• 제목/요약/키워드: interface parameters

검색결과 974건 처리시간 0.026초

TWO-LAYER MUTI-PARAMETERIZED SCHWARZ ALTERNATING METHOD FOR TWO-DIMENSIONAL PROBLEMS

  • Kim, Sang-Bae
    • Journal of applied mathematics & informatics
    • /
    • 제30권3_4호
    • /
    • pp.477-488
    • /
    • 2012
  • The convergence rate of a numerical procedure based on Schwarz Alternating Method(SAM) for solving elliptic boundary value problems depends on the selection of the interface conditions applied on the interior boundaries of the overlapping subdomains. It has been observed that the mixed interface condition, controlled by a parameter, can optimize SAM's convergence rate. In [8], one introduced the two-layer multi-parameterized SAM and determined the optimal values of the multi-parameters to produce the best convergence rate for one-dimensional elliptic boundary value problems. In this paper, we present a method which utilizes the one-dimensional result to get the optimal convergence rate for the two-dimensional problem.

Exoskeleton 형태의 모션 캡쳐 장치를 이용한 이동로봇의 원격 제어 (Teleoperated Control of a Mobile Robot Using an Exoskeleton-Type Motion Capturing Device Through Wireless Communication)

  • 전풍우;정슬
    • 제어로봇시스템학회논문지
    • /
    • 제10권5호
    • /
    • pp.434-441
    • /
    • 2004
  • In this paper, an exoskeleton-type motion capturing system is designed and implemented. The device is designed to have 12 degree-of-freedom entirely to represent human arm motions. Forward and inverse kinematics of the device are analyzed to make sure of its singular positions. With the designed model parameters, simulation studies are conducted to verify that the designed motion capturing system is effective to represent human motions within the workspace. As a counterpart of the exoskeleton system, a mobile robot is built to follow human motion restrictively. Experimental studies of teleoperation from the exoskeleton device to control the mobile robot are carried out to show feasible application of wireless man-machine interface.

Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation

  • Huynh, Thanh-Canh;Lee, Kwang-Suk;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.375-393
    • /
    • 2015
  • In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their performances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses.

전력케이블 접속재 XLPE/EPDM 계면의 부분방전 특성 (Partial Discharge Characteristics of the XLPE/EPDM Interface in Power Cable Joint)

  • 조경순;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.780-786
    • /
    • 2007
  • This paper describes the influence on partial discharge characteristics of defects at the model XLPE/EPDM interfaces of power cable joints. The defects of void and copper which could inadvertently be present at the joint interface. We measured ${\Phi}-n,\;{\Phi}-q$ patterns by a computer-aided partial discharge measuring system. Several parameters i, e, maximum discharge $q_{max}$ [pC], average discharge q [pC/cycle], and average angle of discharge ${\Theta}g$ [deg] were found to depend upon the defect type varying applied voltage. As the result of time evaluation, partial discharges are small different at copper defects, but is decreasing obviously about 20 minutes at void defect. It considered that difference of magnitude of total positive discharge of Q+ [pC] and total negative discharge of Q- [pC] is SPMD(swarming pulsive micro discharges).

쵸크랄스키 실리콘 단결정의 특성에 미치는 아르곤 유동의 영향 (Effect of argon flow on the quality of Czochralski silicon crystal)

  • 김정민;이홍우;최준영;유학도
    • 한국결정성장학회지
    • /
    • 제10권2호
    • /
    • pp.91-95
    • /
    • 2000
  • 8인치 쵸크랄스키 실리콘 단결성 성장에 있어서, 계면에서의 온도기울기, 산소, 농도 및, 반경방향의 산소농도 분포에 미치는 아르곤 가스 유동의 영향을 조사하였다. 아르곤의 유입량을 증가시킴에 따라 계면 근처 결정내 온도기울기가 증가하였으며. 결정내 산소농도는 감소하였다. 한편, 반경방향의 산소농도 균일성은 악화됨이 관찰되었다. 실험 결과를 종합하여 볼 때, 아르곤 유동이 산소 농도 및 균일 분포성 등의 결정 특성에 중요한 영향을 미치는 성장 공정변수임을 확인할 수 있었다.

