suwattana, Danai;Santiyanon, Jakkapol;Laopetcharat, Thawan;Charoenwattanaporn, Monton;Goenchanart, Ut;Malisuwan, Settapong
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.549-551
    • /
    • 2002
  • A Wireless Local Area Network (WLAN) is a flexible data communication system implemented as an extension to, or as an alternative for, a wired LAN with in a building or campus. However, communications in an indoor environment present problems not encountered in outdoor wireless communication systems. Since cellular type systems are interference limited, the indoor environment is more hostile than the outdoor environment due to the lower propagation constant. In this paper, the equation for the signal to interference ratio in a multistory building will be derived. Knowing the S/I ratio, the floor frequency reuse can be determined. Finally, the simulation in this research is designed to study the performance (BER) of WLAN system in the multistory environment by applying the 8-PSK Trellis Coded modulation technique. The procedure allows a quick evaluation of BER in Wireless LAN system due to the co-channel interference.

  • PDF

Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction (전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Lee, Joong Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

Structural Integrity Evaluation for Interference-fit Flywheels in Reactor Coolant Pumps of Nuclear Power Plants

  • Park June-soo;Song Ha-cheol;Yoon Ki-seok;Choi Taek-sang;Park Jai-hak
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1988-1997
    • /
    • 2005
  • This study is concerned with structural integrity evaluations for the interference-fit flywheels in reactor coolant pumps (RCPs) of nuclear power plants. Stresses in the flywheel due to the shrinkage loads and centrifugal loads at the RCP normal operation speed, design overspeed and joint-release speed are obtained using the finite element method (FEM), where release of the deformation-controlled stresses as a result of structural interactions during rotation is considered. Fracture mechanics evaluations for a series of cracks assumed to exist in the flywheel are conducted, considering ductile (fatigue) and non-ductile fracture, and stress intensity factors are obtained for the cracks using the finite element alternating method (FEAM). From analysis results, it is found that fatigue crack growth rates calculated are negligible for smaller cracks. Meanwhile, the material resistance to non-ductile fracture in terms of the critical stress intensity factor (K$_{IC}$) and the nil-ductility transition reference temperature (RT$_{NDT}$) are governing factors for larger cracks.