  • PDF

TWO-LAYER MULTI-PARAMETERIZED SCHWARZ ALTERNATING METHOD FOR 3D-PROBLEM

  • KIM, SANG-BAE
    • Journal of applied mathematics & informatics
    • /
    • 제34권5_6호
    • /
    • pp.383-395
    • /
    • 2016
  • The convergence rate of a numerical procedure based on Schwarz Alternating Method (SAM) for solving elliptic boundary value problems depends on the selection of the interface conditions applied on the interior boundaries of the overlapping subdomains. It has been observed that the Robin condition (mixed interface condition), controlled by a parameter, can optimize SAM's convergence rate. In [8], one formulated the twolayer multi-parameterized SAM and determined the optimal values of the multi-parameters to produce the best convergence rate for one-dimensional elliptic boundary value problems. Two-dimensional implementation was presented in [10]. In this paper, we present an implementation for threedimensional problem.

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

다양한 형상의 마이크로 채널 내 밀도 차를 가진 다상 층류 유동의 특성에 대한 매개변수 연구 (Parametric Study on the Characteristics of Multiphase Laminar Flow with Density Difference in Various Microchannels)

  • 백승호;김동성;최영기
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.783-788
    • /
    • 2009
  • In this paper, we have performed a parametric study on the characteristics of multiphase laminar flow with density difference in various microchannels. The interface between multiphase fluids is rotated by the gravitational forces induced by density difference. The numerical simulations were carried out via commercial CFD package to study the characteristics of multiphase laminar flow. The results of the numerical simulations in this study were verified by comparing with the previously reported experimental results in the literature. We have also proposed a new dimensionless relationship between dimensionless rotation angle of interface and dimensionless parameters are proposed for square microchannels with various aspect ratios. The dimensionless relationship could be widely applied to the reliable design of various microfluidic devices dealing with multiphase laminar flow.

윈도우즈 GUI 환경을 이용한 자동차의 주행성능 측정.분석용 CAT 시스템의 개발 (Development of a CAT System for Measuring and Analysing the Ride and Handling Performances of Vehicle under Windows GUI Environment)

  • 양희구;김석일;김동룡;김건상
    • 한국자동차공학회논문집
    • /
    • 제5권4호
    • /
    • pp.21-28
    • /
    • 1997
  • The vehicle handling performances have a close relation with the driver's safety. And the CAT(Computer aided testing) system has been introduced as a powerful tool for improving the handling performances. In this study, a CAT system for effectively measuring and analysing the handling performances is developed based on the windows GUI(Graphic user interface) environment. Especially, in order to derive a lot of significant handling performance parameters from a series of proving ground tests, the CAT system has various functions related to real time measurement, time domain analysis, frequency domain analysis, steady state analysis and so on.

  • PDF

Plasma and VUV Pretreatments of Polymer Surfaces for Adhesion Promotion of Electroless Ni or Cu Films

  • Romand, M.;Charbonnier, M.;Goepfert, Y.
    • 접착 및 계면
    • /
    • 제4권2호
    • /
    • pp.10-20
    • /
    • 2003
  • This paper is relative to the electroless deposition of nickel or copper films on polyimide and polytetrafluoroethylene substrates. First, it is presented an original approach of the electroless process which consists in grafting nitrogenated functionalities on the polymer surfaces via plasma or VUV-assisted treatments operating in a nitrogen-based atmosphere ($NH_3$, $N_2$), and then in catalysing the grafted surfaces in an aqueous tin-free, Pd(+2)-based solution. Adhesion of the Pd(+2) catalytic species on polymer surfaces is explained by the formation of strong covalent bonds between these species and the grafted nitrogenated groups. Second, it is show how a fragmentation test performed in conjunction with electrical measurements can be used to characterize the practical adhesion of the electroless coatings deposited on flexible polymer substrates, and to evidence the influence of some experimental parameters (plasma treatment time and nature of the gas phase).

  • PDF